Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:DI581-S
ABB 1SAP284000R0001 DI581-S AC500-S Safety Discrete Input Module
Manufacturer: ABB
Product No.: DI581-S
Product Type: Digital Input Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 135g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
Product Overview
The ABB DI581-S (1SAP284000R0001) is a high-integrity 16-channel safety digital input module designed for the AC500-S Safety PLC system. Engineered for functional safety applications up to SIL 3 (IEC 62061) and PL e (ISO 13849-1), it provides reliable 24 V DC signal acquisition from field safety devices such as emergency stop buttons, light curtains, and safety switches. Operating with a low logic current draw of 0.18 A at 24 V DC, the DI581-S features comprehensive internal diagnostics, reverse polarity protection, and robust environmental resilience for demanding industrial control systems. Weighing approximately 0.135 kg (0.30 lbs), this compact module mounts onto standard AC500 terminal units (TU582-S).
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Model | DI581-S |
| Order Code / Part Number | 1SAP284000R0001 |
| PLC Family | ABB AC500-S Safety PLC System |
| Number of Channels | 16 Safety Digital Inputs (24 V DC) |
| Safety Integrity Level | SIL 3 (IEC 62061 / IEC 61508), PL e (ISO 13849-1) |
| Rated Supply Voltage | 24 V DC (-15%, +20%, max 5% ripple) |
| Signal Voltage Levels | Signal 0: -3 to +5 V | Signal 1: +15 to +30 V |
| Electronics Current Draw | 0.18 A @ 24 V DC |
| Maximum Cable Length | 600 m (unshielded field wiring) |
| Protection & Fuse Rating | Reverse Voltage Protection | 10 A Fast-Blow (UP) |
| Operating Humidity & Pressure | Max 95% RH (non-condensing) | > 800 hPa (< 2000m) |
| Storage & Transport Temp. | -40°C to +85°C (-40°F to +185°F) |
| Net Weight | 0.135 kg (0.30 lbs) |
Key Design & Hardware Features
- SIL 3 / PL e Functional Safety Certification: Purpose-built for high-integrity safety loops in automated systems, machine safety, and hazardous process environments.
- Long-Distance Unshielded Cabling: Supports up to 600-meter unshielded cable runs, reducing installation costs and enabling long-distance field sensor connections.
- Power Interruption Immunity: Tolerates DC power supply interruptions up to 10 ms without dropping safety state, maintaining high operational availability.
- Comprehensive Electrical Protection: Integrated reverse voltage protection and fast-blow 10 A external fuse rating safeguard logic electronics against field wiring faults.
Installation Guidelines
1. Terminal Unit Mounting: Snap the DI581-S safety module onto its corresponding AC500-S safety terminal unit (e.g., TU582-S) until the locking mechanism fully engages.
2. Grounding & Shielding: Although unshielded cables up to 600m are supported, ensure the 24 V DC field supply common (FE) is connected to functional earth to maximize EMC resistance in high-noise environments.
3. Power Supply Fuse Protection: Install a 10 A fast-blow fuse on the UP supply line to protect the module internal power routing from external short-circuit events.
Frequently Asked Questions (FAQs)
Q1: Can the ABB DI581-S module be used in standard non-safety AC500 CPUs?
A1: The DI581-S is specifically designed for the AC500-S Safety PLC platform and must be managed by an AC500 safety CPU (such as the SM560-S) to execute SIL 3 / PL e safety logic.
Q2: What happens during short DC power supply dips?
A2: The module incorporates power-ride-through capability that withstands DC supply interruptions under 10 ms, preventing false safety trips during transient power fluctuations.
Q3: What terminal unit is compatible with the DI581-S 1SAP284000R0001 module?
A3: The DI581-S connects to the TU582-S safety terminal unit, which provides dedicated terminal connections for the 16 safety digital inputs and test outputs.
Spesifikasi Tambahan
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
Can GE Fanuc PLC + Emerson DCS Cut Your Plant Upgrade Costs?
This article examines a data-proven retrofit strategy combining GE Fanuc PLC and Emerson DeltaV DCS for legacy indust...
-
Why Bently Nevada Bridges Process Control and Machine Health?
Unobserved mechanical vibration remains a critical blind spot in modern factory automation, causing up to 8% annual r...
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
