Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:YXI115B
ABB YXI115B YT204001-AL Speed Input Board 24V DC
Manufacturer: ABB
Product No.: YXI115B
Product Type: Speed Input Board
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 800g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
Product Overview
The YXI115B (YT204001-AL) is a precision speed input board manufactured by ABB for industrial automation and turbine monitoring systems. Engineered to process pulse and analog speed signals, this compact unit measures 22 cm x 17 cm x 3 cm and weighs 1.76 lbs (0.8 kg). Designed for standard DIN rail mounting in IP20-rated enclosures, it integrates Modbus RTU communication to deliver reliable speed feedback in demanding industrial environments.
Core Technical Advantages
- Dual-Signal Processing: Seamlessly acquires and processes both pulse trains and analog speed inputs from machinery sensors.
- Modbus RTU Connectivity: Built-in industrial communication interface ensures smooth data integration with PLCs and control systems.
- Wide Thermal Tolerance: Operates reliably across an extended ambient temperature range from -20 °C to +70 °C.
- Robust DIN Rail Design: Compact 22x17x3 cm frame securely snaps onto standard control cabinet rails for space-saving installations.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer & Model | ABB / YXI115B (YT204001-AL) |
| Product Type | Speed Input Board / Monitoring Module |
| Input Voltage & Current | 24 V DC nominal; 0.1 A input current |
| Speed Input Signal Type | Pulses / Analog inputs |
| Communication Interface | Modbus RTU serial protocol |
| Physical Dimensions & Mass | 22 cm x 17 cm x 3 cm; Net Weight: 1.76 lbs (0.8 kg) |
| Operating Temperature Range | -20 °C to +70 °C (-4 °F to +158 °F) |
| Mounting & Protection | DIN Rail Mount; IP20 Enclosure Protection |
| Certifications | CE Marked, UL Listed |
Industrial Solutions
- Turbine Speed Monitoring: Tracks rotational velocity and frequency pulses on industrial power generation turbines.
- Heavy-Duty Motor Drives: Interfaces speed feedback loops in large-scale manufacturing and processing plants.
- Conveyor & Rolling Mills: Provides accurate velocity tracking for synchronized multi-motor drive systems.
- Distributed Control Systems: Communicates real-time speed parameters over Modbus RTU networks to main automation controllers.
Wiring & Installation
Power Supply Preparation
Ensure cabinet power is turned off. Connect a stable 24 V DC power source to the designated supply terminals, verifying proper polarity before energizing.
DIN Rail Mounting
Snap the 0.8 kg board securely onto a standard industrial DIN rail inside an IP20 or better protective control enclosure, allowing adequate clearance for heat dissipation.
Signal & Communication Wiring
Connect pulse or analog speed sensors to the input channels. Wire the Modbus RTU communication interface using shielded twisted-pair cable to prevent electrical noise interference.
System Verification
Power on the unit and check status LEDs to confirm normal operation, proper 24V supply voltage, and active Modbus communication polling.
Engineering Advantages
- High Precision Acquisition: Accurate conversion of high-frequency pulses and analog inputs for critical speed regulation.
- Standardized Industrial Protocol: Modbus RTU integration allows straightforward connection to third-party PLCs and HMIs.
- Rugged Environmental Build: Withstands harsh cabinet environments ranging from -20 °C up to +70 °C.
Technical FAQs
Q1: What power supply does the YXI115B board require?
A1: Operates on a 24 V DC supply drawing approximately 0.1 A of input current.
Q2: What communication protocol does this speed input board use?
A2: It utilizes the Modbus RTU protocol for serial communication and data exchange.
Q3: What are the physical dimensions and weight of the module?
A3: Measures 22 x 17 x 3 cm and weighs 1.76 lbs (0.8 kg).
Spesifikasi Tambahan
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
How Do You Tune a 3500/92 Gateway for Stable Modbus TCP Polling?
This article explains why Bently Nevada 3500/92 Modbus TCP gateways fail in industrial control systems and how automa...
-
How Can You Prevent GE PLC Backup Failures?
This article explains why GE PLC backup failures occur in RX3i and VersaMax environments. It presents measured root c...
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...