Trasforma la tua casa con le ultime soluzioni multi-elettroniche, dall'illuminazione intelligente ai dispositivi controllati tramite voce, tutti progettati per rendere la vita più facile, sicura e connessa. Ottimizza le tue operazioni con il Sistema di Monitoraggio Bently Nevada 3500, che offre il monitoraggio in tempo reale delle vibrazioni e delle condizioni delle macchine per prevenire guasti e massimizzare il tempo di attività.
SKU:ATV71HC11N4D
Schneider Variable Speed Drive 215A | ATV71HC11N4D
Manufacturer: Schneider
Product No.: ATV71HC11N4D
Product Type: Variable Speed Drive
Product Origin: FR
Payment:T/T, Western Union
Weight: 90000g
Shipping port: Xiamen
Warranty: 12 months
Condividi
- Consegna Veloce
- Assistenza 24 ore su 24, 7 giorni su 7
- Assicurazione della qualità
Descrizione
Schneider Electric ATV71HC11N4D Altivar 71 Variable Speed Drive
Schneider Electric ATV71HC11N4D | Altivar 71 variable speed drive for complex, high-power machines. Delivers 110 kW (150 HP) motor power with 215 A nominal output current at 380-480V three-phase supply. Integrated EMC filter and heat sink. Reinforced version without DC choke, designed for door mounting. Supports asynchronous and synchronous motors. Weight: 90 kg (198.4 lbs).
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | ATV71HC11N4D |
| Product Line | Altivar 71 |
| Product Type | Variable Speed Drive |
| Motor Power | 110 kW (150 HP), 3-phase 380-480V |
| Supply Voltage | 380-480V (-15%/+10%), 3-phase |
| Supply Voltage Limits | 323-528V |
| Supply Frequency | 50-60 Hz ±5% (47.5-63 Hz) |
| Line Current (480V) | 163 A |
| Line Current (380V) | 202 A |
| Apparent Power | 133 kVA @ 380V |
| Nominal Output Current | 215 A @ 2.5 kHz |
| Maximum Transient Current | 323 A for 60 s; 355 A for 2 s |
| Output Frequency | 0.1-500 Hz |
| Nominal Switching Frequency | 2.5 kHz (adjustable 2.5-8 kHz) |
| Prospective Line Isc | 35 kA |
| EMC Filter | Integrated |
| Heat Sink | Yes |
| Variant | Reinforced version, without DC choke |
| Mounting Type | Door Mount |
| Control Methods | Sensorless Vector, Vector, V/f, Synchronous |
| Braking to Standstill | DC injection |
| Analog Inputs | 2 (AI1 ±10V, AI2 0-20mA/0-10V) |
| Analog Output | 1 (AO1 0-20mA/0-10V) |
| Discrete Inputs | 7 (LI1-LI5 programmable 24VDC, LI6 configurable, PWR safety) |
| Discrete Outputs | 2 relay (R1 NO/NC, R2 NO) |
| Communication | Modbus (2-wire RS485), CANopen |
| Transmission Rates (Modbus) | 4800, 9600, 19200, 38.4 kbps |
| Transmission Rates (CANopen) | 20 kbps to 1 Mbps |
| Speed Accuracy (Closed-Loop) | ±0.01% of nominal speed |
| Torque Accuracy (Closed-Loop) | ±5% |
| Transient Overtorque | 170% for 60 s; 220% for 2 s |
| Braking Torque (with resistor) | ≤150% |
| Insulation Resistance | >1 MOhm at 500V DC for 1 minute |
| Dielectric Strength | 3535V DC (earth to power); 5092V DC (control to power) |
| Protection Class | IP54 (lower), IP41 (upper), IP30 (front/sides), IP00 |
| Noise Level | 69.5 dB (86/188/EEC) |
| Operating Temperature | -10°C to +50°C (without derating) |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 5-95% (non-condensing) |
| Operating Altitude | ≤1000 m without derating; 1000-3000 m with 1% derating per 100 m |
| Vibration Resistance | 0.6 gn (10-200 Hz); 1.5 mm peak-to-peak (3-10 Hz) |
| Shock Resistance | 7 gn, 11 ms (EN/IEC 60068-2-27) |
| Dimensions (H x W x D) | 1022 x 360 x 377 mm (40.2 x 14.2 x 14.8 in) |
| Net Weight | 90 kg (198.4 lbs) |
| Gross Weight | 121.56 kg (268.00 lbs) |
| Standards | EN/IEC 61800-3, EN/IEC 61800-5-1, UL Type 1 |
| Certifications | CE, UL, CSA, GOST, NOM 117, C-tick |
Additional Technical Parameters
| Maximum Motor Cable Length (Shielded) | 100 m (328.08 ft) |
| Maximum Motor Cable Length (Unshielded) | 200 m (656.2 ft) |
| Analog Input Sampling Time | 2 ms ±0.5 ms |
| Discrete Input Sampling Time | 2 ms ±0.5 ms |
| STO Response Time | ≤100 ms |
| Relay Output Response Time | 7 ms ±0.5 ms |
| Analog Input Linearity Error | ±0.15% of maximum value |
| Analog Output Linearity Error | ±0.2% |
| Relay Mechanical Life | 100,000 cycles |
| Minimum Switching Current | 3 mA at 24V DC |
Installation Notes
Mount vertically (±10°) using door-mount configuration. Connect 380-480V three-phase supply per local electrical codes. Observe terminal tightening torques: 0.6 N·m for control terminals, 24 N·m for motor terminals, 12 N·m for PA/PB, 41 N·m for PC/PO/PA/+. Maximum motor cable length is 100 m shielded or 200 m unshielded. Maintain operating temperature within -10°C to +50°C without derating. For altitudes above 1000 m, apply 1% current derating per 100 m. The D suffix indicates no DC choke and no graphic terminal. Ensure proper grounding and use the integrated EMC filter for electromagnetic compliance.
FAQs
Q1: What is the motor power rating of this drive?
A1: 110 kW (150 HP) at 380-480V three-phase supply.
Q2: What communication protocols are built in?
A2: Modbus (2-wire RS485) and CANopen.
Q3: What does the D suffix indicate?
A3: The drive is a reinforced version without a DC choke and without a remote graphic terminal.
Specifiche aggiuntive
Scalare (V/f)
Vettore
Alimentato a corrente alternata
Guida all'acquisto
- Conferma il modello esatto, il numero di parte e le specifiche prima di ordinare.
- Verifica la compatibilità con la tua macchina o i sistemi di controllo attuali.
- Contatta sale@etowonauto.com o +8617859788089 per assistenza tecnica.
- Esamina le opzioni di consegna, i tempi di attesa e i requisiti di spedizione.
- Segui le istruzioni del produttore e le migliori pratiche durante l’installazione.
Spedizione e Resi
Gli articoli disponibili in magazzino vengono solitamente spediti lo stesso giorno lavorativo. Per i prodotti non attualmente disponibili, i tempi di spedizione possono variare in base alla disponibilità. La spedizione internazionale è disponibile e i costi di spedizione sono calcolati in base alla destinazione, al peso e al corriere scelto.
Le restituzioni sono accettate entro 30 giorni dal ricevimento, a condizione che gli articoli siano inutilizzati e nelle condizioni originali. Le spese di spedizione per la restituzione sono a carico del cliente. Si prega di contattarci prima di restituire qualsiasi articolo per ricevere l'autorizzazione al reso.
Per maggiori dettagli, si prega di consultare la nostra Politica di Spedizione e Reso.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Spedizione Veloce
Ricambi originali per automazione industriale disponibili per spedizione rapida in tutto il mondo.
-
Resi Facili
Supporto per resi entro 30 giorni con garanzia di 12 mesi per una protezione post-vendita affidabile.
-
Supporto 24/7
Supporto professionale reattivo per aiutare a mantenere operazioni stabili ed efficienti.
-
Autentico e Originale
100% autentico, proveniente direttamente da produttori affidabili di automazione industriale.
Guida tecnica e all'acquisto
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...