Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:330905-00-13-05-01-05
330905-00-13-05-01-05 | Bently Nevada 3300 NSv Probe
Manufacturer: Bently Nevada
Product No.: 330905-00-13-05-01-05
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
Product Overview
The Bently Nevada 330905-00-13-05-01-05 is a 3300 NSv proximity probe with an M10×1 thread, 130 mm case length, and 0.5 m miniature coaxial ClickLoc cable. It measures shaft vibration and axial position on turbines, compressors, and pumps with a 1.5 mm linear range and 7.87 V/mm scale factor. Each probe weighs approximately 0.45 kg, keeping bracket loading low. The PPS probe tip and AISI 304 stainless steel case resist chemical attack in process compressor service.
Technical Configuration
Model Code Breakdown
The 330905 code defines the NSv probe family. The -00- option sets a 0 mm unthreaded length. The -13- option sets a 130 mm overall case length. The 05 option sets a 0.5 m total length. The 01 option specifies a miniature coaxial ClickLoc connector with connector protector and standard cable. The -05 agency approval option covers multiple approvals.
Core Hardware
The probe uses a polyphenylene sulfide tip and AISI 304 stainless steel case. The 75 Ω coaxial FEP cable carries the signal to the protected ClickLoc connector. A Viton O-ring seals differential pressure between the probe tip and case. The probe is mechanically and electrically interchangeable with the earlier 3300 RAM probe and extension cable.
Technical Specifications
| Parameter | Specification |
| Linear Range | 1.5 mm (60 mils), 0.25 to 1.75 mm |
| Recommended Gap | 1.0 mm (40 mils) |
| Scale Factor | 7.87 V/mm (200 mV/mil) +12.5%/-20% |
| Deviation from Best Fit | Less than ±0.06 mm (±2.3 mils) |
| Frequency Response | 0 to 10 kHz, +0/-3 dB typical |
| Probe DC Resistance | 4.0 ± 0.5 ohms at 0.5 m |
| Operating Temperature | -52°C to +177°C (-62°F to +351°F) |
| Minimum Bend Radius | 25.4 mm (1.0 in) |
| Target Size | Min 8.9 mm, recommended 13 mm |
| Thread | M10×1, 15 mm max engagement |
| Probe Case Torque | 7.5 N·m recommended, 22.6 N·m max |
| Field Wiring | 0.2 to 1.5 mm², max 305 m |
| Weight | Approx. 0.45 kg |
Installation Guide
Set the gap at 1.0 mm (40 mils) using a feeler gauge or the -1 to -13 Vdc output reading. Keep the minimum bend radius at 25.4 mm to avoid cable damage. Apply 7.5 N·m torque to the M10×1 probe case, never exceeding 22.6 N·m. Use three-conductor shielded triad cable for field wiring and keep total length under 305 meters. At roughly 0.45 kg, the probe adds minimal load to the mounting bracket. Confirm the Viton O-ring seats correctly before pressurizing the machine.
Engineering Advantages
The NSv probe delivers higher chemical resistance than the 3300 RAM probe, extending service life in process compressor environments. Its side-view characteristics outperform the 3000-series 190 probe when gapping at the same distance from the target. The probe and extension cable interchange directly with existing 3300 RAM installations, cutting upgrade downtime. The lightweight 0.45 kg body reduces bracket stress, while the PPS tip and stainless steel case hold up under -52°C to +177°C operating ranges.
Technical FAQs
Q1: How do I set the probe gap?
A1: Target 1.0 mm (40 mils), which corresponds to roughly -10 Vdc. Confirm the reading falls within the -1 to -13 Vdc linear range before locking the probe.
Q2: What does the -05 approval option add?
A2: The -05 option carries multiple agency approvals, qualifying the probe for hazardous-area installations across several certification schemes. Check the nameplate against your site zone requirements.
Q3: What does the 01 connector option include?
A3: The 01 option adds a miniature coaxial ClickLoc connector with a connector protector and standard cable. The 05 option sets the total length to 0.5 meter (20 in).
Spesifikasi Tambahan
- Perak
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...