Transformez votre maison avec les dernières solutions multi-électroniques, de l’éclairage intelligent aux appareils commandés par la voix, tous conçus pour rendre la vie plus facile, plus sûre et plus connectée. Optimisez vos opérations avec le système de surveillance Bently Nevada 3500, offrant une surveillance en temps réel des vibrations et de l’état des machines pour prévenir les pannes et maximiser le temps de fonctionnement.
SKU:IC670MDL930
IC670MDL930 GE Fanuc Field Control 8 Point Relay Module
Manufacturer: General Electric
Product No.: IC670MDL930
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Partager
- Livraison rapide
- Assistance 24h/24 et 7j/7
- Assurance qualité
Description
Product Overview
The GE Fanuc IC670MDL930 is an 8-point individually isolated discrete relay output module belonging to the Field Control I/O system. Engineered for high-density, reliable switching in industrial automation and process control architectures, this module provides flexible AC/DC load driving for field devices such as solenoids, motor starters, indicator lights, and actuators.
Featuring a total of eight channels organized into six (6) Form A (Normally Open) contacts and two (2) Form C (SPDT / Normally Open & Normally Closed) contacts, the IC670MDL930 delivers channel-to-channel isolation with built-in RC snubber transient protection (R=47.5 Ω, C=0.022 µF). With a compact design weighing approximately 0.30 kg (0.66 lbs), it operable across 5–30 V DC, 31–125 V DC, and 5–265 V AC, supporting up to 2.0 A continuous load per channel (16 A maximum per module) while drawing a maximum of 313 mA from the Bus Interface Unit (BIU) logic supply.
Core Technical Advantages
- Individual Channel Isolation: Each output contact is independently isolated (250 VAC continuous, 1500 VAC for 1 min), preventing ground loops and protecting logic-side electronics.
- Mixed Contact Configuration: Integrates six Form A (N.O.) and two Form C (N.O./N.C.) silver-alloy contacts for versatile logic and safety circuit wiring.
- Integrated RC Snubber Suppression: Built-in snubber networks across contacts mitigate high-frequency voltage spikes caused by inductive load switching without external components.
- Comprehensive Diagnostic LEDs: Features channel-level status LEDs alongside power indicators to simplify field troubleshooting and signal verification.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | GE Fanuc |
| Catalog Part Number | IC670MDL930 |
| Product Family | Field Control I/O System |
| Module Type | Isolated Discrete Relay Output Module |
| Number of Channels | 8 channels (Individual channel isolation) |
| Contact Forms | 6 × Form A (N.O.) / 2 × Form C (N.O. & N.C.) |
| Nominal Operating Voltages | 5 / 24 / 125 V DC; 120 / 240 V AC (47–63 Hz) |
| Operating Voltage Ranges | 0 to 130 V DC / 0 to 265 V AC |
| Maximum Load Current (AC) | 2.0 A per point (5 to 265 V AC) |
| Maximum Load Current (DC) | 2.0 A per point (5 to 30 V DC); 0.2 A per point (31 to 125 V DC) |
| Total Module Current Capacity | 16 A maximum (resistive load) |
| Minimum Load Current | 10 mA per point |
| Maximum Inrush Current | 5 A for 20 ms |
| BIU Current Consumption | 313 mA maximum from BIU logic supply |
| Relay Technology & Material | Fixed coil, moving armature; Silver Alloy contacts (0.2 Ω resistance) |
| On / Off Response Time | 10 ms maximum transition time |
| Maximum Switching Frequency | 20 cycles/minute (inductive loads) |
| Contact Life Expectancy | Mechanical: 20 × 10⁶ ops; Electrical: 10⁵ ops at rated resistive load |
| Internal Protection & Fusing | RC Snubber (R=47.5 Ω, C=0.022 µF); No internal fuse |
| Isolation Voltage | 250 VAC continuous / 1500 VAC for 1 min (Input to Logic / Group to Group) |
| Shipping Weight | Approx. 0.30 kg (0.66 lbs) |
Installation & Wiring Guidelines
- Field Base Mounting: Snap the IC670MDL930 module onto the matching Field Control terminal base, ensuring backplane connectors seal firmly to enable BIU power and data flow.
- External Power Distribution: Connect an external AC or DC field power source to drive loads connected through relay contacts. Ensure proper external fusing since the module does not contain internal fuses.
- Inductive Load Protection: While built-in RC snubbers suppress standard noise transients, high-inductance DC loads should utilize secondary flyback diodes installed directly across the load terminals.
Technical FAQs
Q1: What are the current rating limits for DC loads on the GE Fanuc IC670MDL930?
A1: Each contact supports 2.0 A for low-voltage DC (5 to 30 V DC), but drops to 0.2 A max for high-voltage DC applications (31 to 125 V DC).
Q2: Does the IC670MDL930 module provide individual channel isolation?
A2: Yes, all 8 channels are individually isolated up to 250 VAC continuous (1500 VAC for 1 minute) between groups, logic, and frame ground.
Q3: What power does the module draw from the Field Control BIU backplane?
A3: The module draws up to 313 mA from the Bus Interface Unit (BIU) power supply to energize the relay coils.
Spécifications supplémentaires
Scalaire (V/f)
Vecteur
Alimenté par courant alternatif
Guide d'achat
- Confirmez le modèle exact, le numéro de pièce et les spécifications avant de commander.
- Assurez-vous de la compatibilité avec votre machine ou vos systèmes de contrôle actuels.
- Contactez-nous via sale@etowonauto.com ou au +8617859788089 pour une assistance technique.
- Examinez les options de livraison, les délais et les exigences d’expédition.
- Suivez les instructions du fabricant et les bonnes pratiques lors de l’installation.
Expédition et retour
Les articles en stock sont généralement expédiés le jour même. Pour les produits actuellement en rupture de stock, les délais d'expédition peuvent varier en fonction de la disponibilité. La livraison internationale est disponible, et les frais de port sont calculés selon la destination, le poids et le transporteur choisi.
Les retours sont acceptés dans un délai de 30 jours après réception, à condition que les articles soient inutilisés et en état d'origine. Les frais de retour sont à la charge du client. Veuillez nous contacter avant de retourner un article afin d'obtenir une autorisation de retour.
Pour plus de détails, veuillez consulter notre Politique d'expédition et de retour.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Livraison rapide
Pièces d'automatisation industrielle d'origine disponibles pour expédition rapide dans le monde entier.
-
Retours Faciles
Support de retour sous 30 jours avec une garantie de 12 mois pour une protection après-vente fiable.
-
Assistance 24h/24 et 7j/7
Support professionnel réactif pour aider à maintenir des opérations stables et efficaces.
-
Authentique & Original
100 % authentique, provenant directement de fabricants fiables d'automatisation industrielle.
Guide technique et d'achat
-
Does New GE Fanuc 90-30 Backplane Stabilize Cement Kilns?
This technical article examines how brand-new GE Fanuc 90-30 PLC backplane components deliver measurable reliability ...
-
Why 28% of Gas Turbine Trips Stem from Monitoring Failures?
Combined cycle gas turbines demand micron-level shaft monitoring to prevent vibration resonance and unplanned outages...
-
Can ABB AC500 redundant power eliminate mill downtime?
This technical article examines how ABB AC500 redundant power modules resolve unplanned downtime caused by voltage...
-
Is Your Wastewater Plant Ready for a Data-Driven Upgrade?
This technical article examines the operational bottlenecks of legacy wastewater treatment automation and presents a ...
-
Can Eddy-Current Probes Prevent LNG Compressor Shutdowns?
This technical article examines how Bently Nevada eddy-current proximity probes provide high-precision vibration...
-
Can SIL 3 PLCs Really Slash $1M in Annual Offshore Maintenance?
This technical article examines how Allen‑Bradley GuardPLC SIL 3 safety controllers reduce unplanned offshore downtim...