Trasforma la tua casa con le ultime soluzioni multi-elettroniche, dall'illuminazione intelligente ai dispositivi controllati tramite voce, tutti progettati per rendere la vita più facile, sicura e connessa. Ottimizza le tue operazioni con il Sistema di Monitoraggio Bently Nevada 3500, che offre il monitoraggio in tempo reale delle vibrazioni e delle condizioni delle macchine per prevenire guasti e massimizzare il tempo di attività.
SKU:IC693CBL304
IC693CBL304 GE Series 90-30 PCM300 Splitter Cable 1ft
Manufacturer: General Electric
Product No.: IC693CBL304
Product Type: Expansion Cable
Product Origin: USA
Payment:T/T, Western Union
Weight: 140g
Shipping port: Xiamen
Warranty: 12 months
Condividi
- Consegna Veloce
- Assistenza 24 ore su 24, 7 giorni su 7
- Assicurazione della qualità
Descrizione
Product Overview
The GE Fanuc IC693CBL304 is a specialized, highly compact 1-foot (0.3-meter) port expansion "Wye" cable engineered exclusively for the Series 90-30 Programmable Coprocessor Module (IC693PCM300). This ultra-lightweight adapter, weighing only 0.14 kg (0.31 lbs), serves as a signal splitter, separating combined RS-232 and RS-485 communications from a single physical port on the PCM host module into two distinct, isolated connections. Equipped with a space-saving right-angle male connector on the module side and dual-female connectors on the output end, it delivers seamless signal routing without adding physical strain or bulky weight to your PLC rack assembly.
Key Advantages
- Dual-Protocol Separation: Effortlessly splits combined lines to deliver dedicated RS-232 signals on one leg and RS-485 signals on the other, allowing simultaneous dual-port operation.
- Right-Angle & Compact Design: The module-end connector features a right-angle profile, and at a minimal weight of just 0.14 kg, it fits neatly into tight control panels and shallow enclosures without straining delicate ports.
- Continuous Shielding: Encased in high-quality, continuous electrical shielding to block electromagnetic interference (EMI) and preserve communication speeds in noisy industrial environments.
- 90/70 to 90/30 Compatibility: Standardizes physical connections, making the Series 90/70 PCM interface fully compatible with Series 90/30 PCM module hardware.
Technical Specifications
| Model Number | IC693CBL304 |
| Brand / Series | GE Fanuc / Series 90-30 |
| Cable Type | Port Expansion (Wye / Splitter) Cable |
| Module Compatibility | IC693PCM300 (Programmable Coprocessor Module) |
| Cable Length | 1 foot (approx. 30 cm) |
| Connector 1 (Module End) | Right-Angle Male Connector |
| Connector 2 (Device End) | Dual-Female Connectors (Port 1 and Port 2) |
| Shielding Type | Continuous high-coverage shield |
| Net Weight | 0.14 kg (0.31 lbs) |
| Max Units Per Module | One Wye cable per PCM module |
| Lifecycle Status | Discontinued / Obsolete (Available as legacy support) |
Quick Installation & Safety Tips
- Equal Potential Grounding: Ensure that the IC693CBL304 cable shielding, the host PCM module, and the PLC baseplate are all tied to the same electrical ground potential. Caution: Ground loops or mismatched voltage potentials can permanently damage connected programming terminals or internal module electronics.
- Align Right-Angle Connector Carefully: When plugging the right-angle male end into the PCM module, line up the pins smoothly before applying pressure to avoid bending the pins in the module's communication port.
- Port Identification: The dual-female end splits the signals into Port 1 and Port 2. Refer to your system program configuration to ensure the RS-232 serial link and RS-485 serial link are mapped and connected to the correct corresponding output ports.
Technical FAQs
Q1: Why does this cable split into two connections from a single physical port?
A1: The IC693PCM300 module consolidates both RS-232 and RS-485 pinouts into a single high-density connector to save space. The IC693CBL304 Wye cable acts as a hardware splitter, separating these signal lines into two independent physical ports (Port 1 and Port 2) to allow simultaneous connections.
Q2: What happens if the cable and baseplate are not grounded at the same potential?
A2: Failure to ground the system at equal ground potential will lead to stray currents flowing through the communications line. This can cause communication faults, signal corruption, or catastrophic hardware damage to the PCM module, the cable, and connected programmer devices.
Q3: Is the IC693CBL304 cable included when I buy the IC693PCM300 module?
A3: Yes, this Wye cable was originally supplied standard inside the box with the IC693PCM300 module. However, because it can wear out or get lost during field servicing, it is also available as an individual replacement accessory.
Specifiche aggiuntive
Scalare (V/f)
Vettore
Alimentato a corrente alternata
Guida all'acquisto
- Conferma il modello esatto, il numero di parte e le specifiche prima di ordinare.
- Verifica la compatibilità con la tua macchina o i sistemi di controllo attuali.
- Contatta sale@etowonauto.com o +8617859788089 per assistenza tecnica.
- Esamina le opzioni di consegna, i tempi di attesa e i requisiti di spedizione.
- Segui le istruzioni del produttore e le migliori pratiche durante l’installazione.
Spedizione e Resi
Gli articoli disponibili in magazzino vengono solitamente spediti lo stesso giorno lavorativo. Per i prodotti non attualmente disponibili, i tempi di spedizione possono variare in base alla disponibilità. La spedizione internazionale è disponibile e i costi di spedizione sono calcolati in base alla destinazione, al peso e al corriere scelto.
Le restituzioni sono accettate entro 30 giorni dal ricevimento, a condizione che gli articoli siano inutilizzati e nelle condizioni originali. Le spese di spedizione per la restituzione sono a carico del cliente. Si prega di contattarci prima di restituire qualsiasi articolo per ricevere l'autorizzazione al reso.
Per maggiori dettagli, si prega di consultare la nostra Politica di Spedizione e Reso.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Spedizione Veloce
Ricambi originali per automazione industriale disponibili per spedizione rapida in tutto il mondo.
-
Resi Facili
Supporto per resi entro 30 giorni con garanzia di 12 mesi per una protezione post-vendita affidabile.
-
Supporto 24/7
Supporto professionale reattivo per aiutare a mantenere operazioni stabili ed efficienti.
-
Autentico e Originale
100% autentico, proveniente direttamente da produttori affidabili di automazione industriale.
Guida tecnica e all'acquisto
-
Hybrid DCS/PLC: Digital Twin Fix?
This technical article examines how hybrid ABB DCS and Allen‑Bradley PLC architectures overcome data isolation and co...
-
Why Do 68% of Turbine False Trips Come from TSI-DCS Signal Mismatch
This technical article examines the critical compatibility challenges between Bently Nevada 3300/3500 TSI probes and ...
-
Cutting Multi-Vendor Downtime by 32% – Is Your Plant Ready?
Emerson Boundless Automation unifies data from ABB DCS, Allen-Bradley PLC, and GE Fanuc controllers without gateways....
-
Can Hybrid PLC-TSI Replace Expensive DCS Systems?
Small and medium refineries face critical monitoring bottlenecks with manual inspections causing 8-hour fault detecti...
-
What is the Real Cost of Corrosion on Factory Automation?
Standard automation hardware fails rapidly in corrosive heavy industries, causing significant downtime and mainten...
-
Can DCS-PLC-TSI Synergy Cut Refinery Furnace Energy Loss by 7%?
This article explains how synchronizing Distributed Control Systems, Programmable Logic Controllers, and Turbine Supe...
