Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:1756-IRT8I
Allen-Bradley 1756-IRT8I ControlLogix Temperature Input Module
Manufacturer: Allen-Bradley
Product No.: 1756-IRT8I
Product Type: Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
Product Overview
The Allen-Bradley 1756-IRT8I is a high-density, channel-isolated temperature input module designed for the flagship ControlLogix PLC platform. Engineered by Rockwell Automation, this advanced hardware supports up to 8 isolated input channels, allowing direct connection to Resistance Temperature Detectors (RTDs), Thermocouples, and low-voltage millivolt (mV) linear signals. By implementing strict channel-to-channel electrical isolation, the module eliminates ground loops and systemic electrical noise, making it highly reliable for harsh process manufacturing plants.
Weighing a rigid and substantiative 0.34 kg (approx. 0.75 lbs) net, the robust build profile of this module reflects its industrial-grade internal shielding and isolation components. Featuring a premium 24-bit analog-to-digital resolution (0.01 µV per count) and a pinpoint accuracy rating of ±0.3°C, the 1756-IRT8I delivers exceptional measurement depth. Its rapid 1ms scan time allows for immediate loop updates, which makes it ideal for highly sensitive thermal environments like pharmaceutical batch processing, complex chemical reactors, and industrial furnace control chambers where minor temperature fluctuations impact product safety and quality boundaries.
Technical Specifications
| Parameter / Field | Official System Specification |
|---|---|
| Module Classification | ControlLogix Temperature Sensing Input (RTD / TC / mV) |
| Channel Architecture | 8 independent, channel-to-channel isolated points |
| A/D Converter Resolution | 24-bit resolution (0.01μV/count scaling) |
| Instrument Accuracy | ±0.3°C with integrated CJC compensation |
| Module Scan Time | 1 millisecond (ms) |
| RTD Signal Ohm Ranges | 1–500 Ω up to 8–4000 Ω bounds |
| Thermocouple Signal Range | -100 to +100 millivolts (mV) |
| Backplane Current Draw | 200 mA @ 5.1V DC | 150 mA @ 24V DC |
| Normal Mode Rejection | 75 dB noise immunity |
| Net Module Weight | 0.34 kg (0.75 lbs) |
| Hardware Compatibility | Fits standard 1756 ControlLogix chassis racks |
Advanced Engineering Capabilities
Cold Junction Compensation (CJC)
To deliver precise thermocouple metrics, the 1756-IRT8I requires specific terminal housing blocks embedded with **Dual CJC sensors**. These dedicated sensors monitor localized temperature fluctuations at the physical connection blocks, allowing the hardware logic to continuously cross-reference thermal differentials and hold the system accuracy stable at ±0.3°C.
Automated Calibration & Fault Detection
The module eliminates the need for manual, scheduled tool calibrations by initiating an autonomous **auto-calibration routine** on every power cycle. Furthermore, built-in **wire break detection** active diagnostics sample line resistance profiles continuously. If a field sensor burns out or suffers a snapped lead wire, the hardware flags a channel fault tag within 2 to 5 seconds, prompting operators before control values drift dangerously.
Broad Multi-Sensor Compatibility
The 1756-IRT8I simplifies inventory footprint management by supporting an array of industry sensors out of a single slot:
- Supported RTD Elements: Platinum (100 Ω, 200 Ω, 500 Ω, 1000 Ω), Nickel (100 Ω, 120 Ω, 200 Ω, 500 Ω), and Copper (10 Ω).
- Supported Thermocouple Types: Specialized and high-temp classes including Types B, C, D, E, J, K, N, R, S, T, and TXK/XK.
Installation Requirements
Please note that the 1756-IRT8I utilizes a unique high-density 36-pin Removable Terminal Block (RTB) connector scheme. It is completely incompatible with standard 20-pin RTB units used by lower-density analog modules. Due to the 36-pin block profile and the 0.34 kg internal component mass, ensure the RTB side screws are firmly anchored to prevent mechanical sagging. Installers must order the 1756-TBCH (extended depth screw-clamp block) or the 1756-TBS6H (extended depth spring-clamp block) to establish safe and proper field terminations.
Technical FAQs
Q1: What is the benefit of the 24-bit conversion resolution over typical 16-bit analog input modules?
A1: A 24-bit resolution provides up to 0.01 µV per binary count, enabling the module to read subtle thermal shifts that 16-bit systems ignore. This grain-level tracking results in tight loop stability, allowing the PID loops within the ControlLogix processor to react to fractional variations before process trends deviate.
Q2: Why does the module draw power across both the 5.1V and 24V backplane current buses?
A2: The module splits its power duties to isolate signal paths cleanly. The 200 mA current draw on the 5.1V rail powers the internal microprocessors, A/D converters, and digital backplane communication links. The 150 mA current draw on the 24V rail runs the analog input conditioning blocks and maintains the high-potential electrical isolation barrier between channels.
Q3: Can I mix RTDs and Thermocouples on the same 1756-IRT8I module simultaneously?
A3: Yes. Because every single channel is completely isolated and possesses independent configuration parameters, you can customize each point individually in Studio 5000 Logix Designer. Channel 0 can track a Type K thermocouple while Channel 1 is configured to process a Pt100 RTD without any cross-talk or impedance issues.
Spesifikasi Tambahan
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...
-
How to streamline industrial automation spare parts import clearance?
This guide delivers a data-driven framework for sourcing and clearing industrial automation spare parts, covering PLC...
-
How Fast Must DCS Switchover Be to Prevent Costly Process Upsets?
This article presents quantified DCS redundancy strategies using real 2024–2025 plant data. It details sub-100ms swit...