Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:8440-1935
8440-1935 Woodward easYgen-3500 Sheet Metal Chassis CPU
Manufacturer: Woodward
Product No.: 8440-1935
Product Type: Operator Interface
Product Origin: USA
Payment:T/T, Western Union
Weight: 1850g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
Product Overview
The 8440-1935 (alternatively designated as the easYgen-3500-1-P1) is an advanced genset controller from Woodward's easYgen-3000 series. Housed in a durable sheet metal chassis designed for cabinet installation, this unit features integrated generator group breaker control. Weighing approximately 4.08 lbs (1,850 g) with front panel dimensions of 282W x 216H x 96D mm, it delivers high-precision power management with 16-bit resolution and an Accuracy Class of 0.5.
Core Technical Advantages
- High-Precision Measurement: Engineered to Accuracy Class 0.5 with 16-bit resolution and a wide setting range from 1 to 32,000 A.
- Integrated Breaker Control: Equipped with built-in generator group breaker control for seamless synchronization and switching.
- Isolated Discrete Inputs: Features robust isolated discrete input channels to protect internal circuitry from field electrical noise.
- Rugged Sheet Metal Build: Sturdy 1,850 g chassis built to withstand harsh industrial generator control environments.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer & Series | Woodward Inc. / easYgen-3000 Series |
| Part Number / Model | 8440-1935 (easYgen-3500-1-P1) |
| Accuracy Class & Resolution | Accuracy Class 0.5; 16-Bit Resolution |
| Current Setting Range | 1 to 32,000 A |
| Discrete Inputs | Isolated Discrete Inputs |
| Chassis & Dimensions | Sheet Metal Chassis; 282W x 216H x 96D mm |
| Net Weight | Approx. 1,850 g (4.08 lbs) |
| Power Factor Circuits | Supports Capacitive, Resistive (Unity 1.00), and Inductive Circuits |
Industrial Solutions
- Standby & Prime Power Generators: Manages automatic start/stop, synchronization, and breaker control for diesel and gas generator sets.
- Multi-Gen Paralleling Systems: Coordinates load sharing and power factor regulation across complex multi-generator installations.
- Industrial Power Management: Provides reliable monitoring and protection in industrial switchgear and utility backup panels.
Wiring & Installation
Cabinet Mounting & Chassis Grounding
Install the controller inside a protective industrial cabinet using the 282W x 216H x 96D mm cutout profile. Do not connect wires directly to the protective earth terminal on the controller body; route any necessary ground connections exclusively through the designated bottom connector.
Current Transformer Safety Precaution
Always ensure that current transformers (CTs) are properly short-circuited before disconnecting wiring from the controller. Failing to short-circuit CTs during disconnection can result in hazardous high voltages, severe personal injury, or death.
Power Factor Configuration
Configure power factor parameters based on your system load type—capacitive, purely resistive (targeting unity 1.00 where voltage and current waveforms are in step), or inductive.
Engineering Advantages
- Advanced Power Factor Management: Accurately calculates real-to-apparent power ratios across resistive, inductive, and capacitive circuit profiles.
- Robust Isolation: Isolated discrete inputs safeguard internal processing components from heavy electrical transients.
- Flexible Switchgear Integration: Built-in breaker control logic streamlines synchronization architecture in generator control panels.
Technical FAQs
Q1: What is the model designation and accuracy class of the 8440-1935?
A1: It is also known as the easYgen-3500-1-P1 and features an Accuracy Class of 0.5 with 16-bit resolution.
Q2: What safety precaution is critical when disconnecting current transformers?
A2: You must short-circuit the current transformer before disconnection to prevent severe injury or death from high voltage.
Q3: What are the physical dimensions and weight of this controller?
A3: Dimensions are 282W x 216H x 96D mm, with a net weight of approximately 1,850 g (4.08 lbs).
Spesifikasi Tambahan
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...
-
How Does Bently Nevada Balancing Stabilize Turbo Machinery?
This article explains how Bently Nevada TSI instruments enable practical field dynamic balancing for turbo machinery....
-
What Makes GE Historian Ideal for Industrial Time-Series Storage?
GE Historian delivers optimized long-term industrial time-series storage for control systems. It compresses OT data b...
-
How Do You Calibrate Honeywell Transmitters in Hazardous Areas?
This article explains how to calibrate Honeywell field instruments safely in hazardous areas, covering pre-calibratio...
-
How to Cut Bently Nevada TSI False Alarms on Compressor Skids?
This article explains how Bently Nevada TSI network layout affects compressor skid vibration monitoring reliability. ...