Transformez votre maison avec les dernières solutions multi-électroniques, de l’éclairage intelligent aux appareils commandés par la voix, tous conçus pour rendre la vie plus facile, plus sûre et plus connectée. Optimisez vos opérations avec le système de surveillance Bently Nevada 3500, offrant une surveillance en temps réel des vibrations et de l’état des machines pour prévenir les pannes et maximiser le temps de fonctionnement.
SKU:CI920AN
ABB 3BDH000692R1 CI920AN Advant 800xA Communication Interface
Manufacturer: ABB
Product No.: CI920AN
Product Type: I/O Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 130g
Shipping port: Xiamen
Warranty: 12 months
Partager
- Livraison rapide
- Assistance 24h/24 et 7j/7
- Assurance qualité
Description
Core Technical Advantages
Seamless HART Field Device Pass-Through
The CI920AN natively supports HART protocol bridging over the PROFIBUS DP network configuration. This allows maintenance engineering teams to perform asset management operations, calibrate remote transmitters, change process parameters, and view advanced health metrics directly from the central control room without running dedicated secondary instrumentation wires.
Advanced System and Network Redundancy
To maximize uptime in critical continuous-process environments, the CI920AN supports full master/slave line redundancy. If a primary master module failure or a network cable break is detected, the redundant standby configuration takes over the communication bus instantaneously, ensuring zero data drops or unexpected automated plant shutdowns.
Rugged S900 Modular Architecture
Part of the rugged S900 system platform, the CI920AN features an extremely small physical footprint (20mm thickness), optimizing DIN rail real estate inside control marshaling panels. Its energy-efficient internal circuitry generates minimal thermal load, contributing to its broad ambient operating spectrum and long-term lifespan.
Technical Specifications
| Parameter Code | Specification Details |
|---|---|
| Brand / Manufacturer | ABB Automation |
| Catalog Part Number | 3BDH000692R1 |
| Model Identification | CI920AN (Non-IS Version) |
| Signal / Module Type | PROFIBUS DP Remote I/O Communication Interface |
| HART Protocol Compatibility | Yes (Supports cyclic and acyclic HART parameter routing) |
| Redundancy Support | Yes (Supports dual redundant network line topologies) |
| Mechanical Classification | S900 Sub-rack Mountable Module |
| Dimensions (W x D x H) | 20 x 104 x 104 mm (0.79 x 4.09 x 4.09 inches) |
| Operating Temperature Range | -20°C to 60°C (-4°F to 140°F) |
| Environmental Compliance | CE Marked, RoHS Directive 2011/65/EU, WEEE Small Equipment |
Installation and Maintenance
S900 Slot Mounting and Hot-Swap Guidelines
The CI920AN is engineered to snap directly into the designated communication slots on an S900 terminal unit or backplane chassis. To install, align the rear connector pin layout with the sub-rack guide tracking channels and press firmly until the locking tabs snap into place. The module supports live-insertion/hot-swapping configurations, allowing maintenance teams to change components without interrupting power to the remaining active I/O rack segments.
Redundant Bus Line Termination and Configuration
When implementing redundant topologies, install dual CI920AN modules into the corresponding primary and secondary sub-rack slots. Ensure the interconnecting PROFIBUS DP cables are terminated using high-quality network plugs with integrated terminating resistors active on both ends of the segment to avoid signal reflections and data communication corruption.
Climatic Control and Environmental Preservation
The module is certified to perform across a broad temperature scale (-20°C to 60°C) and withstand non-condensing relative humidity levels up to 93% (±3% at 40°C). For outdoor marshaling applications or environments high in ambient particulate count, house the S900 system sub-rack assembly within a sealed, climate-controlled cabinet matching IP65 or NEMA 4 standards.
Engineering Advantages
Direct System 800xA Optimization
By routing field information through standard PROFIBUS DP layers, the CI920AN offers smooth integration with ABB’s core asset optimization software utilities. This integration maps process inputs, diagnostic registers, and status alerts directly into the operator workstation environment without requiring complex ladder logic rewriting.
Reduced Engineering and Wiring Overhead
Combining many analog and digital I/O clusters onto a single serial communication line reduces the total volume of field cables running back to the main control station. This distributed I/O framework simplifies project engineering, lowers installation costs, and reduces the time required for system commissioning.
Comprehensive Compliance Standards
Complying with strict European CE mandates, RoHS Directive 2011/65/EU, and falling into the WEEE Small Equipment category (external dimensions ≤ 50cm), this module meets environmental and electronic safety standards required for global infrastructure, power generation, and manufacturing applications.
Technical FAQs
Q1: Can the CI920AN 3BDH000692R1 be installed directly in ATEX Zone 1 hazardous explosive zones?
A1: No. While the S900 family contains modules specifically engineered for intrinsically safe field areas, the CI920AN (Model Code ending with 'N') is classified as a non-intrinsically safe interface module. It should be mounted inside a safe area or within a flame-proof / purged enclosure when used in hazardous industrial settings.
Q2: How does the CI920AN handle a sudden failure of the primary PROFIBUS line?
A2: When deployed in a redundant configuration with a secondary backup module, both units monitor network status in real time. If the active communication channel fails or experiences a broken cable, the internal firmware switches to the redundant link within milliseconds, ensuring uninterrupted control loop data tracking.
Q3: Does this module require specialized software toolsets for initial node address assignment?
A3: Initial node station addresses can typically be configured using standard hardware configuration switches located on the module/backplane housing, or established via PROFIBUS network master configuration software utilities during system integration.
Spécifications supplémentaires
Scalaire (V/f)
Vecteur
Alimenté par courant alternatif
Guide d'achat
- Confirmez le modèle exact, le numéro de pièce et les spécifications avant de commander.
- Assurez-vous de la compatibilité avec votre machine ou vos systèmes de contrôle actuels.
- Contactez-nous via sale@etowonauto.com ou au +8617859788089 pour une assistance technique.
- Examinez les options de livraison, les délais et les exigences d’expédition.
- Suivez les instructions du fabricant et les bonnes pratiques lors de l’installation.
Expédition et retour
Les articles en stock sont généralement expédiés le jour même. Pour les produits actuellement en rupture de stock, les délais d'expédition peuvent varier en fonction de la disponibilité. La livraison internationale est disponible, et les frais de port sont calculés selon la destination, le poids et le transporteur choisi.
Les retours sont acceptés dans un délai de 30 jours après réception, à condition que les articles soient inutilisés et en état d'origine. Les frais de retour sont à la charge du client. Veuillez nous contacter avant de retourner un article afin d'obtenir une autorisation de retour.
Pour plus de détails, veuillez consulter notre Politique d'expédition et de retour.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Livraison rapide
Pièces d'automatisation industrielle d'origine disponibles pour expédition rapide dans le monde entier.
-
Retours Faciles
Support de retour sous 30 jours avec une garantie de 12 mois pour une protection après-vente fiable.
-
Assistance 24h/24 et 7j/7
Support professionnel réactif pour aider à maintenir des opérations stables et efficaces.
-
Authentique & Original
100 % authentique, provenant directement de fabricants fiables d'automatisation industrielle.
Guide technique et d'achat
-
Can DeltaV Redundant DCS Eliminate Oil & Gas Shutdowns?
This article examines Emerson DeltaV DCS redundant architecture for oil and gas, presenting outage cost data, 1:1 red...
-
Why Are Legacy PLCs the Biggest Risk in New Energy Smart Factories?
This technical article examines how Allen‑Bradley Safety PLC resolves the safety-efficiency paradox in lithium batter...
-
Can Bently Nevada + GE Fanuc PLC Prevent Mill Shutdowns?
This article examines Bently Nevada sensors integrated with GE Fanuc PLC for predictive maintenance in metallurgy. 20...
-
What Is the Data-Driven Strategy for Guaranteeing Genuine Control Spares?
Fragmented spare parts procurement causes 68% of unplanned plant shutdowns and inflates costs by 22% annually. This e...
-
Can GE Fanuc-Emerson Integration Cut OPEX 18%?
A regional refinery cut downtime 28% and energy use 18% via GE Fanuc PLC-Emerson DCS integration. Retained legacy har...
-
Why Do 78% of Digital Retrofits Fail Without Edge Data?
This technical article examines how Emerson's industrial edge gateway resolves multi-vendor OT interoperability chall...
