Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:149369-01
Bently Nevada 3500/25 149369-01 Enhanced Keyphasor Module
Manufacturer: Bently Nevada
Product No.: 149369-01
Product Type: Enhanced Keyphasor Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 460g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
Bently Nevada 3500/25 149369-01 Enhanced Keyphasor Module
Bently Nevada 3500/25 149369-01 | Enhanced Keyphasor Module for 3500 Machinery Protection System. Half-height, two-channel module converts proximity probe or magnetic pickup signals into digital Keyphasor outputs. Provides precise timing for shaft speed, phase, and vector measurements. Direct plug-in replacement for 125792-01.
Key Features
2-channel half-height module. Input range 1 to 1,200,000 cpm (0.017 to 20 kHz). Output range 1 to 99,999 cpm. Auto or manual threshold triggering. Buffered Keyphasor outputs at front and rear. -24 Vdc transducer power supply. 3.2W typical power consumption. Main module weight 0.34 kg (0.76 lbs). Supports up to four Keyphasor signals standard, eight in paired configuration. Field-upgradeable firmware.
Technical Specifications
| Manufacturer | Bently Nevada |
| Part Number | 149369-01 (3500/25) |
| Product Type | Enhanced Keyphasor Module |
| Channels | 2 (half-height) |
| Input Signal Range | +0.8V to -21.0V (Non-isolated) |
| Input Frequency Range | 1 to 1,200,000 cpm (0.017 to 20 kHz) |
| Output Frequency Range | 1 to 99,999 cpm (0.017 to 1667 Hz) |
| Accuracy (Non-processed) | ±1 cpm (0.017-100Hz), ±8 cpm (101-500Hz), ±1% (501-20kHz) |
| Accuracy (Processed) | ±1 cpm (0.017-60Hz), ±8 cpm (61-150Hz), ±1% (151-20kHz) |
| Input Impedance | 21.8 kΩ minimum |
| Auto Threshold | 2V p-p min, 120 rpm (2Hz) min |
| Manual Threshold | 0 to -20Vdc, 500mV p-p min |
| Hysteresis | User-selectable 0.2 to 2.5V |
| Transducer Power Supply | -24 Vdc, 40 mA max per channel |
| Power Consumption | 3.2 W typical |
| Main Module Dimensions | 119.9 x 24.4 x 256.5 mm (4.72 x 0.96 x 10.10 in) |
| Main Module Weight | 0.34 kg (0.76 lbs) |
| I/O Module Dimensions | 241.3 x 24.4 x 103.1 mm (9.50 x 0.96 x 4.06 in) |
| I/O Module Weight | 0.46 kg (1.01 lbs) |
| Rack Space (Main) | 1 half-height front slot |
| Rack Space (I/O) | 1 full-height rear slot |
| Operating Temperature | -30°C to +65°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 95%, non-condensing |
| Origin | Made in U.S.A. |
Ordering Code Breakdown
3500/25-AA-BB-CC
A: Number of Channels – 01 = Single half-height 2-channel card; 02 = Two half-height 2-channel cards (4 channels).
B: I/O Module Type – 01 = Internal Terminations; 02 = External Terminations; 03 = Internal Barrier I/O; 04 = Isolated Internal (Magnetic Pickups); 05 = Isolated External (Magnetic Pickups).
C: Agency Approval – 00 = Not required; 01 = cNRTLus (Class I Div 2); 02 = ATEX/IECEx/CSA (Class I Zone 2).
Installation Notes
Install in half-height front slot using mounting adapter. I/O module occupies corresponding full-height rear slot. Configure trigger threshold (auto or manual) and hysteresis per application. For magnetic pickups, use Isolated I/O modules (B:04 or B:05). For hazardous area installation, follow appropriate control drawings (149243/149244 or 138547).
Engineering Advantages
Supports up to eight Keyphasor signals in paired configuration for complex machinery monitoring. Expanded frequency range handles multi-event-per-turn inputs up to 20 kHz. Auto and manual threshold options accommodate various transducer types. Direct replacement for legacy 125792-01 modules. Buffered outputs at front and rear simplify external diagnostics. Field-upgradeable firmware protects investment.
FAQs
Q1: What is the maximum input frequency?
A1: 20 kHz (1,200,000 cpm), supporting multiple events per revolution.
Q2: What is the difference between Isolated and Non-isolated I/O modules?
A2: Isolated modules (B:04/05) are designed for magnetic pickups and provide isolation from other systems. Non-isolated modules (B:01/02) are for standard proximity probe applications.
Q3: Can this module replace older Keyphasor modules?
A3: Yes, the 149369-01 Enhanced Keyphasor Module is a direct plug-in replacement for Keyphasor Module 125792-01.
Spesifikasi Tambahan
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...