Trasforma la tua casa con le ultime soluzioni multi-elettroniche, dall'illuminazione intelligente ai dispositivi controllati tramite voce, tutti progettati per rendere la vita più facile, sicura e connessa. Ottimizza le tue operazioni con il Sistema di Monitoraggio Bently Nevada 3500, che offre il monitoraggio in tempo reale delle vibrazioni e delle condizioni delle macchine per prevenire guasti e massimizzare il tempo di attività.
SKU:1756-L72S
Logix5572S PAC Controller | Allen-Bradley 1756-L72S
Manufacturer: Allen-Bradley
Product No.: 1756-L72S
Product Type: Safety Processor
Product Origin: USA
Payment:T/T, Western Union
Weight: 250g
Shipping port: Xiamen
Warranty: 12 months
Condividi
- Consegna Veloce
- Assistenza 24 ore su 24, 7 giorni su 7
- Assicurazione della qualità
Descrizione
Product Overview
The Allen-Bradley 1756-L72S is a high-performance GuardLogix 5570 Programmable Automation Controller (PAC) engineered by Rockwell Automation. This dual-processor module integrates standard and safety control functions within a single project file, maximizing processing capabilities for motion and complex logic applications. Featuring 4 MB of standard user memory and 2 MB of dedicated safety memory, it serves as the primary controller alongside a required 1756-L7SP (or 1756-L7SPK) safety partner module to achieve stringent SIL 3, PLe, and Cat. 4 safety ratings. Weighing only 0.55 lbs (0.25 kg), this batteryless processor utilizes modern energy storage modules (ESM) to maintain volatile memory security without maintenance downtime.
Key Advantages
- Unified Control Architecture: Combines standard machine control and functional safety systems into one unified hardware slot and application software project.
- Battery-Free Operation: Equipped with an integrated 1756-ESMCAP energy storage capacitor, eliminating the environmental impact and replacement schedules associated with traditional lithium batteries.
- Massive I/O Scalability: Supports up to 128,000 digital I/O points and up to 4,000 analog I/O points across local backplanes or distributed industrial networks.
- Lightweight Slot Integration: Weighing just 0.55 lbs, the open-style enclosure installs effortlessly into any slot of a ControlLogix 1756 chassis, allowing multiple processors to co-exist in the same frame.
- Robust Non-Volatile Memory: Ships with a pre-installed 1 GB 1784-SD1 Secure Digital card, ensuring secure firmware back-up and boot loading, expandable up to 2 GB via 1784-SD2.
Technical Specifications
| Model Number | 1756-L72S (Logix5572S) |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Series / Family | GuardLogix 5570 / ControlLogix |
| Standard User Memory | 4 MB |
| Safety Memory | 2 MB |
| I/O Memory | 0.98 MB |
| Safety Partner Module | 1756-L7SP / 1756-L7SPK (Required) |
| Non-Volatile Storage | 1 GB SD Card (1784-SD1 included, supports up to 2 GB) |
| Net Weight | 0.55 lbs (0.25 kg) |
| Current Draw | 800 mA @ 5.1V DC / 5 mA @ 1.2V DC |
| Power & Thermal Dissipation | 2.5 Watts / 8.5 BTU per hour |
| Isolation Voltage | 30V Continuous (Basic Insulation) |
Quick Installation Tips
- Slot Layout Planning: The 1756-L72S is an open-style module that can be inserted into any standard slot of a 1756 ControlLogix chassis. However, it must be paired in a neighboring slot with its safety partner, the 1756-L7SP module. Despite their minimal combined weight (each processor is only 0.55 lbs), ensure both modules are locked into the backplane connectors firmly.
- Chassis and Power Compatibility: This processor is fully compatible with standard or conformally coated chassis assemblies (e.g., 1756-A4, 1756-A7, 1756-A10, up to 1756-A17 standard/K-series) and can be powered by standard industrial power supplies like the 1756-PA75 or 1756-PB75 ranges.
- Energy Storage Selection: The unit comes standard with the integrated 1756-ESMCAP capacitor. If your site applications prohibit USB configuration or SD card utilization for enhanced security, consider replacing it with the 1756-ESMNRM module. For systems requiring immediate power cuts without residual clock uptime, select the 1756-ESMNSE option.
Technical FAQs
Q1: Is the safety partner module configured separately from the 1756-L72S primary module?
A1: No. The safety partner controller (1756-L7SP) is automatically configured by the system. Both standard and safety routines are developed and compiled within a single, integrated project environment, drastically cutting engineering time compared to isolated safety solutions.
Q2: What communication capabilities are built onto the front faceplate of the module?
A2: The 1756-L72S features a built-in USB port intended for programming, configuration, firmware updates, and rapid online diagnostics. For real-time plant network communication and safety I/O data links, separate EtherNet/IP, ControlNet, or DeviceNet communication bridge modules must be added to the chassis.
Q3: How many tasks can this processor handle concurrently?
A3: The controller supports a maximum of 31 standard tasks and 1 dedicated safety task, with a high capacity of up to 100 separate logic programs allowed per single task. Event tasks can be triggered by all supported system event types.
Specifiche aggiuntive
Scalare (V/f)
Vettore
Alimentato a corrente alternata
Guida all'acquisto
- Conferma il modello esatto, il numero di parte e le specifiche prima di ordinare.
- Verifica la compatibilità con la tua macchina o i sistemi di controllo attuali.
- Contatta sale@etowonauto.com o +8617859788089 per assistenza tecnica.
- Esamina le opzioni di consegna, i tempi di attesa e i requisiti di spedizione.
- Segui le istruzioni del produttore e le migliori pratiche durante l’installazione.
Spedizione e Resi
Gli articoli disponibili in magazzino vengono solitamente spediti lo stesso giorno lavorativo. Per i prodotti non attualmente disponibili, i tempi di spedizione possono variare in base alla disponibilità. La spedizione internazionale è disponibile e i costi di spedizione sono calcolati in base alla destinazione, al peso e al corriere scelto.
Le restituzioni sono accettate entro 30 giorni dal ricevimento, a condizione che gli articoli siano inutilizzati e nelle condizioni originali. Le spese di spedizione per la restituzione sono a carico del cliente. Si prega di contattarci prima di restituire qualsiasi articolo per ricevere l'autorizzazione al reso.
Per maggiori dettagli, si prega di consultare la nostra Politica di Spedizione e Reso.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Spedizione Veloce
Ricambi originali per automazione industriale disponibili per spedizione rapida in tutto il mondo.
-
Resi Facili
Supporto per resi entro 30 giorni con garanzia di 12 mesi per una protezione post-vendita affidabile.
-
Supporto 24/7
Supporto professionale reattivo per aiutare a mantenere operazioni stabili ed efficienti.
-
Autentico e Originale
100% autentico, proveniente direttamente da produttori affidabili di automazione industriale.
Guida tecnica e all'acquisto
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...
-
How to streamline industrial automation spare parts import clearance?
This guide delivers a data-driven framework for sourcing and clearing industrial automation spare parts, covering PLC...
-
How Fast Must DCS Switchover Be to Prevent Costly Process Upsets?
This article presents quantified DCS redundancy strategies using real 2024–2025 plant data. It details sub-100ms swit...
-
Why Is Explosion-Proof DCS Critical for Chemical Plant Safety?
This technical article examines how optimized multi-vendor explosion-proof DCS architectures address critical safety ...
-
How to restore Allen‑Bradley PLCs to 99.8% performance?