Trasforma la tua casa con le ultime soluzioni multi-elettroniche, dall'illuminazione intelligente ai dispositivi controllati tramite voce, tutti progettati per rendere la vita più facile, sicura e connessa. Ottimizza le tue operazioni con il Sistema di Monitoraggio Bently Nevada 3500, che offre il monitoraggio in tempo reale delle vibrazioni e delle condizioni delle macchine per prevenire guasti e massimizzare il tempo di attività.
SKU:1756-IM16I
Allen-Bradley 1756-IM16I 16 Channel Isolated AC Input
Manufacturer: Allen-Bradley
Product No.: 1756-IM16I
Product Type: AC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Condividi
- Consegna Veloce
- Assistenza 24 ore su 24, 7 giorni su 7
- Assicurazione della qualità
Descrizione
Product Overview
The Allen-Bradley 1756-IM16I is a premium, heavy-duty 16-point isolated AC digital input module belonging to the high-performance ControlLogix automation platform. Engineered for challenging industrial environments with diverse electrical grids, this module provides complete point-to-point isolation across all 16 channels, operating within a nominal voltage category of 240 Volts AC (159 to 265 VAC range). Weighing approximately 0.30 kg (0.66 lbs), this chassis-based processor card monitors high-voltage field statuses, executes precise Change-of-State (COS) tracking, and protects the core PLC backplane from dangerous multi-phase cross-faults or erratic voltage spikes.
Core Technical Advantages
- Per-Point Individual Isolation: Features 16 completely independent isolated channel grids, permitting the simultaneous monitoring of distinct AC phases or separate field power sources on a single module without phase short-circuit risks.
- Programmable Logic Filter Times: Supports highly customizable input delay filters (selectable up to 18 ms) combined with rapid hardware response times to successfully suppress contact bounce and high-frequency line noise.
- Advanced Thermal Derating Matrix: Optimized to safely dissipate up to 5.8 Watts at 60 degrees Celsius, providing robust multi-channel configuration charts to handle continuous high-temperature field operations with maximum stability.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation (ControlLogix System) |
| Model Part Number | 1756-IM16I (UPC 10612598171344) |
| Gross Weight | 0.30 kg (0.66 lbs) |
| Module Category | Isolated Digital AC Input Module |
| Discrete Input Count | 16 Individually Isolated Inputs (Point-to-Point Isolation) |
| Nominal Voltage Category | 240 Volts AC (50 / 60 Hz operating frequency) |
| Continuous Operating Range | 159 to 265 Volts AC (47 to 63 Hz frequency bandwidth) |
| On-State Current Threshold | 5 mA minimum at 159 VAC / 13 mA maximum at 265 VAC |
| Off-State Threshold Limits | Maximum 40 Volts AC / Maximum 2.5 mA leakage current |
| Maximum Inrush Current | 250 mA peak inrush loading capability |
| Backplane Current Requirements | 100 mA at 5 VDC / 3 mA at 24 VDC (Total Bus Power: 0.58 Watts) |
| Thermal / Power Dissipation | 5.8 Watts maximum power loss / 19.78 BTU/hour thermal dissipation |
| Compatible Terminal Housing | 36-Pin Removable Terminal Blocks (1756-TBCH or 1756-TBS6H) |
Installation & Engineering Guide
- Chassis Placement & Insertion: Ensure the primary system power supply is completely isolated before beginning installation. Align the 0.30 kg hardware frame within the selected slot guides of the 1756 ControlLogix chassis, pushing it backward firmly until the top and bottom retention clips snap completely over the structural chassis rail tabs.
- 36-Pin RTB Wiring Configurations: Terminate your 240V AC field inputs through an approved 1756-TBCH (extended clamp) or 1756-TBS6H (spring clamp) 36-pin removable terminal block. Because each channel is fully isolated, always run both the active signal line and its respective neutral return line directly to the designated channel terminal pair.
- Operating Environment Derating: Monitor your local enclosure temperature guidelines closely. When executing full system density, all 16 channels can remain ON up to 30 degrees Celsius at 265 VAC; however, if operating at 40 degrees Celsius, limit simultaneous active channels to 8 points max, or derate the operational input limit down to 242 VAC at 60 degrees Celsius with all channels active.
Technical FAQs
Q1: How is the total execution delay calculated for the 1756-IM16I AC input paths?
A1: The total turnaround delay from screw to backplane is a combination of native hardware circuit latency and user-selected filter times. Going from Off-to-On, it equals the 10 ms max hardware delay plus a selectable 1 or 2 ms filter. Going from On-to-Off, it is an 8 ms max hardware delay plus a selectable 9 or 18 ms filter block.
Q2: What is the main advantage of point-to-point isolation on this specific digital input card?
A2: Unlike standard grouped inputs that share a common return bus, per-point isolation provides a completely separate circuit for each of the 16 paths. This allows you to mix different AC voltage phases or feed signals from entirely separate safety substations into a single physical card without risk of catastrophic cross-phase failure.
Q3: Does the lightweight 0.30 kg construction of this module compromise its long-term reliability?
A3: No. At roughly 0.30 kg, its specialized compact frame is optimized to save chassis balance while providing rugged structural components that comply with high-voltage industrial insulation profiles, fully meeting standard ControlLogix ratings for mechanical shock and vibrations.
Specifiche aggiuntive
Scalare (V/f)
Vettore
Alimentato a corrente alternata
Guida all'acquisto
- Conferma il modello esatto, il numero di parte e le specifiche prima di ordinare.
- Verifica la compatibilità con la tua macchina o i sistemi di controllo attuali.
- Contatta sale@etowonauto.com o +8617859788089 per assistenza tecnica.
- Esamina le opzioni di consegna, i tempi di attesa e i requisiti di spedizione.
- Segui le istruzioni del produttore e le migliori pratiche durante l’installazione.
Spedizione e Resi
Gli articoli disponibili in magazzino vengono solitamente spediti lo stesso giorno lavorativo. Per i prodotti non attualmente disponibili, i tempi di spedizione possono variare in base alla disponibilità. La spedizione internazionale è disponibile e i costi di spedizione sono calcolati in base alla destinazione, al peso e al corriere scelto.
Le restituzioni sono accettate entro 30 giorni dal ricevimento, a condizione che gli articoli siano inutilizzati e nelle condizioni originali. Le spese di spedizione per la restituzione sono a carico del cliente. Si prega di contattarci prima di restituire qualsiasi articolo per ricevere l'autorizzazione al reso.
Per maggiori dettagli, si prega di consultare la nostra Politica di Spedizione e Reso.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Spedizione Veloce
Ricambi originali per automazione industriale disponibili per spedizione rapida in tutto il mondo.
-
Resi Facili
Supporto per resi entro 30 giorni con garanzia di 12 mesi per una protezione post-vendita affidabile.
-
Supporto 24/7
Supporto professionale reattivo per aiutare a mantenere operazioni stabili ed efficienti.
-
Autentico e Originale
100% autentico, proveniente direttamente da produttori affidabili di automazione industriale.
Guida tecnica e all'acquisto
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...
-
Can Integrated PLC-DCS-TSI Fix Data Silos?
Most industrial digital twins remain static visualization tools because discrete control, process automation, and con...
-
How to Cut Power Plant Outages with ABB and GE Fanuc Retrofits?
This technical article outlines a data-driven approach to modernizing power plant control systems using a hybrid ABB ...