Evinizi, akıllı aydınlatmadan ses kontrollü cihazlara kadar hayatı daha kolay, güvenli ve bağlantılı hale getirmek için tasarlanmış en yeni çoklu elektronik çözümlerle dönüştürün. Arızaları önlemek ve çalışma süresini maksimize etmek için gerçek zamanlı titreşim ve makine durumu izleme sunan Bently Nevada 3500 İzleme Sistemi ile operasyonlarınızı optimize edin.
SKU:KCD2-SOT-EX1.LB
KCD2-SOT-Ex1.LB Isolated Barrier | Pepperl+Fuchs
Manufacturer: Pepperl+Fuchs
Product No.: KCD2-SOT-EX1.LB
Product Type: Switch Amplifier
Product Origin: DE
Payment:T/T, Western Union
Weight: 100g
Shipping port: Xiamen
Warranty: 12 months
Paylaş
- Hızlı Teslimat
- 7/24 Destek
- Kalite Güvencesi
Açıklama
Pepperl+Fuchs KCD2-SOT-Ex1.LB Switch Amplifier
The Pepperl+Fuchs KCD2-SOT-Ex1.LB is an isolated switch amplifier for hazardous areas. This 1-channel barrier interfaces NAMUR sensors with control systems. It provides two transistor outputs for signal splitting applications. The Pepperl+Fuchs KCD2-SOT-Ex1.LB offers safe operation in explosive atmospheres with ATEX certification.
Product Identification
- Manufacturer: Pepperl+Fuchs
- Model Number: KCD2-SOT-Ex1.LB switch amplifier
- Product Type: 1-Channel Isolated Barrier
- Primary Function: Digital input signal conditioning
- Safety Rating: SIL 2, SC 3 per IEC/EN 61508
- Certification: ATEX certified for hazardous areas
- Housing Width: 12.5 mm compact design
Power Supply Specifications
- Supply Voltage: 24 V DC nominal (19-30 V DC range)
- Connection: Power Rail or terminals 9+, 10-
- Rated Current: 20-15 mA typical consumption
- Power Dissipation: ≤ 700 mW maximum
- Ripple Tolerance: ≤ 10 % input ripple
Input Specifications
- Signal Type: Digital Input (NAMUR or dry contact)
- Connection: Terminals 1+, 2- (field side)
- NAMUR Values: 10 V DC / 8 mA per EN 60947-5-6
- Switching Point: 1.2-2.1 mA with 0.2 mA hysteresis
- Line Fault Detection: Breakage I ≤ 0.1 mA, short I ≥ 6.5 mA
- Pulse Requirements: Min. 100 µs pulse/pause ratio
Output Performance
- Output Channels: Two passive transistor outputs
- Connection: Output I: terminals 5,6; Output II: terminals 7,8
- Rated Voltage: 30 V DC maximum
- Rated Current: 50 mA per output
- Response Time: ≤ 200 µs fast switching
- 1-Signal Level: (External voltage) - 3V max at 50 mA
- 0-Signal Level: Blocked output (≤10 µA leakage)
- Switching Frequency: ≤ 5 kHz maximum
Safety & Isolation
- Safety Level: SIL 2, Systematic Capability SC 3
- Galvanic Isolation: Reinforced insulation 300 Veff
- Isolation Ratings: Input/Output: 300 Veff reinforced
- Hazardous Area: ATEX certified [Ex ia Ga] IIC
- Protection Degree: IP20 for indoor use
Configuration & Display
- Configuration: DIP switch settings
- Display Elements: LED status indicators
- Labeling: Front space for identification
- Operating Mode: Reversible operation possible
- Signal Splitting: 1 input to 2 outputs capability
Environmental Specifications
- Temperature Range: -20°C to +70°C standard
- Extended Range: Up to 70°C with derating
- Mounting: 35 mm DIN rail per EN 60715
- Dimensions: 12.5 x 119 x 114 mm (WxHxD)
- Weight: Approx. 100 grams
Certifications & Compliance
- ATEX Certificate: BASEEFA 13 ATEX 0080
- Marking: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC
- EMC Directive: 2014/30/EU, EN 61326-1:2013
- Safety Standards: IEC 61010-1:2010 compliance
Installation Guidelines
- Mount on 35 mm DIN rail in appropriate enclosure
- Connect 24V DC power via Power Rail or terminals
- Wire NAMUR sensor or dry contact to input terminals
- Connect outputs to control system inputs
- Configure DIP switches for required operation mode
- Verify proper grounding for hazardous area installation
Frequently Asked Questions (FAQ)
What is the main purpose of this switch amplifier?
The Pepperl+Fuchs KCD2-SOT-Ex1.LB safely interfaces hazardous area sensors with control systems.
Can I use this with standard mechanical contacts?
Yes, it accepts both NAMUR sensors and dry contact inputs.
What does "signal splitter" function mean?
It can take one input signal and provide two identical output signals.
How does line fault detection work?
It detects open circuits (<0.1 mA) and short circuits (>6.5 mA) in field wiring.
What hazardous area classifications does it support?
ATEX Zone 0/1 for gas and Zone 20/21 for dust explosive atmospheres.
What configuration options are available?
DIP switches allow setting operating mode, output configuration, and fault behavior.
For technical specifications or to order the KCD2-SOT-Ex1.LB, email sale@etowonauto.com.
Content provided by Etowon Auto.
Ek Özellikler
- Mavi
Skaler (V/f)
Vektör
AC ile çalışan
Satın Alma Rehberi
- Sipariş vermeden önce kesin model, parça numarası ve teknik özellikleri doğrulayın.
- Mevcut makine veya kontrol sistemlerinizle uyumluluğu kontrol edin.
- Teknik destek için sale@etowonauto.com adresinden veya +8617859788089 numarasından iletişime geçin.
- Teslimat seçeneklerini, teslim sürelerini ve nakliye gereksinimlerini inceleyin.
- Kurulum sırasında üretici talimatlarını ve en iyi uygulamaları takip edin.
Gönderim ve İade
Stokta bulunan ürünler genellikle aynı iş günü içinde gönderilir. Şu anda stokta olmayan ürünler için gönderim süreleri, ürünün bulunabilirliğine göre değişiklik gösterebilir. Uluslararası gönderim mevcuttur ve gönderim ücretleri varış yeri, ağırlık ve taşıyıcı seçimine göre hesaplanır.
Ürünler kullanılmamış ve orijinal durumda olmak koşuluyla, teslim alındıktan sonraki 30 gün içinde iade kabul edilir. İade gönderim ücretleri müşteriye aittir. Lütfen herhangi bir ürünü iade etmeden önce iade onayı almak için bizimle iletişime geçin.
Daha fazla bilgi için lütfen Gönderim ve İade Politikamızı inceleyin.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Hızlı Gönderim
Orijinal endüstriyel otomasyon parçaları, dünya çapında hızlı gönderim için mevcuttur.
-
Kolay İade
Güvenilir satış sonrası koruma için 12 aylık garanti ile 30 gün iade desteği.
-
7/24 destek
Kararlı ve verimli operasyonların sürdürülmesine yardımcı olmak için duyarlı profesyonel destek.
-
Orijinal ve Gerçek
%100 orijinal, güvenilir endüstriyel otomasyon üreticilerinden doğrudan temin edilmiştir.
Teknik ve Satın Alma Rehberi
-
Sürekli Otomasyon İterasyonu Fabrika Maliyetlerini %18-25 Azaltabilir mi?
Statik endüstriyel kontrol sistemleri, yıllık %18-25 arasında gizli maliyet artışlarına yol açar. Kademeli PLC ve DCS...
-
Parazit Önleyici Donanım Otomasyon Kesintilerinin %38'ini Sonlandırabilir mi?
Kimyasal, rüzgar ve otomotiv tesislerinden alınan saha verileri, tam IEC 61000-4 EMC sertifikalı endüstriyel donanımı...
-
Tam Yaşam Döngüsü Yönetimi PLC ve DCS Varlıklarını Nasıl Optimize Eder?
Geleneksel endüstriyel varlık yönetimi, manuel kayıt ve reaktif sorun giderme yöntemlerine dayanır; bu da yıllık %15-...
-
Entegre Yedek Zincir Kesinti Süresini Azaltabilir mi?
Planlanmamış ekipman arızaları Çin fabrikalarına saatte 636.000 ¥ maliyet çıkarıyor. Geleneksel sınır ötesi yedek par...
-
Otomasyon Yükseltmelerinin %30'u Entegrasyon Boşlukları Nedeniyle Neden Başarısız Oluyor?
Bu teknik makale, dijital-zekâ birleşiminin endüstriyel otomasyon (PLC, DCS, TSI, IIoT) kullanarak parçalanmış atölye...
-
Ağır Sanayiler Neden GE Fanuc PLC ve DCS Sistemlerine Güveniyor?
Bu makale, GE Fanuc temel bileşenlerinin ağır yük fabrika otomasyonundaki güvenilirlik boşluklarını nasıl çözdüğünü i...