Trasforma la tua casa con le ultime soluzioni multi-elettroniche, dall'illuminazione intelligente ai dispositivi controllati tramite voce, tutti progettati per rendere la vita più facile, sicura e connessa. Ottimizza le tue operazioni con il Sistema di Monitoraggio Bently Nevada 3500, che offre il monitoraggio in tempo reale delle vibrazioni e delle condizioni delle macchine per prevenire guasti e massimizzare il tempo di attività.
SKU:6ES7441-2AA03-0AE0
Siemens CP 441-2 6ES7441-2AA03-0AE0 Dual Channel Module
Manufacturer: Siemens
Product No.: 6ES7441-2AA03-0AE0
Product Type: Communication Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 720g
Shipping port: Xiamen
Warranty: 12 months
Condividi
- Consegna Veloce
- Assistenza 24 ore su 24, 7 giorni su 7
- Assicurazione della qualità
Descrizione
SIEMENS 6ES7441-2AA03-0AE0 SIMATIC S7-400 CP 441-2 Communication Module
The SIEMENS 6ES7441-2AA03-0AE0, also cataloged as the CP 441-2 Communication Module, operates as a dual-channel point-to-point interface with variable interface modules for 20 mA (TTY), RS 232C (V.24), and RS 422/485 connections within SIMATIC S7-400 platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6ES7441-2AA03-0AE0 |
| Brand | Siemens |
| Product Type | CP 441-2 Communication Module |
| Series | SIMATIC S7-400 |
| Weight | 720 g (approx.), interface module 100 g |
| Dimensions (W x H x D) | 25 mm x 290 mm x 210 mm |
| Current from Backplane Bus | 700 mA max at 5 VDC (without interface module) |
| Interface Modules | 20 mA (TTY), RS 422/485 (X.27), RS 232C (V.24) |
| Interface Module Consumption | 300 mA max at 5 V; 45 mA max at 24 V (TTY) |
| Number of Interfaces | 2, variable |
| Shielded Cable Length | 1000 m (TTY), 10 m (RS 232), 1200 m (RS 422/485) |
| Transmission Rate | 115.2 kbit/s max distributed on both interfaces; 19.2 kbit/s max on TTY |
| Integrated Protocols | 3964 (R), ASCII, RK512, Printer |
| Reloadable Drivers | Customer-specific drivers supported |
| Connections | 8 overall |
| Configuration Software | STEP 7 with own parameter assignment forms |
| Memory per Interface | 1 to 5 kbyte parameters; 0 to 55 kbyte message texts; 0 to 64 kbyte loadable drivers |
Dual-Channel Interface Physics and Protocol Handling
Unit weight is approximately 720 g with an interface module at approximately 100 g, dimensions of 25 mm width, 290 mm height, and 210 mm depth. The CP 441-2 provides 2 variable interfaces accepting interchangeable modules for 20 mA (TTY), RS 232C (V.24), and RS 422/485 (X.27) physics. Shielded cable lengths are limited to 1000 m for TTY, 10 m for RS 232, and 1200 m for RS 422/485. Transmission rate reaches 115.2 kbit/s distributed across both interfaces on RS 422/485 and RS 232, and 19.2 kbit/s on TTY. Integrated drivers cover 3964 (R), ASCII, RK512, and Printer, with reloadable customer-specific drivers supported. Supported printers include HP-Deskjet, HP-Laserjet, IBM-Proprinter, and user-defined models. Backplane bus current draw is 700 mA maximum at 5 VDC without interface modules; each interface module draws up to 300 mA at 5 V and 45 mA at 24 V for TTY. Parameter memory requirements on the S7-CPU memory card are 1 to 5 kbyte for parameters, 0 to 55 kbyte for message texts, and 0 to 64 kbyte for loadable drivers. The module supports 8 connections overall with S7 extended communication. Configuration uses STEP 7 with dedicated parameter assignment forms. A configuration package is included on CD.
Frequently Asked Questions
Q: What is the weight and physical size of the 6ES7441-2AA03-0AE0?
A: Approximately 720 g, with dimensions of 25 mm width, 290 mm height, and 210 mm depth. The interface module weighs approximately 100 g.
Q: How many interfaces does the CP 441-2 provide and what is the maximum transmission rate?
A: 2 variable interfaces with a maximum transmission rate of 115.2 kbit/s distributed across both interfaces.
Q: Does the CP 441-2 support RK512 and reloadable customer-specific drivers?
A: Yes. Integrated drivers include 3964 (R), ASCII, RK512, and Printer, with reloadable customer-specific drivers supported.
Field Installation Guidelines
Insert the module into the S7-400 rack and secure the mounting screws. Install the required interface modules before energizing. Route shielded cable within the limits of the installed interface physics: 1000 m for TTY, 10 m for RS 232, and 1200 m for RS 422/485. Ground the shield at one end. Verify total backplane current with all interface modules installed does not exceed the rack supply capacity. Confirm protocol, printer driver, and RK512 configuration in STEP 7 match the connected device before commissioning. Verify the S7-CPU memory card has capacity for up to 64 kbyte of loadable drivers. Install the configuration package from CD before parameter assignment.
Specifiche aggiuntive
Scalare (V/f)
Vettore
Alimentato a corrente alternata
Guida all'acquisto
- Conferma il modello esatto, il numero di parte e le specifiche prima di ordinare.
- Verifica la compatibilità con la tua macchina o i sistemi di controllo attuali.
- Contatta sale@etowonauto.com o +8617859788089 per assistenza tecnica.
- Esamina le opzioni di consegna, i tempi di attesa e i requisiti di spedizione.
- Segui le istruzioni del produttore e le migliori pratiche durante l’installazione.
Spedizione e Resi
Gli articoli disponibili in magazzino vengono solitamente spediti lo stesso giorno lavorativo. Per i prodotti non attualmente disponibili, i tempi di spedizione possono variare in base alla disponibilità. La spedizione internazionale è disponibile e i costi di spedizione sono calcolati in base alla destinazione, al peso e al corriere scelto.
Le restituzioni sono accettate entro 30 giorni dal ricevimento, a condizione che gli articoli siano inutilizzati e nelle condizioni originali. Le spese di spedizione per la restituzione sono a carico del cliente. Si prega di contattarci prima di restituire qualsiasi articolo per ricevere l'autorizzazione al reso.
Per maggiori dettagli, si prega di consultare la nostra Politica di Spedizione e Reso.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Spedizione Veloce
Ricambi originali per automazione industriale disponibili per spedizione rapida in tutto il mondo.
-
Resi Facili
Supporto per resi entro 30 giorni con garanzia di 12 mesi per una protezione post-vendita affidabile.
-
Supporto 24/7
Supporto professionale reattivo per aiutare a mantenere operazioni stabili ed efficienti.
-
Autentico e Originale
100% autentico, proveniente direttamente da produttori affidabili di automazione industriale.
Guida tecnica e all'acquisto
-
Is Compact DCS Better Than PLC for Small Plants?
This article examines the ABB AC700F Freelance DCS as a compact control solution for small batch process plants ...
-
What Makes ControlEdge UCD Ideal for Water Treatment DCS?
Honeywell ControlEdge UCD DCS delivers DCS-grade reliability in a compact, PLC-like footprint suited to mid-size muni...
-
Why Is Redundant DCS Essential for 24/7 Process Automation?
ABB Freelance AC900F redundant DCS delivers hot standby CPU switching within 5 ms, hot-swappable S700 I/O, and verifi...
-
What Makes Honeywell C200 DCS Installation Standards So Critical?
This article examines Honeywell Experion PKS C200 DCS installation standards, key technical parameters, CPU and I/O f...
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...