  • Manufacturer: HIMA

  • Product No.: F7553

  • Product Type: Coupling Module

  • Product Origin: DE

  • Payment:T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Politica di reso di 30 giorni · Garanzia di 12 mesi
  • Consegna Veloce
  • Assistenza 24 ore su 24, 7 giorni su 7
  • Assicurazione della qualità

Descrizione

Product Overview

The HIMA F7553 is an industrial-grade Coupling Module designed specifically for integration within the HIMA H51q Programmable Electronic System (PES) architecture. Configured with Assembly kit B 9302, this module enables reliable inter-rack signal coupling and system-level communication management. A key feature of the F7553 is its integrated logic for watchdog signal switch-off, which allows system engineers to safely isolate or bypass watchdog monitoring lines during specialized diagnostic, testing, or maintenance routines. Designed with a physical shipping weight of approximately 2 kg (4.41 lbs), the unit features a compact 4 TE width form factor, optimizing valuable backplane rack space in high-density safety instrumented system (SIS) installations.

As shown in the product image, the module comprises a standard eurocard circuit board with an integrated front plate, featuring status indicators, DIP/toggle control switches for watchdog selection, and standard dual-bus operating voltage support (5 V DC at 600 mA and 24 V DC at 750 mA) for stable power distribution across the subrack assembly.

Core Technical Advantages

  • Watchdog Signal Control: Features dedicated circuitry to switch off watchdog signals, facilitating targeted fault testing and maintenance without tripping surrounding system loops.
  • Assembly Kit B 9302 Integration: Factory-configured with Assembly kit B 9302 to ensure full hardware compatibility and plug-and-play installation in H51q safety racks.
  • Compact 4 TE Footprint: Requires only 4 TE (3/4 inch / 20.32 mm) of rack space, preserving subrack capacity for additional I/O and communication modules.
  • Dual DC Power Support: Utilizes regulated 5 V DC logic supply along with 24 V DC auxiliary power to ensure stable signaling and noise immunity under industrial operating conditions.

Technical Specifications

Parameter Attribute Factory Specification Data
Brand / Manufacturer HIMA
Part / Model Number F7553 (F 7553)
Product Type Coupling Module
Assembly Kit Version Assembly kit B 9302
Target Safety System HIMA PES H51q Controller Architecture
Special Functionality With switch-off mechanism for watchdog signal (WD / WD-SEL)
Space Requirement 4 TE (Width)
Operating Voltage / Current (Logic) 5 V DC @ 600 mA
Operating Voltage / Current (Auxiliary) 24 V DC @ 750 mA
Shipping Weight 2.0 kg (4.41 lbs)
Form Factor / Mounting Subrack Eurocard Module / Backplane Slot Insertion
Operating Temperature 0°C to +60°C (32°F to 140°F)
Condition / Warranty New & Original in Factory Packaging | 12-Month Factory Warranty

Functional & Hardware Description

The HIMA F7553 Coupling Module provides bus coupling functions within H51q safety controller racks. Built around the Assembly kit B 9302 configuration, it includes hardware jumpers and DIP switches to manage watchdog signal pathways across redundant controller subracks. The module consumes 600 mA on the internal 5 V DC bus for onboard logic operation and 750 mA on the 24 V DC power bus for signal transmission drive, ensuring robust operation during system diagnostics and normal safety monitor execution.

Installation & Maintenance Guidelines

Ensure cabinet power is turned off or isolated prior to module insertion. Align the F7553 card edges with the designated 4 TE slot guide rails in the H51q rack. Gently push the module firmly into the backplane connectors and tighten the top and bottom front panel retaining screws to secure grounding and physical alignment.

Technical FAQs

Q: What system is the HIMA F7553 designed for?
A: The F7553 is designed for the HIMA H51q Programmable Electronic System (PES).

Q: What is the slot width requirement for this module?
A: The module requires 4 TE of rack width space.

Q: What are the primary power supply requirements?
A: It requires 5 V DC at 600 mA and 24 V DC at 750 mA.

🏷️ Tags: Coupling Module

Scalare (V/f)

Vettore

Alimentato a corrente alternata

  • Conferma il modello esatto, il numero di parte e le specifiche prima di ordinare.
  • Verifica la compatibilità con la tua macchina o i sistemi di controllo attuali.
  • Contatta sale@etowonauto.com o +8617859788089 per assistenza tecnica.
  • Esamina le opzioni di consegna, i tempi di attesa e i requisiti di spedizione.
  • Segui le istruzioni del produttore e le migliori pratiche durante l’installazione.

Gli articoli disponibili in magazzino vengono solitamente spediti lo stesso giorno lavorativo. Per i prodotti non attualmente disponibili, i tempi di spedizione possono variare in base alla disponibilità. La spedizione internazionale è disponibile e i costi di spedizione sono calcolati in base alla destinazione, al peso e al corriere scelto.

Le restituzioni sono accettate entro 30 giorni dal ricevimento, a condizione che gli articoli siano inutilizzati e nelle condizioni originali. Le spese di spedizione per la restituzione sono a carico del cliente. Si prega di contattarci prima di restituire qualsiasi articolo per ricevere l'autorizzazione al reso.

Per maggiori dettagli, si prega di consultare la nostra Politica di Spedizione e Reso.

Visualizza dettagli completi

GARANTISCI PRESTAZIONI AFFIDABILI DELLA MACCHINARIA

Trasforma la tua casa con le ultime soluzioni multi-elettroniche, dall'illuminazione intelligente ai dispositivi controllati tramite voce, tutti progettati per rendere la vita più facile, sicura e connessa. Ottimizza le tue operazioni con il Sistema di Monitoraggio Bently Nevada 3500, che offre il monitoraggio in tempo reale delle vibrazioni e delle condizioni delle macchine per prevenire guasti e massimizzare il tempo di attività.