Trasforma la tua casa con le ultime soluzioni multi-elettroniche, dall'illuminazione intelligente ai dispositivi controllati tramite voce, tutti progettati per rendere la vita più facile, sicura e connessa. Ottimizza le tue operazioni con il Sistema di Monitoraggio Bently Nevada 3500, che offre il monitoraggio in tempo reale delle vibrazioni e delle condizioni delle macchine per prevenire guasti e massimizzare il tempo di attività.
SKU:V18345-1004210001
Positioner V18345-1004210001 ABB | 4-20mA
Manufacturer: ABB
Product No.: V18345-1004210001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Condividi
- Consegna Veloce
- Assistenza 24 ore su 24, 7 giorni su 7
- Assicurazione della qualità
Descrizione
Product Overview
The V18345-1004210001 is an electro-pneumatic positioner from ABB, designed for precise valve control on linear and rotary actuators. Features 4–20 mA two-wire input, HART FSK communication, ATEX EEx nA II T6 protection, and fail-freeze output. Aluminum IP65/NEMA 4X housing. Weight: 1.7 kg. Certified for SIL2 safety loops.
Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | V18345-1004210001 |
| Manufacturer | ABB |
| Type | Electro-Pneumatic Positioner (TZIDC) |
| Input Signal | 4–20 mA two-wire, max 25 mA / 30 V |
| Min Input Current | 3.4 mA (without feedback), start from 3.8 mA |
| Communication | HART 5.1, FSK module, LKS local connector |
| Explosion Protection | ATEX EEx nA II T6 (Zone 2) |
| Output / Safe Position | Fail freeze (single or double acting) |
| Output Range | 0–6 bar (0–90 psi) |
| Supply Pressure | 1.4–6 bar (20–90 psi) |
| Air Consumption | <0.03 kg/h / 0.015 scfm |
| Air Capacity (1.4 bar) | 5.0 kg/h = 3.9 Nm³/h = 2.3 scfm |
| Air Capacity (6 bar) | 13 kg/h = 10 Nm³/h = 6.0 scfm |
| Air Quality | DIN/ISO 8573-1 Class 3 (5 µm, 5 mg/m³, oil 1 mg/m³) |
| Housing Material | Aluminum, varnished, RAL 9005 |
| Protection Class | IP65 / NEMA 4X |
| Pneumatic Connections | G 1/4 or 1/4-18 NPT |
| Electrical Connections | 2 threads 1/2-14 NPT or M20x1.5 |
| Screw Terminals | Max 1.0 mm² (options) / 2.5 mm² (analog signal) |
| Digital Input | 24 V DC (12–30 V DC), max 4 mA |
| Digital Output | 5–11 V DC (NAMUR DIN 19234) |
| Load Voltage (20 mA) | 8.7 V DC (non-Ex) / 9.7 V DC (intrinsically safe) |
| Impedance (20 mA) | 435 Ω (non-Ex) / 485 Ω (intrinsically safe) |
| Angle of Rotation | 25–120° (rotary, optional 270°); 25–60° (linear) |
| Travel Limit | 0–100%, min range >20% |
| Travel Time Prolongation | 0–200 seconds per direction |
| Characteristic Deviation | ≤0.5% |
| Tolerance Band | 0.3–10% adjustable |
| Dead Band | 0.1–10% adjustable |
| Resolution | >4000 steps |
| Sample Rate | 20 ms |
| Temperature Influence | ≤0.5% per 10°C |
| Vibration Influence | ≤±1% up to 10 g and 80 Hz |
| Seismic Compliance | DIN/IEC 68-3-3 Class III |
| Ambient Temperature | -40°C to +85°C |
| Humidity (Operational) | 95% annual average, condensation permissible |
| Humidity (Transport/Storage) | 75% annual average, non-condensing |
| Safety | SIL2 safety loops |
| Approvals | ATEX, FM, CSA, IECEx |
| Weight | 1.7 kg |
Installation & Maintenance
Mounting
Mount to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Integral mounting ready. Mechanical position indicator provides visual feedback. Mounting orientation has no effect on performance.
Air Supply
Use instrument air free of oil, water, and dust per DIN/ISO 8573-1 Class 3: max particle 5 µm, density 5 mg/m³, oil 1 mg/m³, dew point 10 K below operating temperature. Do not exceed actuator max operating pressure.
Hazardous Area Installation
ATEX EEx nA II T6 (Zone 2) approved. Ambient temperature limits: T4 -40°C to +85°C, T5 -40°C to +65°C, T6 -40°C to +50°C. Also certified for FM/CSA intrinsically safe and IECEx Ex ib IIC T6 applications.
Engineering Advantages
Fail-Freeze Safety
On electrical power failure, the actuator blocks in its last position (fail freeze). Ensures process continuity and safe operation in critical applications. Certified for SIL2 safety loops.
ATEX Zone 2 Protection
ATEX EEx nA II T6 certification enables installation in Zone 2 hazardous areas. Also certified for FM/CSA intrinsically safe and IECEx Ex ib IIC T6 applications.
Precise Valve Control
Resolution >4000 steps with 20 ms sample rate. Characteristic deviation ≤0.5%. Freely configurable characteristic curves with 20 reference points. HART FSK communication for remote diagnostics.
Technical FAQs
Q1: What is the fail-safe behavior on electrical power failure?
A1: Fail freeze. The actuator blocks in its last position on loss of electrical power. Air is vented from the actuator or the actuator is blocked.
Q2: What explosion protection does this model provide?
A2: ATEX EEx nA II T6 (Zone 2). Also certified for FM/CSA intrinsically safe and IECEx Ex ib IIC T6.
Q3: What communication protocol does this positioner use?
A3: HART 5.1 via FSK module over the 20 mA signal line. Also supports LKS local communication interface.
Specifiche aggiuntive
- Argento
Scalare (V/f)
Vettore
Alimentato a corrente alternata
Guida all'acquisto
- Conferma il modello esatto, il numero di parte e le specifiche prima di ordinare.
- Verifica la compatibilità con la tua macchina o i sistemi di controllo attuali.
- Contatta sale@etowonauto.com o +8617859788089 per assistenza tecnica.
- Esamina le opzioni di consegna, i tempi di attesa e i requisiti di spedizione.
- Segui le istruzioni del produttore e le migliori pratiche durante l’installazione.
Spedizione e Resi
Gli articoli disponibili in magazzino vengono solitamente spediti lo stesso giorno lavorativo. Per i prodotti non attualmente disponibili, i tempi di spedizione possono variare in base alla disponibilità. La spedizione internazionale è disponibile e i costi di spedizione sono calcolati in base alla destinazione, al peso e al corriere scelto.
Le restituzioni sono accettate entro 30 giorni dal ricevimento, a condizione che gli articoli siano inutilizzati e nelle condizioni originali. Le spese di spedizione per la restituzione sono a carico del cliente. Si prega di contattarci prima di restituire qualsiasi articolo per ricevere l'autorizzazione al reso.
Per maggiori dettagli, si prega di consultare la nostra Politica di Spedizione e Reso.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Spedizione Veloce
Ricambi originali per automazione industriale disponibili per spedizione rapida in tutto il mondo.
-
Resi Facili
Supporto per resi entro 30 giorni con garanzia di 12 mesi per una protezione post-vendita affidabile.
-
Supporto 24/7
Supporto professionale reattivo per aiutare a mantenere operazioni stabili ed efficienti.
-
Autentico e Originale
100% autentico, proveniente direttamente da produttori affidabili di automazione industriale.
Guida tecnica e all'acquisto
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...