Direkt zum Inhalt
Automatisierungsteile, weltweite Lieferung
Zu Produktinformationen springen
1 von 3

SKU:6ES7455-0VS00-0AE0

Siemens 6ES7455-0VS00-0AE0 | S7-400 FM 455 C 16 AI/16 AO

Auf Lager (23 Einheiten), versandbereit
  • Manufacturer: Siemens

  • Product No.: 6ES7455-0VS00-0AE0

  • Product Type: Control Module

  • Product Origin: DE

  • Payment:T/T, Western Union

  • Weight: 1400g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-Tage-Rückgaberecht · 12 Monate Garantie
  • Schnelle Lieferung
  • Rund-um-die-Uhr Unterstützung
  • Qualitätssicherung

Beschreibung

Product Overview

The Siemens 6ES7455-0VS00-0AE0 is an FM 455 C control module for SIMATIC S7-400 systems, providing 16 continuous control channels. It combines 16 analog inputs, 16 digital inputs, and 16 analog outputs in a single module. Weighing approximately 1,400 g, this controller supports thermocouples, Pt100 resistance thermometers, and standard voltage/current signals for comprehensive process control.

Technical Configuration

This module operates from 24 V DC load voltage with a permissible range of 20.4 to 28.8 V. It draws a maximum of 440 mA (typical 370 mA) from load voltage without load. The 16 analog inputs accept thermocouples or 2-wire connections, while 8 channels support Pt100 or 4-wire connections. Integrated control technology provides 16 closed-loop controllers. Potential separation between channels and backplane bus uses optocouplers, tested at 500 V DC isolation.

Technical Specifications

Parameter Value
Manufacturer Siemens
Part Number 6ES7455-0VS00-0AE0
Product Type FM 455 C Control Module
Series SIMATIC S7-400
Control Channels 16 continuous
Load Voltage 24 V DC (20.4-28.8 V)
Current from L+ (No Load) Max 440 mA, typ. 370 mA
Power Loss Typ. 12 W, max 17.3 W
Digital Inputs 16, 24 V DC (IEC 61131 type 2)
DI Signal "0" / "1" -3 to +5 V / 13 to 30 V (7 mA typical)
Analog Inputs 16 (8 with Pt100/4-wire)
Voltage Input Ranges 0 to +10 V, -1.75 to +11.75 V, -80 to +80 mV
Current Input Ranges 0-20 mA, 0-23.5 mA, -3.5 to +23.5 mA, 4-20 mA
Thermocouple Types B, J, K, R, S
RTD Type Pt100
Analog Outputs 16
Voltage Output Ranges 0-10 V, -10 to +10 V
Current Output Ranges 0-20 mA, -20 to +20 mA, 4-20 mA
Voltage Output Load Min 1 kΩ, max 1 µF capacitive
Current Output Load Max 500 Ω, max 1 mH inductive
Resolution 12 or 14 bit, parameterizable
Settling Time 0.1 ms resistive, 3.3 ms capacitive, 0.5 ms inductive
Closed-Loop Controllers 16
Isolation Tested 500 V DC
Dimensions (W x H x D) 50 x 290 x 210 mm
Weight Approx. 1,400 g
Front Connector 2 x 48-pin required

Installation Guide

Install the FM 455 C module in a compatible S7-400 rack slot and secure both 48-pin front connectors. Connect 24 V DC load voltage within the 20.4-28.8 V range. Use shielded cable for analog signals with maximum 200 m length (50 m for 80 mV and thermocouple inputs). Verify voltage output loads meet minimum 1 kΩ and current output loads remain below 500 Ω. Internal or external Pt100 temperature compensation is parameterizable for thermocouple measurements.

Engineering Advantages

This module integrates 16 closed-loop controllers with 16 AI, 16 DI, and 16 AO in a single unit, reducing rack space and wiring. Support for thermocouples, Pt100 RTDs, and standard voltage/current signals provides exceptional measurement flexibility. Parameterizable 12-bit or 14-bit resolution suits both standard and high-precision applications. Optocoupler isolation between channels and backplane bus protects the system from field transients. Short-circuit-protected voltage outputs with 25 mA limit safeguard connected actuators.

Technical FAQs

Q1: How many control loops does the 6ES7455-0VS00-0AE0 support?
A1: This module integrates 16 closed-loop controllers with 16 analog inputs, 16 digital inputs, and 16 analog outputs.

Q2: What temperature sensor types does this module accept?
A2: It accepts thermocouple types B, J, K, R, and S, plus Pt100 resistance thermometers with parameterizable internal or external compensation.

Q3: What are the analog output load requirements?
A3: Voltage outputs require minimum 1 kΩ load (max 1 µF capacitive), while current outputs accept maximum 500 Ω load (max 1 mH inductive).

🏷️ Tags: Control Module Siemens

Skalar (V/f)

Vektor

Netzbetrieben

  • Bestätigen Sie vor der Bestellung das genaue Modell, die Teilenummer und die Spezifikationen.
  • Stellen Sie die Kompatibilität mit Ihrer aktuellen Maschine oder Steuerung sicher.
  • Kontaktieren Sie uns für technische Unterstützung unter sale@etowonauto.com oder +8617859788089.
  • Überprüfen Sie Lieferoptionen, Lieferzeiten und Versandanforderungen.
  • Folgen Sie bei der Installation den Herstelleranweisungen und bewährten Verfahren.

Vorrätige Artikel werden in der Regel noch am selben Werktag versandt. Bei Produkten, die derzeit nicht auf Lager sind, können die Versandzeiten je nach Verfügbarkeit variieren. Internationaler Versand ist möglich, und die Versandkosten werden basierend auf Zielort, Gewicht und gewähltem Versanddienstleister berechnet.

Rücksendungen werden innerhalb von 30 Tagen nach Erhalt akzeptiert, vorausgesetzt, die Artikel sind unbenutzt und im Originalzustand. Die Rücksendekosten trägt der Kunde. Bitte kontaktieren Sie uns vor der Rücksendung eines Artikels, um eine Rücksendegenehmigung zu erhalten.

Für weitere Details lesen Sie bitte unsere Versand- & Rückgaberichtlinie.

Vollständige Details anzeigen

SICHERN SIE ZUVERLÄSSIGE MASCHINENLEISTUNG

Verwandeln Sie Ihr Zuhause mit den neuesten Multi-Elektronik-Lösungen, von intelligenter Beleuchtung bis hin zu sprachgesteuerten Geräten – alle darauf ausgelegt, das Leben einfacher, sicherer und vernetzter zu machen. Optimieren Sie Ihre Abläufe mit dem Bently Nevada 3500 Überwachungssystem, das eine Echtzeit-Überwachung von Vibrationen und Maschinenzuständen bietet, um Ausfälle zu verhindern und die Betriebszeit zu maximieren.