Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:CI920AN
ABB 3BDH000692R1 CI920AN Advant 800xA Communication Interface
Manufacturer: ABB
Product No.: CI920AN
Product Type: I/O Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 130g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
Core Technical Advantages
Seamless HART Field Device Pass-Through
The CI920AN natively supports HART protocol bridging over the PROFIBUS DP network configuration. This allows maintenance engineering teams to perform asset management operations, calibrate remote transmitters, change process parameters, and view advanced health metrics directly from the central control room without running dedicated secondary instrumentation wires.
Advanced System and Network Redundancy
To maximize uptime in critical continuous-process environments, the CI920AN supports full master/slave line redundancy. If a primary master module failure or a network cable break is detected, the redundant standby configuration takes over the communication bus instantaneously, ensuring zero data drops or unexpected automated plant shutdowns.
Rugged S900 Modular Architecture
Part of the rugged S900 system platform, the CI920AN features an extremely small physical footprint (20mm thickness), optimizing DIN rail real estate inside control marshaling panels. Its energy-efficient internal circuitry generates minimal thermal load, contributing to its broad ambient operating spectrum and long-term lifespan.
Technical Specifications
| Parameter Code | Specification Details |
|---|---|
| Brand / Manufacturer | ABB Automation |
| Catalog Part Number | 3BDH000692R1 |
| Model Identification | CI920AN (Non-IS Version) |
| Signal / Module Type | PROFIBUS DP Remote I/O Communication Interface |
| HART Protocol Compatibility | Yes (Supports cyclic and acyclic HART parameter routing) |
| Redundancy Support | Yes (Supports dual redundant network line topologies) |
| Mechanical Classification | S900 Sub-rack Mountable Module |
| Dimensions (W x D x H) | 20 x 104 x 104 mm (0.79 x 4.09 x 4.09 inches) |
| Operating Temperature Range | -20°C to 60°C (-4°F to 140°F) |
| Environmental Compliance | CE Marked, RoHS Directive 2011/65/EU, WEEE Small Equipment |
Installation and Maintenance
S900 Slot Mounting and Hot-Swap Guidelines
The CI920AN is engineered to snap directly into the designated communication slots on an S900 terminal unit or backplane chassis. To install, align the rear connector pin layout with the sub-rack guide tracking channels and press firmly until the locking tabs snap into place. The module supports live-insertion/hot-swapping configurations, allowing maintenance teams to change components without interrupting power to the remaining active I/O rack segments.
Redundant Bus Line Termination and Configuration
When implementing redundant topologies, install dual CI920AN modules into the corresponding primary and secondary sub-rack slots. Ensure the interconnecting PROFIBUS DP cables are terminated using high-quality network plugs with integrated terminating resistors active on both ends of the segment to avoid signal reflections and data communication corruption.
Climatic Control and Environmental Preservation
The module is certified to perform across a broad temperature scale (-20°C to 60°C) and withstand non-condensing relative humidity levels up to 93% (±3% at 40°C). For outdoor marshaling applications or environments high in ambient particulate count, house the S900 system sub-rack assembly within a sealed, climate-controlled cabinet matching IP65 or NEMA 4 standards.
Engineering Advantages
Direct System 800xA Optimization
By routing field information through standard PROFIBUS DP layers, the CI920AN offers smooth integration with ABB’s core asset optimization software utilities. This integration maps process inputs, diagnostic registers, and status alerts directly into the operator workstation environment without requiring complex ladder logic rewriting.
Reduced Engineering and Wiring Overhead
Combining many analog and digital I/O clusters onto a single serial communication line reduces the total volume of field cables running back to the main control station. This distributed I/O framework simplifies project engineering, lowers installation costs, and reduces the time required for system commissioning.
Comprehensive Compliance Standards
Complying with strict European CE mandates, RoHS Directive 2011/65/EU, and falling into the WEEE Small Equipment category (external dimensions ≤ 50cm), this module meets environmental and electronic safety standards required for global infrastructure, power generation, and manufacturing applications.
Technical FAQs
Q1: Can the CI920AN 3BDH000692R1 be installed directly in ATEX Zone 1 hazardous explosive zones?
A1: No. While the S900 family contains modules specifically engineered for intrinsically safe field areas, the CI920AN (Model Code ending with 'N') is classified as a non-intrinsically safe interface module. It should be mounted inside a safe area or within a flame-proof / purged enclosure when used in hazardous industrial settings.
Q2: How does the CI920AN handle a sudden failure of the primary PROFIBUS line?
A2: When deployed in a redundant configuration with a secondary backup module, both units monitor network status in real time. If the active communication channel fails or experiences a broken cable, the internal firmware switches to the redundant link within milliseconds, ensuring uninterrupted control loop data tracking.
Q3: Does this module require specialized software toolsets for initial node address assignment?
A3: Initial node station addresses can typically be configured using standard hardware configuration switches located on the module/backplane housing, or established via PROFIBUS network master configuration software utilities during system integration.
Spesifikasi Tambahan
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
How Does Honeywell SCADA Unify Multi-Site Manufacturing?
Honeywell SCADA enables manufacturers to unify monitoring across three to eight distributed plants while preserv...
-
How Do Eddy Current Probes Protect Rotating Machinery?
Bently Nevada eddy current proximity sensors deliver precise shaft displacement data for turbine and compressor prote...
-
How Can You Migrate ABB PLCs Without Stopping Production?
Aging ABB PLC platforms create rising reliability and spare-part risks for process plants. This article explains wher...
-
How Does Honeywell DCS Modernization Cut Refinery Downtime?
Honeywell DCS modernization helps refineries replace aging control hardware without full shutdowns. It tightens proce...
-
Why Do Hybrid DCS-PLC Systems Cause False Trips?
This article explains how to align Emerson DCS anti-surge control with ABB PLC compressor protection in hybrid ind...
-
How Can Brownfield Upgrades Modernize GE Fanuc DCS Visualization?
Aging GE Fanuc DCS visualization stacks create spare part delays, alarm chaos and unplanned downtime. This article ex...