Trasforma la tua casa con le ultime soluzioni multi-elettroniche, dall'illuminazione intelligente ai dispositivi controllati tramite voce, tutti progettati per rendere la vita più facile, sicura e connessa. Ottimizza le tue operazioni con il Sistema di Monitoraggio Bently Nevada 3500, che offre il monitoraggio in tempo reale delle vibrazioni e delle condizioni delle macchine per prevenire guasti e massimizzare il tempo di attività.
SKU:TSXCTY2C
Schneider TSXCTY2C Modicon Counter Module 2 Channel
Manufacturer: Schneider
Product No.: TSXCTY2C
Product Type: Counter Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Condividi
- Consegna Veloce
- Assistenza 24 ore su 24, 7 giorni su 7
- Assicurazione della qualità
Descrizione
Schneider Electric TSXCTY2C Modicon Counter Module
Schneider Electric TSXCTY2C | Measurement and counter module for the Modicon Premium and TSX Micro automation platforms. Provides 2 counter channels supporting incremental encoders, absolute encoders, and 2/3-wire proximity sensors. Counting frequency up to 1 MHz. Current sink auxiliary inputs for preset, enable, and read functions. Weight: 0.34 kg (0.75 lb).
Key Features
2 counter channels. Counting frequency up to 1 MHz. Incremental encoder frequency 500 kHz (x1) and 250 kHz (x4). 1 ms cycle time. Current sink auxiliary inputs (preset, enable, read). Compatible with 2/3-wire PNP/NPN proximity sensors, incremental encoders (10-30V totem pole, 5V DC RS422), SSI absolute encoders, and ABE7CPA11 parallel absolute encoders. 24V DC output with 0.5 A nominal current. Thermal overload and short-circuit protection. Zener diode overvoltage protection. Reverse polarity protection.
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | TSXCTY2C |
| Product Line | TSX Micro PLCs / Modicon Premium |
| Product Type | Measurement and Counter Module |
| Number of Channels | 2 |
| Counting Frequency | 1,000,000 Hz (1 MHz) |
| Incremental Encoder Frequency (x1) | 500 kHz |
| Incremental Encoder Frequency (x4) | 250 kHz |
| Cycle Time | 1 ms |
| Input Logic | Current sink auxiliary input (preset, enable, read) |
| Input Compatibility | 2/3-wire PNP/NPN proximity sensors, incremental encoder (10-30V totem pole, 5V DC RS422), SSI absolute encoder, ABE7CPA11 |
| Input Voltage (Sensors) | 24V, 16 mA |
| Input Voltage (Auxiliary) | 24V, 8 mA |
| Input Voltage (Encoder) | 5V, 18 mA |
| Voltage State 1 (Sensors/Aux) | ≥ 11V |
| Voltage State 1 (Encoder) | ≥ 2.4V |
| Voltage State 0 (Encoder) | ≤ 1.2V |
| Voltage State 0 (Sensors/Aux) | ≤ 5V |
| Input Impedance (Encoder) | > 270 Ω at 2.4V; 400 Ω at Un |
| Input Impedance (Sensors) | 1500 Ω at Un |
| Input Impedance (Auxiliary) | 3400 Ω at Un |
| Response Time (Loss of 24V) | < 2.5 ms |
| Response Time (Return of 24V) | < 10 ms |
| Output Voltage | 24V DC (19-30V limits) |
| Nominal Output Current | 0.5 A |
| Maximum Voltage Drop | < 0.5V at state 1 |
| Maximum Leakage Current | 0.1 mA |
| Switching Time | < 0.250 ms |
| Output Protection | Thermal overload, short-circuit, Zener overvoltage, reverse polarity |
| Power Dissipation | 7-10 W |
| Current Consumption | 15 mA @ 24V DC; 850 mA @ 5V DC |
| Local Signaling | RUN (green), I/O fault (red), ERR (red), 2x CH diagnostics (green) |
| Electrical Connection | 1 HE-10 20-pin connector; 2 SUB-D 15 connectors |
| Net Weight | 0.34 kg (0.75 lb) |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 5-95% (non-condensing) |
| Operating Altitude | ≤ 2000 m |
| Protective Treatment | TC |
| Country of Origin | France |
Installation Notes
Mount in Modicon Premium or TSX Micro PLC rack. Connect sensors and encoders via HE-10 20-pin and SUB-D 15 connectors. Verify input voltage limits for each device type: ≤5.5V for encoder, 19-30V for sensors and auxiliary inputs. Use shielded cable for encoder signals to maintain signal integrity at high counting frequencies. Maintain IP20 enclosure and pollution degree 2 environment. LED indicators aid commissioning and fault diagnosis.
Engineering Advantages
1 MHz counting frequency supports high-speed position and motion applications. Dual channels enable simultaneous measurement of two axes. Wide input compatibility covers proximity sensors, incremental encoders, and SSI absolute encoders in a single module. Integrated thermal overload, short-circuit, overvoltage, and reverse polarity protection safeguard the module. 1 ms cycle time ensures fast response for time-critical control. LED diagnostics simplify troubleshooting.
FAQs
Q1: What is the maximum counting frequency?
A1: 1 MHz, with 500 kHz (x1) and 250 kHz (x4) for incremental encoders.
Q2: What input types are supported?
A2: 2/3-wire PNP/NPN proximity sensors, incremental encoders (10-30V totem pole, 5V DC RS422), SSI absolute encoders, and ABE7CPA11 parallel absolute encoders.
Q3: What output does the module provide?
A3: 24V DC output with 0.5 A nominal current, supporting positive logic DC inputs up to 15 kΩ.
Specifiche aggiuntive
- Grigio
- Argento
Scalare (V/f)
Vettore
Alimentato a corrente alternata
Guida all'acquisto
- Conferma il modello esatto, il numero di parte e le specifiche prima di ordinare.
- Verifica la compatibilità con la tua macchina o i sistemi di controllo attuali.
- Contatta sale@etowonauto.com o +8617859788089 per assistenza tecnica.
- Esamina le opzioni di consegna, i tempi di attesa e i requisiti di spedizione.
- Segui le istruzioni del produttore e le migliori pratiche durante l’installazione.
Spedizione e Resi
Gli articoli disponibili in magazzino vengono solitamente spediti lo stesso giorno lavorativo. Per i prodotti non attualmente disponibili, i tempi di spedizione possono variare in base alla disponibilità. La spedizione internazionale è disponibile e i costi di spedizione sono calcolati in base alla destinazione, al peso e al corriere scelto.
Le restituzioni sono accettate entro 30 giorni dal ricevimento, a condizione che gli articoli siano inutilizzati e nelle condizioni originali. Le spese di spedizione per la restituzione sono a carico del cliente. Si prega di contattarci prima di restituire qualsiasi articolo per ricevere l'autorizzazione al reso.
Per maggiori dettagli, si prega di consultare la nostra Politica di Spedizione e Reso.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Spedizione Veloce
Ricambi originali per automazione industriale disponibili per spedizione rapida in tutto il mondo.
-
Resi Facili
Supporto per resi entro 30 giorni con garanzia di 12 mesi per una protezione post-vendita affidabile.
-
Supporto 24/7
Supporto professionale reattivo per aiutare a mantenere operazioni stabili ed efficienti.
-
Autentico e Originale
100% autentico, proveniente direttamente da produttori affidabili di automazione industriale.
Guida tecnica e all'acquisto
-
Can You Restore a DCS Controller Without Downtime?
This article explains field-proven backup and recovery workflows for ABB AC800M DCS controllers. It covers pre-backup...
-
What Makes Live Honeywell Transmitter Replacement Safe?
This article explains how industrial automation teams can replace aging Honeywell transmitters online without a full ...
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...