Langkau ke kandungan
Bahagian automasi, bekalan seluruh dunia
Langkau ke maklumat produk
1 daripada 3

SKU:FS-TSDI-1624C

Honeywell FS-TSDI-1624C 24V Safety Input FTA

Hanya tinggal 8 unit sahaja
  • Manufacturer: Honeywell

  • Product No.: FS-TSDI-1624C

  • Product Type: Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 200g

  • Shipping port: Xiamen

  • Warranty: 12 months

Polisi Pemulangan 30 Hari · Jaminan 12 Bulan
  • Penghantaran Pantas
  • Sokongan 24/7
  • Jaminan Kualiti

Penerangan

Product Overview

The FS-TSDI-1624C is a high-reliability Field Termination Assembly (FTA) module designed to interface between field wiring and the Honeywell Safety Manager system. This module provides 16 current-limited digital input channels specifically approved for routing non-incendive field circuits into Class I, Division 2 hazardous locations. 

Core Technical Advantages

Class I, Division 2 Hazardous Location Safety

Engineered with precise energy-limiting circuitry, this module restricts igniting current to less than 100 mA per channel under worst-case voltage conditions. This design allows direct interfacing with field devices located in explosive gas atmospheres without the need for additional bulky intrinsic safety barriers.

Dual-Group Fuse Protection

The 16 channels are divided into two isolated groups of 8. Each group features a high-voltage rated 250 mA SOC SHV12 ceramic fuse on the common positive line, preventing field-side short circuits from disabling the entire module and isolating faults effectively.

Redundant Module Compatibility

The hardware architecture natively accepts dual connection paths, allowing a single FTA block to drive a redundant pair of safety input cards simultaneously. This architecture eliminates single points of failure between the field termination and the safety logic layer.

Technical Specifications

Parameter Specification Details
Manufacturer Honeywell (Safety Manager)
Model Type FS-TSDI-1624C / FC-TSDI-1624C
Channel Configuration 16 Channels (2 Groups of 8)
Nominal Input Voltage 24 V DC (-15% to +30%)
Input Current Load ≤ 15 mA at 24 V DC (with Redundant Load)
Igniting Current Limit < 100 mA at 24 V DC +30% (per channel)
Fuse Rating / Model 250 mA, 400 V AC/DC (SOC SHV12)
Dimensions (L × W × H) 170 × 70 × 60 mm (6.69 × 2.76 × 2.36 in)

Class I Division 2 Loop Parameter Limits

To preserve non-incendive loop integrity, interconnected field wiring must comply strictly with the following electrical constraints:

  • Max. Closed Loop Resistance: 250 Ω
  • Min. Open Loop Resistance: 15 kΩ
  • Hydrogen Environments (Group A & B): Max. Inductance = 8 mH | Max. Capacitance = 0.3 μF
  • Non-Hydrogen Environments (Group C & D): Max. Inductance = 22 mH | Max. Capacitance = 7 μF

Installation and Maintenance

DIN Rail Mounting

Snap the module securely onto standard TS32 or TS35 DIN EN rails. The physical installation requires an absolute minimum rail length of 171 mm to guarantee stability and adequate side spacing inside the enclosure panel.

Field Connection Protocols

Connect field wires using copper conductors up to a maximum size of 2.5 mm² (AWG 14). Strip the wire insulation back exactly 7 mm (0.28 in). Secure the wire inside the terminal block by applying a precise tightening torque of 0.5 Nm (0.37 ft-lb) to avoid damage to the terminal frame.

Fuse Replacement Standards

If a group experiences a dead short circuit, verify loop integrity before replacing the fuse. Only use original manufacturer part numbers (SOC SHV12 250 mA) to maintain the certified non-incendive thermal thresholds. Note that the maximum sustained output current per fuse must not exceed 175 mA.

Engineering Advantages

Compact Footprint Optimization

Measuring just 170 mm in length, this module optimizes internal cabinet space compared to traditional terminal blocks combined with external fuse holders, providing high-density I/O allocation.

Reduced Total Cost of Ownership

By achieving Class I, Division 2 approval directly through internal current-limiting design, the assembly removes the requirement for expensive intrinsically safe galvanic isolators and dedicated grounding systems.

Global Safety Certifications

The module holds full industrial compliance stamps including CE, TÜV, UL, CSA, and FM, meeting the rigorous standards necessary for deployment in global refining, petrochemical, and chemical complexes.

Technical FAQs

Q1: Why is the maximum output current per fuse limited to 175 mA when the fuse itself is rated for 250 mA?
A1: The 175 mA limit enforces a safe engineering safety margin. This constraint prevents continuous operation near the thermal trip point of the fuse, preventing nuisance blowing caused by minor ambient temperature fluctuations or temporary current ripples.

Q2: What happens to the remaining 7 channels if one channel develops a short circuit to ground?
A2: If a short circuit draws current exceeding the fuse threshold on a single channel, the 250 mA common fuse for that specific group of 8 will open. This protects the system backplane but drops power to all 8 channels within that isolated group. The opposite group of 8 will continue running normally.

Q3: Can this module be used with non-certified standard digital input devices in hazardous areas?
A3: Yes, provided that the overall field circuit matches the non-incendive loop parameters (maximum loop resistance, inductance, and capacitance) defined for Gas Groups A-D. The current-limiting features of the FTA ensure that field wiring faults cannot generate a spark with sufficient thermal energy to ignite the atmosphere.

🏷️ Tags: Input Module
  • Oren

Skalar (V/f)

Vektor

Dikuasakan oleh AC

  • Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
  • Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
  • Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
  • Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
  • Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.

Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.

Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.

Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

Lihat Butiran Produk

PASTIKAN PRESTASI MESIN YANG BOLEH DIPERCAYAI

Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.