Langkau ke kandungan
Bahagian automasi, bekalan seluruh dunia
Langkau ke maklumat produk
1 daripada 3

SKU:3BSE088386R1

ABB PM857K02 Redundant Safety PLC Kit Controller

Stok ada (26 unit), sedia untuk dihantar
  • Manufacturer: ABB

  • Product No.: 3BSE088386R1

  • Product Type: Controller Module

  • Product Origin: SE

  • Payment:T/T, Western Union

  • Weight: 2700g

  • Shipping port: Xiamen

  • Warranty: 12 months

Polisi Pemulangan 30 Hari · Jaminan 12 Bulan
  • Penghantaran Pantas
  • Sokongan 24/7
  • Jaminan Kualiti

Penerangan

ABB PM857K02 Redundant Safety Controller Kit

The 3BSE088386R1 (PM857K02) is a complete ABB AC 800M High Integrity redundant controller kit. This package includes two PM857K01 safety processor units and necessary cables to establish a fully redundant system. It is engineered for critical applications demanding maximum availability and functional safety up to SIL 3.

Core Technical Specifications

  • Brand & Model: ABB PM857K02 (Article: 3BSE088386R1)
  • Package Contents: 2x PM857K01 CPUs, 1x TK850 CEX-bus cable, 1x TK851 RCU-Link cable.
  • Redundancy: Yes, configured for CPU redundancy with <10 ms switchover time.
  • Safety Certification: Up to SIL 3 with SM812 module; TÜV certified.
  • CPU Specs: MPC866 @ 96 MHz, 32 MB RAM (22 MB for application).
  • I/O Capacity: Max 128 signals; supports S800 I/O High Integrity.
  • Communication: 2x Ethernet, 2x RS-232C ports per controller.
  • Power Supply: 24 V DC (19.2-30V).

Physical Data, Features & Certifications

  • Weight: 2700 grams (approximately 5.95 lbs) for the complete kit.
  • Dimensions per Unit: 119 mm x 186 mm x 135 mm (W x H x D).
  • Key Feature: Combines standard process control and SIL 3 safety logic in one platform.
  • Configuration: Requires ABB 800xA Control Builder.
  • Certifications: CE, cULus (Class 1, Zone 2), TÜV, ISA Secure, RoHS, marine (ABS, BV, DNV-GL).
  • Operating Temperature: +5°C to +55°C.

Frequently Asked Questions

  • Q: What is included in this kit versus buying a single PM857?
    A> This PM857K02 kit includes two controller units and the essential cables to connect them for a redundant pair, providing a ready-to-deploy high-availability solution.
  • Q: Is the SM812 safety module included?
    A> No. The SM812 module is required to achieve SIL 2/3 functionality and must be purchased separately.
  • Q: What is the main benefit of redundancy?
    A> It ensures continuous operation; if the primary CPU fails, the backup takes over within milliseconds, preventing process downtime.
🏷️ Tags: Controller Module

Skalar (V/f)

Vektor

Dikuasakan oleh AC

  • Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
  • Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
  • Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
  • Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
  • Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.

Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.

Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.

Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

Lihat Butiran Produk

PASTIKAN PRESTASI MESIN YANG BOLEH DIPERCAYAI

Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.