Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:6ES7313-1AD03-0AB0
6ES7313-1AD03-0AB0 Siemens S7-300 CPU 313 Original Stock
Manufacturer: Siemens
Product No.: 6ES7313-1AD03-0AB0
Product Type: CPU Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 530g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
SIEMENS 6ES7313-1AD03-0AB0 SIMATIC S7-300 CPU 313
The SIEMENS 6ES7313-1AD03-0AB0, also cataloged as the 6ES7313-1AD03-0AB0 CPU 313, operates as a central processing unit with integrated 24 VDC power supply executing user logic within SIMATIC S7-300 platforms at 12 kbyte working memory.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6ES7313-1AD03-0AB0 |
| Brand | Siemens |
| Product Type | CPU 313 Spare Part |
| Series | SIMATIC S7-300 |
| Rated Supply Voltage | 24 VDC |
| Permissible Range | 20.4 V to 28.8 VDC |
| Inrush Current | 8 A typ. |
| Power Loss | 8 W typ. |
| Work Memory | 12 kbyte integrated (12 KB / 4K instructions RAM) |
| Load Memory | FEPROM expandable to 4 Mbyte, integrated RAM 20 kbyte max |
| Backup | Battery (all blocks) or battery-free (72 bytes) |
| Bit Operation Time | 0.6 us typ., 1.2 us max |
| Word Operation Time | 2 us typ. |
| Fixed Point Arithmetic | 3 us typ. |
| Floating Point Arithmetic | 60 us typ. |
| Timer/Counter Operation | 15 us typ. |
| S7 Counters | 64 (35 retentive with or without battery) |
| S7 Timers | 128 (35 retentive with battery) |
| Flag Memory | 256 byte max (M 0.0 to M 71.7 retentive) |
| Digital Channels | 256 inputs, 256 outputs |
| Analog Channels | 64 inputs, 32 outputs |
| MPI Interface | 1 x MPI, max 32 nodes, 187.5 kbit/s max |
| Dimensions (W x H x D) | 80 mm x 125 mm x 130 mm |
| Weight | 530 g (approx.), memory card 16 g |
CPU Function and MPI Communication
Unit weight is approximately 530 g with dimensions of 80 mm width, 125 mm height, and 130 mm depth. The CPU 313 integrates a 24 VDC power supply and 12 kbyte working memory supporting 4K instructions. Load memory is expandable via Flash-EPROM to a maximum of 4 Mbyte, with 20 kbyte integrated RAM. Battery-backed backup retains all blocks; battery-free backup retains 72 bytes of memory bits, times, counters, and data. The integrated MPI interface supports up to 32 nodes at a maximum transmission rate of 187.5 kbit/s. Without repeaters, MPI cable length is limited to 50 m; with 2 repeaters, 1100 m; with 10 repeaters in series, 9100 m; via fiber optic cable, 23.8 km with 16 star hubs or OLMs. Per CPU, a maximum of 4 static and 4 dynamic connections are supported. Programming uses STEP 7 V5.0 or higher. Cycle time monitoring is adjustable from 1 ms to 6000 ms with a preset of 150 ms. SCL is supported as an optional programming language. User program protection via password is available.
Frequently Asked Questions
Q: What is the weight and physical size of the 6ES7313-1AD03-0AB0?
A: Approximately 530 g, with dimensions of 80 mm width, 125 mm height, and 130 mm depth. The memory card weighs approximately 16 g.
Q: What is the maximum MPI cable length supported by the CPU 313?
A: 50 m without repeaters, 1100 m with 2 repeaters, 9100 m with 10 repeaters in series, and 23.8 km via fiber optic cable with 16 star hubs or OLMs.
Q: What programming software is required for this CPU?
A: STEP 7 V5.0 or higher. SCL is supported as an optional programming language.
Field Installation Guidelines
Install the CPU in slot 2 of the S7-300 rail and secure the mounting screws. Verify 24 VDC supply polarity before energizing the backplane. Confirm STEP 7 V5.0 or higher is used for configuration. Route MPI cable within the calculated repeater limits for the required distance. Verify battery backup is installed if all blocks must be retained after power loss; otherwise only 72 bytes are retained without battery. Configure cycle time monitoring between 1 ms and 6000 ms based on the application scan time. Verify module bus connections to adjacent I/O modules after insertion.
Spesifikasi Tambahan
- Dikuasakan oleh DC
- Modular
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
Troubleshoot Allen-Bradley PLC and ABB DCS Commissioning Faults?
Joint commissioning of Allen-Bradley PLC and ABB DCS systems demands rigorous signal mapping, layered diagnostics, an...
-
What Causes Packet Loss in DeltaV and ABB Fieldbus Networks?
This article explains how to optimize communication between Emerson DeltaV DCS and ABB fieldbus control modules ...
-
How Does Allen-Bradley Redundant PLC Improve DCS Safety?
This article explains how Allen-Bradley redundant PLC deployment supports petrochemical DCS safety control. It covers...
-
Can Mixed-Vendor PLCs Unite Without Full Replacement?
ABB industrial Ethernet modules translate protocols across Allen-Bradley, Siemens, and ABB PLC platforms in brownfiel...
-
How Do You Troubleshoot GE Fanuc PSU Failures?
This guide explains how field engineers can detect, diagnose, and prevent GE Fanuc power supply failures in legacy fa...
-
How Does Bently Nevada Transducer Replacement Cut Fan Downtime?
This article explains how to replace Bently Nevada vibration transducers on centrifugal fans without disrupting plant...