Trasforma la tua casa con le ultime soluzioni multi-elettroniche, dall'illuminazione intelligente ai dispositivi controllati tramite voce, tutti progettati per rendere la vita più facile, sicura e connessa. Ottimizza le tue operazioni con il Sistema di Monitoraggio Bently Nevada 3500, che offre il monitoraggio in tempo reale delle vibrazioni e delle condizioni delle macchine per prevenire guasti e massimizzare il tempo di attività.
SKU:IC670MDL930
IC670MDL930 GE Fanuc Field Control 8 Point Relay Module
Manufacturer: General Electric
Product No.: IC670MDL930
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Condividi
- Consegna Veloce
- Assistenza 24 ore su 24, 7 giorni su 7
- Assicurazione della qualità
Descrizione
Product Overview
The GE Fanuc IC670MDL930 is an 8-point individually isolated discrete relay output module belonging to the Field Control I/O system. Engineered for high-density, reliable switching in industrial automation and process control architectures, this module provides flexible AC/DC load driving for field devices such as solenoids, motor starters, indicator lights, and actuators.
Featuring a total of eight channels organized into six (6) Form A (Normally Open) contacts and two (2) Form C (SPDT / Normally Open & Normally Closed) contacts, the IC670MDL930 delivers channel-to-channel isolation with built-in RC snubber transient protection (R=47.5 Ω, C=0.022 µF). With a compact design weighing approximately 0.30 kg (0.66 lbs), it operable across 5–30 V DC, 31–125 V DC, and 5–265 V AC, supporting up to 2.0 A continuous load per channel (16 A maximum per module) while drawing a maximum of 313 mA from the Bus Interface Unit (BIU) logic supply.
Core Technical Advantages
- Individual Channel Isolation: Each output contact is independently isolated (250 VAC continuous, 1500 VAC for 1 min), preventing ground loops and protecting logic-side electronics.
- Mixed Contact Configuration: Integrates six Form A (N.O.) and two Form C (N.O./N.C.) silver-alloy contacts for versatile logic and safety circuit wiring.
- Integrated RC Snubber Suppression: Built-in snubber networks across contacts mitigate high-frequency voltage spikes caused by inductive load switching without external components.
- Comprehensive Diagnostic LEDs: Features channel-level status LEDs alongside power indicators to simplify field troubleshooting and signal verification.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | GE Fanuc |
| Catalog Part Number | IC670MDL930 |
| Product Family | Field Control I/O System |
| Module Type | Isolated Discrete Relay Output Module |
| Number of Channels | 8 channels (Individual channel isolation) |
| Contact Forms | 6 × Form A (N.O.) / 2 × Form C (N.O. & N.C.) |
| Nominal Operating Voltages | 5 / 24 / 125 V DC; 120 / 240 V AC (47–63 Hz) |
| Operating Voltage Ranges | 0 to 130 V DC / 0 to 265 V AC |
| Maximum Load Current (AC) | 2.0 A per point (5 to 265 V AC) |
| Maximum Load Current (DC) | 2.0 A per point (5 to 30 V DC); 0.2 A per point (31 to 125 V DC) |
| Total Module Current Capacity | 16 A maximum (resistive load) |
| Minimum Load Current | 10 mA per point |
| Maximum Inrush Current | 5 A for 20 ms |
| BIU Current Consumption | 313 mA maximum from BIU logic supply |
| Relay Technology & Material | Fixed coil, moving armature; Silver Alloy contacts (0.2 Ω resistance) |
| On / Off Response Time | 10 ms maximum transition time |
| Maximum Switching Frequency | 20 cycles/minute (inductive loads) |
| Contact Life Expectancy | Mechanical: 20 × 10⁶ ops; Electrical: 10⁵ ops at rated resistive load |
| Internal Protection & Fusing | RC Snubber (R=47.5 Ω, C=0.022 µF); No internal fuse |
| Isolation Voltage | 250 VAC continuous / 1500 VAC for 1 min (Input to Logic / Group to Group) |
| Shipping Weight | Approx. 0.30 kg (0.66 lbs) |
Installation & Wiring Guidelines
- Field Base Mounting: Snap the IC670MDL930 module onto the matching Field Control terminal base, ensuring backplane connectors seal firmly to enable BIU power and data flow.
- External Power Distribution: Connect an external AC or DC field power source to drive loads connected through relay contacts. Ensure proper external fusing since the module does not contain internal fuses.
- Inductive Load Protection: While built-in RC snubbers suppress standard noise transients, high-inductance DC loads should utilize secondary flyback diodes installed directly across the load terminals.
Technical FAQs
Q1: What are the current rating limits for DC loads on the GE Fanuc IC670MDL930?
A1: Each contact supports 2.0 A for low-voltage DC (5 to 30 V DC), but drops to 0.2 A max for high-voltage DC applications (31 to 125 V DC).
Q2: Does the IC670MDL930 module provide individual channel isolation?
A2: Yes, all 8 channels are individually isolated up to 250 VAC continuous (1500 VAC for 1 minute) between groups, logic, and frame ground.
Q3: What power does the module draw from the Field Control BIU backplane?
A3: The module draws up to 313 mA from the Bus Interface Unit (BIU) power supply to energize the relay coils.
Specifiche aggiuntive
Scalare (V/f)
Vettore
Alimentato a corrente alternata
Guida all'acquisto
- Conferma il modello esatto, il numero di parte e le specifiche prima di ordinare.
- Verifica la compatibilità con la tua macchina o i sistemi di controllo attuali.
- Contatta sale@etowonauto.com o +8617859788089 per assistenza tecnica.
- Esamina le opzioni di consegna, i tempi di attesa e i requisiti di spedizione.
- Segui le istruzioni del produttore e le migliori pratiche durante l’installazione.
Spedizione e Resi
Gli articoli disponibili in magazzino vengono solitamente spediti lo stesso giorno lavorativo. Per i prodotti non attualmente disponibili, i tempi di spedizione possono variare in base alla disponibilità. La spedizione internazionale è disponibile e i costi di spedizione sono calcolati in base alla destinazione, al peso e al corriere scelto.
Le restituzioni sono accettate entro 30 giorni dal ricevimento, a condizione che gli articoli siano inutilizzati e nelle condizioni originali. Le spese di spedizione per la restituzione sono a carico del cliente. Si prega di contattarci prima di restituire qualsiasi articolo per ricevere l'autorizzazione al reso.
Per maggiori dettagli, si prega di consultare la nostra Politica di Spedizione e Reso.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Spedizione Veloce
Ricambi originali per automazione industriale disponibili per spedizione rapida in tutto il mondo.
-
Resi Facili
Supporto per resi entro 30 giorni con garanzia di 12 mesi per una protezione post-vendita affidabile.
-
Supporto 24/7
Supporto professionale reattivo per aiutare a mantenere operazioni stabili ed efficienti.
-
Autentico e Originale
100% autentico, proveniente direttamente da produttori affidabili di automazione industriale.
Guida tecnica e all'acquisto
-
Does New GE Fanuc 90-30 Backplane Stabilize Cement Kilns?
This technical article examines how brand-new GE Fanuc 90-30 PLC backplane components deliver measurable reliability ...
-
Why 28% of Gas Turbine Trips Stem from Monitoring Failures?
Combined cycle gas turbines demand micron-level shaft monitoring to prevent vibration resonance and unplanned outages...
-
Can ABB AC500 redundant power eliminate mill downtime?
This technical article examines how ABB AC500 redundant power modules resolve unplanned downtime caused by voltage...
-
Is Your Wastewater Plant Ready for a Data-Driven Upgrade?
This technical article examines the operational bottlenecks of legacy wastewater treatment automation and presents a ...
-
Can Eddy-Current Probes Prevent LNG Compressor Shutdowns?
This technical article examines how Bently Nevada eddy-current proximity probes provide high-precision vibration...
-
Can SIL 3 PLCs Really Slash $1M in Annual Offshore Maintenance?
This technical article examines how Allen‑Bradley GuardPLC SIL 3 safety controllers reduce unplanned offshore downtim...