Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:IS200EPCTG1A
GE IS200EPCTG1A Simplex Exciter PT CT Terminal Module
Manufacturer: General Electric
Product No.: IS200EPCTG1A
Product Type: Terminal Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
Product Overview
The General Electric IS200EPCTG1A (functional acronym EPCT) is an Exciter PT/CT Input/Output Terminal Board developed for the GE EX2100 Series Excitation Control System. Designed for process-critical power generation environments, this module receives, conditions, scales, and isolates feedback signals from potential transformers (PTs) and current transformers (CTs) directly monitoring two three-phase generator lines.
Operating on a 28 V DC power supply, the IS200EPCTG1A features integrated isolation transformers (T1 through T6) that convert high-level generator feedback signals into low-voltage signals routed via J305, J308, and J315 connectors to the main controller boards (such as EMIO in M1, M2, or C controllers). Weighing 0.45 kg (0.99 lbs) with compact dimensions of 23.8 cm x 8.6 cm, the board operates across an extended industrial temperature range of -30°C to +65°C.
Core Technical Advantages
- Comprehensive Signal Isolation: Six internal isolation transformers (T1–T6) scale and isolate 115 V rms PT inputs and 1 A/5 A CT current signals for safe system feedback.
- Simplex & Triple Redundant Support: Fully scalable for Simplex systems or redundant control architectures using up to three EPCT boards in parallel.
- Flexible Analog Input Configuration: Features jumper JP1 selection to accept either 0–10 V DC or 4–20 mA field analog instrumentation signals.
- Enhanced Terminal Safety: Features non-removable TB2/TB3 terminal blocks to prevent hazardous CT open-circuit conditions during operational service.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | General Electric (GE) |
| Part / Catalog Number | IS200EPCTG1A |
| Functional Acronym | EPCT (Exciter PT/CT Terminal Board) |
| System Compatibility | GE EX2100 Excitation Control System |
| PT Input Rating | 115 V rms @ 50/60 Hz (Two 3-phase generator PT inputs) |
| PT Step-Down Voltage Output | 1.533 V rms (from 115 V rms 3-wire open delta input) |
| CT Input Rating | 1 A or 5 A nominal inputs from two generators |
| PT/CT Input Burden | Less than 1 VA |
| Auxiliary Analog Input | 1 Channel: 0 to 10 V DC or 4 to 20 mA (Jumper JP1 selectable) |
| Power Supply Voltage | 28 V DC |
| Terminal Blocks & Wiring | 3 Blocks (TB1 removable; TB2/TB3 fixed); supports up to #10 AWG |
| Board Dimensions | 23.8 cm High x 8.6 cm Wide (9.37 in x 3.38 in) |
| Net Board Weight | 0.45 kg (0.99 lbs) |
| Operating Temperature | -30°C to +65°C (-22°F to +149°F) |
Installation & Gap Calibration Guide
- Field Wiring Connection: Wire CT and PT secondary signals to terminal block TB1 using up to #10 AWG cable (maximum run length 1,000 feet / 300 meters).
- Jumper Configuration: Set jumper JP1 to configure the auxiliary analog input for either 0–10 V DC voltage or 4–20 mA current mode prior to powering up.
- CT Safety Notice: Ensure terminal blocks TB2 and TB3 remain permanently attached to prevent dangerous open-circuit voltage spikes across live CT secondaries.
Technical FAQs
Q1: What is the main function of the GE IS200EPCTG1A terminal board?
A1: It conditions, isolates, and scales generator PT and CT feedback signals for EX2100 exciters. (94 chars)
Q2: Why are terminal blocks TB2 and TB3 non-removable on the IS200EPCTG1A?
A2: They are fixed to protect personnel and equipment from open-circuit CT high-voltage hazards. (95 chars)
Q3: How are secondary signals routed to EX2100 system controllers?
A3: Isolated secondary signals are cabled via J305, J308, and J315 connectors to the EMIO board. (93 chars)
Spesifikasi Tambahan
- Hijau
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
How Does S7-400H Redundant PLC Work in DCS Projects?
Siemens SIMATIC S7-400 PLC remains a proven platform for large-scale industrial automation, combining redundant ...
-
How Does ABB AC500 PLC Support DCS Integration?
The ABB AC500 modular PLC delivers scalable hardware, fast CPU cycles, and native DCS communication for modern indust...
-
Can Legacy GE 90-70 PLCs Integrate with Modern DCS Systems?
GE Series 90-70 PLC modules remain critical for aging industrial control systems, and redundant hardware configu...
-
What Makes the Bently Nevada 177230 Ideal for Casing Monitoring?
The Bently Nevada 177230 seismic transmitter delivers reliable casing vibration monitoring for auxiliary rotating mac...
-
Can PLC and DCS Replace Dedicated TSI Protection?
This article examines why critical rotating machinery requires independent safety barriers separate from standard PLC...
-
Can Bently Nevada TSI Prevent Turbine Trips in Automation?
This technical article examines why standard PLC and DCS process monitoring fails to detect early-stage rotating mach...