Przejdź do treści
Części do automatyki, dostawa na cały świat
Pomiń, aby przejść do informacji o produkcie
1 z 3

SKU:KCD2-STC-EX1

Pepperl+Fuchs KCD2-STC-Ex1 Transmitter Power Supply

Pozostało tylko 10 sztuk
  • Manufacturer: Pepperl+Fuchs

  • Product No.: KCD2-STC-EX1

  • Product Type: Power Supply

  • Product Origin: DE

  • Payment:T/T, Western Union

  • Weight: 150g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-dniowa polityka zwrotów · 12-miesięczna gwarancja
  • Szybka dostawa
  • Wsparcie całodobowe
  • Zapewnienie jakości

Opis

Pepperl+Fuchs KCD2-STC-Ex1 SMART Transmitter Power Supply

The Pepperl+Fuchs KCD2-STC-Ex1 is a transmitter power supply for field instruments. This SMART device provides power to 2-wire transmitters in hazardous areas. It ensures reliable operation for analog measurement devices. The Pepperl+Fuchs KCD2-STC-Ex1 offers intrinsic safety for process control applications.

Product Identification

  • Manufacturer: Pepperl+Fuchs
  • Product Number: KCD2-STC-Ex1
  • Product Type: SMART Transmitter Power Supply
  • Signal Type: Analog Input for field transmitters
  • Connection Side: Field side installation
  • Protection Rating: IP20 enclosure

Power Specifications

  • Power Consumption: 1.1 Watt maximum
  • Power Connection: Power Rail or terminals 9+, 10-
  • Switching Frequency: < 10 Hz operation
  • Circuit Protection: Intrinsic safety design
  • Power Delivery: For 2-wire transmitters

Connection Details

  • Field Terminals: 1+, 2+, 3- for transmitter wiring
  • Connection Type: Screw terminal connections
  • Wiring: Supports standard field wiring
  • Installation: DIN rail mounting standard
  • Interface: Compatible with Power Rail system

Physical Specifications

  • Dimensions: 1.2 x 11.4 x 12.4 cm (W x H x D)
  • Weight: 0.15 kg (150 grams) net weight
  • Shipping Weight: 1.5 kg packaged weight
  • Enclosure: Compact industrial housing
  • Mounting: Standard 35mm DIN rail

Functional Characteristics

  • Transmitter Power: Supplies 2-wire field devices
  • Signal Conditioning: Analog input processing
  • Safety Design: Intrinsically safe for Ex areas
  • Monitoring: Transmitter status indication
  • Compatibility: Works with SMART transmitters

Environmental Ratings

  • Protection Class: IP20 for indoor use
  • Temperature Range: Standard industrial rating
  • Hazardous Areas: ATEX/IECEx certified
  • EMC Compliance: Industrial electromagnetic standards
  • Vibration: Suitable for industrial environments

Installation Guidelines

  • Mount on 35mm DIN rail in control cabinet
  • Connect power via Power Rail or terminal blocks
  • Wire field transmitter to terminals 1+, 2+, 3-
  • Follow intrinsic safety wiring requirements
  • Verify proper grounding and barrier installation
  • Check transmitter compatibility before connection

Certifications & Safety

  • Intrinsic Safety: Ex ia certification for Zone 0/1
  • ATEX: European hazardous area compliance
  • IECEx: International explosive atmosphere standards
  • Quality Standards: Pepperl+Fuchs manufacturing quality
  • EMC: Electromagnetic compatibility compliance

System Integration

  • Control Systems: Compatible with DCS and PLC systems
  • Transmitters: Supports SMART/HART field devices
  • Power Systems: Integrates with Power Rail distribution
  • Safety Systems: Suitable for SIL-rated applications
  • Networking: Process instrument network compatibility

Frequently Asked Questions (FAQ)

What type of transmitters does this power supply support?

The Pepperl+Fuchs KCD2-STC-Ex1 powers 2-wire SMART and HART transmitters with analog signals.

Can I use this in Zone 0 hazardous areas?

Yes, with proper installation it is certified for Zone 0/1 hazardous locations.

What is the Power Rail connection option?

Power Rail allows daisy-chain power connection without individual wiring to each device.

How many transmitters can one unit power?

Typically one transmitter per unit, depending on the transmitter's power requirements.

What wiring configuration do terminals 1+, 2+, 3- support?

These terminals accommodate standard 2-wire transmitter connections with signal and power.

Is special training required for installation?

Installation should be performed by qualified personnel familiar with intrinsic safety requirements.

For technical support or to order the KCD2-STC-Ex1, contact sale@etowonauto.com.

Content provided by Etowon Auto.

🏷️ Tags: Power Supply
  • Niebieski

Skalar (V/f)

Wektor

Zasilany prądem zmiennym

  • Potwierdź dokładny model, numer części oraz specyfikacje przed złożeniem zamówienia.
  • Upewnij się, że jest kompatybilny z Twoimi obecnymi maszynami lub systemami sterowania.
  • Skontaktuj się pod adresem sale@etowonauto.com lub pod numerem +8617859788089, aby uzyskać pomoc techniczną.
  • Sprawdź opcje dostawy, czas realizacji oraz wymagania dotyczące wysyłki.
  • Postępuj zgodnie z instrukcjami producenta i najlepszymi praktykami podczas instalacji.

Produkty dostępne w magazynie są zazwyczaj wysyłane tego samego dnia roboczego. W przypadku produktów chwilowo niedostępnych czas wysyłki może się różnić w zależności od dostępności. Oferujemy wysyłkę międzynarodową, a koszty przesyłki są obliczane na podstawie miejsca docelowego, wagi oraz wybranego przewoźnika.

Zwroty są akceptowane w ciągu 30 dni od otrzymania, pod warunkiem, że produkty są nieużywane i w oryginalnym stanie. Koszty zwrotu ponosi klient. Prosimy o kontakt przed zwrotem jakiegokolwiek produktu, aby uzyskać autoryzację zwrotu.

Więcej informacji znajdziesz w naszej Polityce wysyłki i zwrotów.

Pokaż kompletne dane

ZAPEWNIJ NIEZAWODNĄ PRACĘ MASZYN

Przekształć swój dom dzięki najnowszym rozwiązaniom multi-elektronicznym, od inteligentnego oświetlenia po urządzenia sterowane głosem — wszystko zaprojektowane, aby życie było łatwiejsze, bezpieczniejsze i bardziej połączone.

Optymalizuj swoje operacje dzięki systemowi monitorowania Bently Nevada 3500, oferującemu monitorowanie drgań i stanu maszyn w czasie rzeczywistym, aby zapobiegać awariom i maksymalizować czas pracy.