Transformez votre maison avec les dernières solutions multi-électroniques, de l’éclairage intelligent aux appareils commandés par la voix, tous conçus pour rendre la vie plus facile, plus sûre et plus connectée. Optimisez vos opérations avec le système de surveillance Bently Nevada 3500, offrant une surveillance en temps réel des vibrations et de l’état des machines pour prévenir les pannes et maximiser le temps de fonctionnement.
SKU:TSXCTY2C
Schneider TSXCTY2C Modicon Counter Module 2 Channel
Manufacturer: Schneider
Product No.: TSXCTY2C
Product Type: Counter Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Partager
- Livraison rapide
- Assistance 24h/24 et 7j/7
- Assurance qualité
Description
Schneider Electric TSXCTY2C Modicon Counter Module
Schneider Electric TSXCTY2C | Measurement and counter module for the Modicon Premium and TSX Micro automation platforms. Provides 2 counter channels supporting incremental encoders, absolute encoders, and 2/3-wire proximity sensors. Counting frequency up to 1 MHz. Current sink auxiliary inputs for preset, enable, and read functions. Weight: 0.34 kg (0.75 lb).
Key Features
2 counter channels. Counting frequency up to 1 MHz. Incremental encoder frequency 500 kHz (x1) and 250 kHz (x4). 1 ms cycle time. Current sink auxiliary inputs (preset, enable, read). Compatible with 2/3-wire PNP/NPN proximity sensors, incremental encoders (10-30V totem pole, 5V DC RS422), SSI absolute encoders, and ABE7CPA11 parallel absolute encoders. 24V DC output with 0.5 A nominal current. Thermal overload and short-circuit protection. Zener diode overvoltage protection. Reverse polarity protection.
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | TSXCTY2C |
| Product Line | TSX Micro PLCs / Modicon Premium |
| Product Type | Measurement and Counter Module |
| Number of Channels | 2 |
| Counting Frequency | 1,000,000 Hz (1 MHz) |
| Incremental Encoder Frequency (x1) | 500 kHz |
| Incremental Encoder Frequency (x4) | 250 kHz |
| Cycle Time | 1 ms |
| Input Logic | Current sink auxiliary input (preset, enable, read) |
| Input Compatibility | 2/3-wire PNP/NPN proximity sensors, incremental encoder (10-30V totem pole, 5V DC RS422), SSI absolute encoder, ABE7CPA11 |
| Input Voltage (Sensors) | 24V, 16 mA |
| Input Voltage (Auxiliary) | 24V, 8 mA |
| Input Voltage (Encoder) | 5V, 18 mA |
| Voltage State 1 (Sensors/Aux) | ≥ 11V |
| Voltage State 1 (Encoder) | ≥ 2.4V |
| Voltage State 0 (Encoder) | ≤ 1.2V |
| Voltage State 0 (Sensors/Aux) | ≤ 5V |
| Input Impedance (Encoder) | > 270 Ω at 2.4V; 400 Ω at Un |
| Input Impedance (Sensors) | 1500 Ω at Un |
| Input Impedance (Auxiliary) | 3400 Ω at Un |
| Response Time (Loss of 24V) | < 2.5 ms |
| Response Time (Return of 24V) | < 10 ms |
| Output Voltage | 24V DC (19-30V limits) |
| Nominal Output Current | 0.5 A |
| Maximum Voltage Drop | < 0.5V at state 1 |
| Maximum Leakage Current | 0.1 mA |
| Switching Time | < 0.250 ms |
| Output Protection | Thermal overload, short-circuit, Zener overvoltage, reverse polarity |
| Power Dissipation | 7-10 W |
| Current Consumption | 15 mA @ 24V DC; 850 mA @ 5V DC |
| Local Signaling | RUN (green), I/O fault (red), ERR (red), 2x CH diagnostics (green) |
| Electrical Connection | 1 HE-10 20-pin connector; 2 SUB-D 15 connectors |
| Net Weight | 0.34 kg (0.75 lb) |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 5-95% (non-condensing) |
| Operating Altitude | ≤ 2000 m |
| Protective Treatment | TC |
| Country of Origin | France |
Installation Notes
Mount in Modicon Premium or TSX Micro PLC rack. Connect sensors and encoders via HE-10 20-pin and SUB-D 15 connectors. Verify input voltage limits for each device type: ≤5.5V for encoder, 19-30V for sensors and auxiliary inputs. Use shielded cable for encoder signals to maintain signal integrity at high counting frequencies. Maintain IP20 enclosure and pollution degree 2 environment. LED indicators aid commissioning and fault diagnosis.
Engineering Advantages
1 MHz counting frequency supports high-speed position and motion applications. Dual channels enable simultaneous measurement of two axes. Wide input compatibility covers proximity sensors, incremental encoders, and SSI absolute encoders in a single module. Integrated thermal overload, short-circuit, overvoltage, and reverse polarity protection safeguard the module. 1 ms cycle time ensures fast response for time-critical control. LED diagnostics simplify troubleshooting.
FAQs
Q1: What is the maximum counting frequency?
A1: 1 MHz, with 500 kHz (x1) and 250 kHz (x4) for incremental encoders.
Q2: What input types are supported?
A2: 2/3-wire PNP/NPN proximity sensors, incremental encoders (10-30V totem pole, 5V DC RS422), SSI absolute encoders, and ABE7CPA11 parallel absolute encoders.
Q3: What output does the module provide?
A3: 24V DC output with 0.5 A nominal current, supporting positive logic DC inputs up to 15 kΩ.
Spécifications supplémentaires
- Gris
- Argent
Scalaire (V/f)
Vecteur
Alimenté par courant alternatif
Guide d'achat
- Confirmez le modèle exact, le numéro de pièce et les spécifications avant de commander.
- Assurez-vous de la compatibilité avec votre machine ou vos systèmes de contrôle actuels.
- Contactez-nous via sale@etowonauto.com ou au +8617859788089 pour une assistance technique.
- Examinez les options de livraison, les délais et les exigences d’expédition.
- Suivez les instructions du fabricant et les bonnes pratiques lors de l’installation.
Expédition et retour
Les articles en stock sont généralement expédiés le jour même. Pour les produits actuellement en rupture de stock, les délais d'expédition peuvent varier en fonction de la disponibilité. La livraison internationale est disponible, et les frais de port sont calculés selon la destination, le poids et le transporteur choisi.
Les retours sont acceptés dans un délai de 30 jours après réception, à condition que les articles soient inutilisés et en état d'origine. Les frais de retour sont à la charge du client. Veuillez nous contacter avant de retourner un article afin d'obtenir une autorisation de retour.
Pour plus de détails, veuillez consulter notre Politique d'expédition et de retour.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Livraison rapide
Pièces d'automatisation industrielle d'origine disponibles pour expédition rapide dans le monde entier.
-
Retours Faciles
Support de retour sous 30 jours avec une garantie de 12 mois pour une protection après-vente fiable.
-
Assistance 24h/24 et 7j/7
Support professionnel réactif pour aider à maintenir des opérations stables et efficaces.
-
Authentique & Original
100 % authentique, provenant directement de fabricants fiables d'automatisation industrielle.
Guide technique et d'achat
-
Can You Restore a DCS Controller Without Downtime?
This article explains field-proven backup and recovery workflows for ABB AC800M DCS controllers. It covers pre-backup...
-
What Makes Live Honeywell Transmitter Replacement Safe?
This article explains how industrial automation teams can replace aging Honeywell transmitters online without a full ...
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...