Transformez votre maison avec les dernières solutions multi-électroniques, de l’éclairage intelligent aux appareils commandés par la voix, tous conçus pour rendre la vie plus facile, plus sûre et plus connectée. Optimisez vos opérations avec le système de surveillance Bently Nevada 3500, offrant une surveillance en temps réel des vibrations et de l’état des machines pour prévenir les pannes et maximiser le temps de fonctionnement.
SKU:IC693CBL304
IC693CBL304 GE Series 90-30 PCM300 Splitter Cable 1ft
Manufacturer: General Electric
Product No.: IC693CBL304
Product Type: Expansion Cable
Product Origin: USA
Payment:T/T, Western Union
Weight: 140g
Shipping port: Xiamen
Warranty: 12 months
Partager
- Livraison rapide
- Assistance 24h/24 et 7j/7
- Assurance qualité
Description
Product Overview
The GE Fanuc IC693CBL304 is a specialized, highly compact 1-foot (0.3-meter) port expansion "Wye" cable engineered exclusively for the Series 90-30 Programmable Coprocessor Module (IC693PCM300). This ultra-lightweight adapter, weighing only 0.14 kg (0.31 lbs), serves as a signal splitter, separating combined RS-232 and RS-485 communications from a single physical port on the PCM host module into two distinct, isolated connections. Equipped with a space-saving right-angle male connector on the module side and dual-female connectors on the output end, it delivers seamless signal routing without adding physical strain or bulky weight to your PLC rack assembly.
Key Advantages
- Dual-Protocol Separation: Effortlessly splits combined lines to deliver dedicated RS-232 signals on one leg and RS-485 signals on the other, allowing simultaneous dual-port operation.
- Right-Angle & Compact Design: The module-end connector features a right-angle profile, and at a minimal weight of just 0.14 kg, it fits neatly into tight control panels and shallow enclosures without straining delicate ports.
- Continuous Shielding: Encased in high-quality, continuous electrical shielding to block electromagnetic interference (EMI) and preserve communication speeds in noisy industrial environments.
- 90/70 to 90/30 Compatibility: Standardizes physical connections, making the Series 90/70 PCM interface fully compatible with Series 90/30 PCM module hardware.
Technical Specifications
| Model Number | IC693CBL304 |
| Brand / Series | GE Fanuc / Series 90-30 |
| Cable Type | Port Expansion (Wye / Splitter) Cable |
| Module Compatibility | IC693PCM300 (Programmable Coprocessor Module) |
| Cable Length | 1 foot (approx. 30 cm) |
| Connector 1 (Module End) | Right-Angle Male Connector |
| Connector 2 (Device End) | Dual-Female Connectors (Port 1 and Port 2) |
| Shielding Type | Continuous high-coverage shield |
| Net Weight | 0.14 kg (0.31 lbs) |
| Max Units Per Module | One Wye cable per PCM module |
| Lifecycle Status | Discontinued / Obsolete (Available as legacy support) |
Quick Installation & Safety Tips
- Equal Potential Grounding: Ensure that the IC693CBL304 cable shielding, the host PCM module, and the PLC baseplate are all tied to the same electrical ground potential. Caution: Ground loops or mismatched voltage potentials can permanently damage connected programming terminals or internal module electronics.
- Align Right-Angle Connector Carefully: When plugging the right-angle male end into the PCM module, line up the pins smoothly before applying pressure to avoid bending the pins in the module's communication port.
- Port Identification: The dual-female end splits the signals into Port 1 and Port 2. Refer to your system program configuration to ensure the RS-232 serial link and RS-485 serial link are mapped and connected to the correct corresponding output ports.
Technical FAQs
Q1: Why does this cable split into two connections from a single physical port?
A1: The IC693PCM300 module consolidates both RS-232 and RS-485 pinouts into a single high-density connector to save space. The IC693CBL304 Wye cable acts as a hardware splitter, separating these signal lines into two independent physical ports (Port 1 and Port 2) to allow simultaneous connections.
Q2: What happens if the cable and baseplate are not grounded at the same potential?
A2: Failure to ground the system at equal ground potential will lead to stray currents flowing through the communications line. This can cause communication faults, signal corruption, or catastrophic hardware damage to the PCM module, the cable, and connected programmer devices.
Q3: Is the IC693CBL304 cable included when I buy the IC693PCM300 module?
A3: Yes, this Wye cable was originally supplied standard inside the box with the IC693PCM300 module. However, because it can wear out or get lost during field servicing, it is also available as an individual replacement accessory.
Spécifications supplémentaires
Scalaire (V/f)
Vecteur
Alimenté par courant alternatif
Guide d'achat
- Confirmez le modèle exact, le numéro de pièce et les spécifications avant de commander.
- Assurez-vous de la compatibilité avec votre machine ou vos systèmes de contrôle actuels.
- Contactez-nous via sale@etowonauto.com ou au +8617859788089 pour une assistance technique.
- Examinez les options de livraison, les délais et les exigences d’expédition.
- Suivez les instructions du fabricant et les bonnes pratiques lors de l’installation.
Expédition et retour
Les articles en stock sont généralement expédiés le jour même. Pour les produits actuellement en rupture de stock, les délais d'expédition peuvent varier en fonction de la disponibilité. La livraison internationale est disponible, et les frais de port sont calculés selon la destination, le poids et le transporteur choisi.
Les retours sont acceptés dans un délai de 30 jours après réception, à condition que les articles soient inutilisés et en état d'origine. Les frais de retour sont à la charge du client. Veuillez nous contacter avant de retourner un article afin d'obtenir une autorisation de retour.
Pour plus de détails, veuillez consulter notre Politique d'expédition et de retour.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Livraison rapide
Pièces d'automatisation industrielle d'origine disponibles pour expédition rapide dans le monde entier.
-
Retours Faciles
Support de retour sous 30 jours avec une garantie de 12 mois pour une protection après-vente fiable.
-
Assistance 24h/24 et 7j/7
Support professionnel réactif pour aider à maintenir des opérations stables et efficaces.
-
Authentique & Original
100 % authentique, provenant directement de fabricants fiables d'automatisation industrielle.
Guide technique et d'achat
-
Hybrid DCS/PLC: Digital Twin Fix?
This technical article examines how hybrid ABB DCS and Allen‑Bradley PLC architectures overcome data isolation and co...
-
Why Do 68% of Turbine False Trips Come from TSI-DCS Signal Mismatch
This technical article examines the critical compatibility challenges between Bently Nevada 3300/3500 TSI probes and ...
-
Cutting Multi-Vendor Downtime by 32% – Is Your Plant Ready?
Emerson Boundless Automation unifies data from ABB DCS, Allen-Bradley PLC, and GE Fanuc controllers without gateways....
-
Can Hybrid PLC-TSI Replace Expensive DCS Systems?
Small and medium refineries face critical monitoring bottlenecks with manual inspections causing 8-hour fault detecti...
-
What is the Real Cost of Corrosion on Factory Automation?
Standard automation hardware fails rapidly in corrosive heavy industries, causing significant downtime and mainten...
-
Can DCS-PLC-TSI Synergy Cut Refinery Furnace Energy Loss by 7%?
This article explains how synchronizing Distributed Control Systems, Programmable Logic Controllers, and Turbine Supe...
