Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:IS200EDCFG1A
GE IS200EDCFG1A EDCF Exciter DC Feedback Module EX2100
Manufacturer: General Electric
Product No.: IS200EDCFG1A
Product Type: Feedback Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
Product Overview
The General Electric IS200EDCFG1A (functional acronym EDCF) is an Exciter DC Feedback Board designed for the GE EX2100 Series Excitation Control System. Mounted directly at the Silicon Controlled Rectifier (SCR) bridge, this module measures and conditions critical generator field voltage and field current feedback signals for real-time excitation control.
To ensure high noise immunity and complete electrical isolation in harsh high-voltage power generation environments, the IS200EDCFG1A converts analog voltage and current inputs into high-speed fiber-optic pulse streams transmitted directly to the EISB board in the control rack. Operating on an external 24 V DC power supply, the board weighs approximately 0.45 kg (0.99 lbs) and is rated for operation across temperatures ranging from -30°C to +65°C.
Core Technical Advantages
- Noise-Immune Fiber-Optic Transmission: Utilizes dual fiber-optic links (plastic for up to 10 m, hard-clad silica for up to 90 m) to transmit isolated feedback signals without electromagnetic interference.
- Selectable Field Voltage Scaling: Provides seven adjustable jumper settings to attenuate and scale SCR bridge voltages before feeding differential VCO circuitry.
- Precision Field Current Measurement: Monitors low-level DC shunt outputs (up to 500 mV) and amplifies them into a -5V to +5V range for high-accuracy current tracking.
- Onboard Voltage Regulation: Converts external 24 V DC power into isolated +15 VDC, -15 VDC, and +5 VDC rails, featuring a front-panel PSOK green LED indicator.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | General Electric (GE) |
| Catalog Part Number | IS200EDCFG1A |
| Functional Acronym | EDCF (Exciter DC Feedback Board) |
| System Compatibility | GE EX2100 Excitation Control System |
| Hardware Revision / Form | Hardware Form A (Not Backward Compatible) |
| External Power Supply | 24 V DC (via Connector J16) |
| Internal Voltage Rails | +15 VDC, -15 VDC, +5 VDC (regulated onboard) |
| Field Voltage Input | Stab-on terminal E1 (7 jumper-selectable scaling settings) |
| Field Current Input | Connector P1 (DC shunt low-level signal up to 500 mV max) |
| Fiber-Optic Distances | Plastic: up to 10 m; Hard-Clad Silica: up to 90 m |
| Net Board Weight | 0.45 kg (0.99 lbs) |
| Operating Temperature | -30°C to +65°C (-22°F to +149°F) |
| Documentation Manuals | GEI-100464 / GEI-100464A, GEH-6632 |
Installation & Gap Calibration Guide
- Wiring Connections: Attach the 24 V DC supply to connector J16, the current shunt signal to P1, and the field voltage sensing line to stab-on connector E1.
- Fiber-Optic Cable Routing: Route two fiber-optic cables from the EDCF to the EISB board, ensuring a minimum bending radius of 1.5 inches (38 mm) to avoid signal degradation.
- Power Verification: Confirm that the green PSOK LED illuminates upon applying 24 V DC, verifying correct function of the internal ±15 VDC regulators.
Technical FAQs
Q1: What is the main function of the GE IS200EDCFG1A board?
A1: It senses field voltage/current at the SCR bridge and transmits optical data to the EISB board. (95 chars)
Q2: What cable types and distances are supported for fiber transmission?
A2: Plastic fiber supports distances up to 10 m, while hard-clad silica fiber reaches up to 90 m. (93 chars)
Q3: How is field current measured by the IS200EDCFG1A module?
A3: It measures a 500 mV max DC shunt voltage across connector P1, converting it into a VCO frequency. (96 chars)
Spesifikasi Tambahan
- Hijau
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...
-
What Makes Bently Nevada System 1 Essential for Predictive Maintenance?
Bently Nevada System 1 is a dedicated vibration analytics platform that pairs with 3500 TSI racks to deliver hig...
-
Is ABB MOD300 DCS Migration Still Worth the Investment?
ABB Advant MOD300 systems still run in many refineries and power plants, yet aging capacitors, scarce spares and hidd...