  • Manufacturer: Bently Nevada

  • Product No.: 330103-09-13-10-02-00

  • Product Type: Proximity Probe

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 323g

  • Shipping port: Xiamen

  • Warranty: 12 months

Polisi Pemulangan 30 Hari · Jaminan 12 Bulan
  • Penghantaran Pantas
  • Sokongan 24/7
  • Jaminan Kualiti

Penerangan

Bently Nevada 330103-09-13-10-02-00 Proximity Probe

The 330103-09-13-10-02-00 (also cataloged as the 330103 3300 XL 8 mm Proximity Probe, Metric) provides radial vibration and axial position measurement in 3300 XL machinery monitoring systems. It has a PPS probe tip, an AISI 303/304 stainless steel case, an M10x1 thread, and a Miniature coaxial ClickLoc connector with 1.0 m cable. Probe cable weight is 323 g/m.

Hardware Specifications

Parameter Specification
Model 330103-09-13-10-02-00
Brand Bently Nevada
Product Type 3300 XL 8 mm Proximity Probe, Metric
Unthreaded Length 90 mm
Overall Case Length 130 mm
Total Length 1.0 m (3.3 ft)
Connector Miniature coaxial ClickLoc, standard cable
Probe Tip Material Polyphenylene sulfide (PPS)
Case Material AISI 303 or 304 stainless steel
Case Thread M10x1, max. thread engagement 15 mm
Nominal Probe DC Resistance 7.59 +/- 0.50 ohms at 1.0 m
Linear Range 0.25 to 2.3 mm (10 to 90 mils), approx. -1 to -17 Vdc
Recommended Gap Setting -9 Vdc [approx. 1.27 mm (50 mils)]
Operating Temp (Standard Probe) -52 deg C to +177 deg C
Field Wiring 0.2 to 1.5 mm2 (16 to 24 AWG), 3 conductor shielded triad, max. 305 m
Probe Weight 323 g/m (11.4 oz/m)

Gap Voltage and Signal Characteristics

The 330103 probe operates over a 2 mm (80 mils) linear range beginning at approximately 0.25 mm (10 mils) from the target and extending to 2.3 mm (90 mils), corresponding to approximately -1 to -17 Vdc. The recommended gap setting for radial vibration measurement is -9 Vdc, approximately 1.27 mm (50 mils). Nominal DC resistance from center conductor to outer conductor is 7.59 +/- 0.50 ohms for the 1.0 m probe length. The probe seals differential pressure between tip and case with a Viton O-ring; probes are not pressure tested prior to shipment. Average Scale Factor changes less than 3 % when tested in 93 % humidity per IEC 68-2-3 for up to 56 days. Field wiring uses 3 conductor shielded triad cable, tinned, from 0.2 to 1.5 mm2 (16 to 24 AWG), with a maximum length of 305 m (1000 ft) between the Proximitor Sensor and the monitor; signal roll-off at high frequencies occurs with longer field wiring. Standard probe temperature range is -52 deg C to +177 deg C. Exposure below -34 deg C may cause premature failure of the pressure seal. With intrinsically safe zener barriers per drawing 141092 or galvanic isolators, the probe meets Class I, Zone 0 AEx/Ex ia IIC T5...T1 Ga and Class I, Groups A-D, Class II, Groups E-G, Class III. With a nonincendive circuit per drawing 140979, it meets Class I, Zone 2 AEx/Ex nA IIC T5...T1 Gc, Class I Division 2 Groups A-D, and Class I Zone 2 AEx/Ex ec IIC T5...T1 Gc.

Field Installation Guidelines

Mount the probe in an M10x1 threaded hole with a maximum thread engagement of 15 mm. Confirm the unthreaded length of 90 mm and overall case length of 130 mm clear the machine housing and bracket. Set the radial vibration gap to -9 Vdc (approximately 1.27 mm or 50 mils) using a calibrated voltmeter before locking the probe. Route the 1.0 m ClickLoc cable and field extension through 3 conductor shielded triad cable, terminated with tinned conductors, with a total length not exceeding 305 m to the Proximitor Sensor. Ground the shield at the monitor end only. For hazardous area installation, verify the barrier or isolator matches drawing 141092 (ia) or drawing 140979 (nA) and confirm the area classification against the certification marking. Do not expose the probe to temperatures below -34 deg C to protect the pressure seal.

Frequently Asked Questions

Q: What is the recommended gap setting for radial vibration on the 330103-09-13-10-02-00?
A: -9 Vdc, approximately 1.27 mm (50 mils).

Q: What is the nominal probe DC resistance at 1.0 m?
A: 7.59 +/- 0.50 ohms from center conductor to outer conductor.

Q: What is the maximum field wiring length between the Proximitor Sensor and the monitor?
A: 305 m (1000 ft) using 3 conductor shielded triad cable.

Skalar (V/f)

Vektor

Dikuasakan oleh AC

  • Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
  • Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
  • Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
  • Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
  • Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.

Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.

Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.

Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

Lihat Butiran Produk

PASTIKAN PRESTASI MESIN YANG BOLEH DIPERCAYAI

Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.