Mô tả

Pepperl+Fuchs KCD2-SOT-Ex1.LB Switch Amplifier

The Pepperl+Fuchs KCD2-SOT-Ex1.LB is an isolated switch amplifier for hazardous areas. This 1-channel barrier interfaces NAMUR sensors with control systems. It provides two transistor outputs for signal splitting applications. The Pepperl+Fuchs KCD2-SOT-Ex1.LB offers safe operation in explosive atmospheres with ATEX certification.

Product Identification

  • Manufacturer: Pepperl+Fuchs
  • Model Number: KCD2-SOT-Ex1.LB switch amplifier
  • Product Type: 1-Channel Isolated Barrier
  • Primary Function: Digital input signal conditioning
  • Safety Rating: SIL 2, SC 3 per IEC/EN 61508
  • Certification: ATEX certified for hazardous areas
  • Housing Width: 12.5 mm compact design

Power Supply Specifications

  • Supply Voltage: 24 V DC nominal (19-30 V DC range)
  • Connection: Power Rail or terminals 9+, 10-
  • Rated Current: 20-15 mA typical consumption
  • Power Dissipation: ≤ 700 mW maximum
  • Ripple Tolerance: ≤ 10 % input ripple

Input Specifications

  • Signal Type: Digital Input (NAMUR or dry contact)
  • Connection: Terminals 1+, 2- (field side)
  • NAMUR Values: 10 V DC / 8 mA per EN 60947-5-6
  • Switching Point: 1.2-2.1 mA with 0.2 mA hysteresis
  • Line Fault Detection: Breakage I ≤ 0.1 mA, short I ≥ 6.5 mA
  • Pulse Requirements: Min. 100 µs pulse/pause ratio

Output Performance

  • Output Channels: Two passive transistor outputs
  • Connection: Output I: terminals 5,6; Output II: terminals 7,8
  • Rated Voltage: 30 V DC maximum
  • Rated Current: 50 mA per output
  • Response Time: ≤ 200 µs fast switching
  • 1-Signal Level: (External voltage) - 3V max at 50 mA
  • 0-Signal Level: Blocked output (≤10 µA leakage)
  • Switching Frequency: ≤ 5 kHz maximum

Safety & Isolation

  • Safety Level: SIL 2, Systematic Capability SC 3
  • Galvanic Isolation: Reinforced insulation 300 Veff
  • Isolation Ratings: Input/Output: 300 Veff reinforced
  • Hazardous Area: ATEX certified [Ex ia Ga] IIC
  • Protection Degree: IP20 for indoor use

Configuration & Display

  • Configuration: DIP switch settings
  • Display Elements: LED status indicators
  • Labeling: Front space for identification
  • Operating Mode: Reversible operation possible
  • Signal Splitting: 1 input to 2 outputs capability

Environmental Specifications

  • Temperature Range: -20°C to +70°C standard
  • Extended Range: Up to 70°C with derating
  • Mounting: 35 mm DIN rail per EN 60715
  • Dimensions: 12.5 x 119 x 114 mm (WxHxD)
  • Weight: Approx. 100 grams

Certifications & Compliance

  • ATEX Certificate: BASEEFA 13 ATEX 0080
  • Marking: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC
  • EMC Directive: 2014/30/EU, EN 61326-1:2013
  • Safety Standards: IEC 61010-1:2010 compliance

Installation Guidelines

  • Mount on 35 mm DIN rail in appropriate enclosure
  • Connect 24V DC power via Power Rail or terminals
  • Wire NAMUR sensor or dry contact to input terminals
  • Connect outputs to control system inputs
  • Configure DIP switches for required operation mode
  • Verify proper grounding for hazardous area installation

Frequently Asked Questions (FAQ)

What is the main purpose of this switch amplifier?

The Pepperl+Fuchs KCD2-SOT-Ex1.LB safely interfaces hazardous area sensors with control systems.

Can I use this with standard mechanical contacts?

Yes, it accepts both NAMUR sensors and dry contact inputs.

What does "signal splitter" function mean?

It can take one input signal and provide two identical output signals.

How does line fault detection work?

It detects open circuits (<0.1 mA) and short circuits (>6.5 mA) in field wiring.

What hazardous area classifications does it support?

ATEX Zone 0/1 for gas and Zone 20/21 for dust explosive atmospheres.

What configuration options are available?

DIP switches allow setting operating mode, output configuration, and fault behavior.

For technical specifications or to order the KCD2-SOT-Ex1.LB, email sale@etowonauto.com.

Content provided by Etowon Auto.

🏷️ Tags: Switch Amplifier
  • Xanh dương

Vô hướng (V/f)

Vector

Chạy bằng điện xoay chiều

  • Xác nhận chính xác mẫu mã, số bộ phận và thông số kỹ thuật trước khi đặt hàng.
  • Đảm bảo tương thích với máy móc hoặc hệ thống điều khiển hiện tại của bạn.
  • Liên hệ qua sale@etowonauto.com hoặc +8617859788089 để được hỗ trợ kỹ thuật.
  • Xem xét các tùy chọn giao hàng, thời gian giao và yêu cầu vận chuyển.
  • Tuân theo hướng dẫn của nhà sản xuất và các thực hành tốt nhất trong quá trình lắp đặt.

Các mặt hàng có sẵn trong kho thường được gửi đi trong cùng ngày làm việc. Đối với các sản phẩm hiện không có sẵn, thời gian gửi hàng có thể thay đổi tùy theo tình trạng hàng. Vận chuyển quốc tế có sẵn, và chi phí vận chuyển được tính theo điểm đến, trọng lượng và lựa chọn nhà vận chuyển.

Chúng tôi chấp nhận trả hàng trong vòng 30 ngày kể từ khi nhận hàng, với điều kiện sản phẩm chưa sử dụng và còn nguyên trạng ban đầu. Chi phí vận chuyển trả hàng do khách hàng chịu trách nhiệm. Vui lòng liên hệ với chúng tôi trước khi trả bất kỳ mặt hàng nào để nhận được sự chấp thuận trả hàng.

Để biết thêm chi tiết, vui lòng xem lại Chính sách Vận chuyển & Trả hàng.

Xem toàn bộ chi tiết

ĐẢM BẢO HIỆU SUẤT MÁY MÓC ĐÁNG TIN CẬY

Biến đổi ngôi nhà của bạn với các giải pháp đa điện tử mới nhất, từ hệ thống chiếu sáng thông minh đến các thiết bị điều khiển bằng giọng nói, tất cả được thiết kế để làm cho cuộc sống trở nên dễ dàng hơn, an toàn hơn và kết nối hơn.

Tối ưu hóa hoạt động của bạn với Hệ thống Giám sát Bently Nevada 3500, cung cấp giám sát rung động và tình trạng máy móc theo thời gian thực để ngăn ngừa sự cố và tối đa hóa thời gian hoạt động.