Trasforma la tua casa con le ultime soluzioni multi-elettroniche, dall'illuminazione intelligente ai dispositivi controllati tramite voce, tutti progettati per rendere la vita più facile, sicura e connessa. Ottimizza le tue operazioni con il Sistema di Monitoraggio Bently Nevada 3500, che offre il monitoraggio in tempo reale delle vibrazioni e delle condizioni delle macchine per prevenire guasti e massimizzare il tempo di attività.
SKU:1756-CN2
Allen-Bradley 1756-CN2 ControlLogix ControlNet Bridge Module
Manufacturer: Allen-Bradley
Product No.: 1756-CN2
Product Type: EtherNet Bridge Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 260g
Shipping port: Xiamen
Warranty: 12 months
Condividi
- Consegna Veloce
- Assistenza 24 ore su 24, 7 giorni su 7
- Assicurazione della qualità
Descrizione
Product Overview
The Allen-Bradley 1756-CN2 is a high-performance ControlNet bridge module designed for the rugged ControlLogix automation environment. Acting as a deterministic communications interface, this module establishes high-speed, real-time links between ControlLogix controllers and distributed I/O racks, variable frequency drives, or other intelligent field platforms. Weighing a compact 0.26 kg (0.57 lbs), the single-slot 1756-CN2 routes scheduled and unscheduled peer-to-peer data over a reliable 5 Mbps ControlNet network line, ensuring deterministic timing that is completely unaffected by changes in node configuration or general network traffic overhead.
Core Technical Advantages
- High-Capacity Network Bridging: Manages up to 131 total connections (including 100 dedicated Logix communication paths and separate unscheduled channels) to efficiently facilitate dense, factory-wide controller message routing.
- Deterministic High-Speed Backplane: Utilizes a fixed 5 Mbps ControlNet communication rate to ensure time-critical interlocking data arrives precisely when expected, avoiding the jitter or packet collisions common in non-deterministic architectures.
- Rugged Environmental Engineering: Rated for operational shock conditions up to 30G and 2.0G of continuous mechanical vibration, this module delivers robust hardware endurance across an industrial temperature envelope of 0 to 60 degrees Celsius.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation (ControlLogix Series) |
| Model Part Number | 1756-CN2 |
| Gross Weight | 0.26 kg (0.57 lbs) |
| Interface Network Type | ControlNet coax-cable interface framework |
| Communication Rate | 5 Mbps fixed industrial network speed |
| Maximum Connections | 131 total (100 dedicated Logix connections + unscheduled buffer allocations) |
| Backplane Slot Width | Single-slot physical format |
| Backplane Current Draw | 1100 mA at 5.1 VDC / 3 mA at 24 VDC bus lines |
| Thermal / Power Dissipation | 5.6 Watts power loss / 19.1 BTU/hour thermal dissipation |
| Industrial HazLoc Ratings | Temperature Code T4A (North America) / IEC T4 (Europe) |
Installation & Engineering Guide
- Chassis Slot Installation: Isolate power to the local ControlLogix rack housing before mounting. Align the 0.26 kg communication hardware card inside the physical guide rails of any open slot, pushing straight back until the dual locking clips snap securely onto the structural frame.
- Coaxial Tap Connectivity: Wire the ControlNet network link using standard RG-6 coaxial cables and approved ControlNet taps. Ensure that the active node switches on the front panel or configuration software are addressed uniquely before applying power to prevent network communication faults.
- Network Update Interval (NUT) Tuning: Use RSNetWorx for ControlNet to properly schedule network data traffic. The 1756-CN2 allows you to prioritize time-sensitive interlocking signals via the scheduled data band while routing broad diagnostic diagnostic data via unscheduled slots.
Technical FAQs
Q1: What does "deterministic communication" mean when utilizing the 1756-CN2 on ControlNet?
A1: Deterministic communication means that the transmission time for your critical system data is mathematically guaranteed. Unlike standard Ethernet networks where packet collisions can cause unexpected execution delays, the 5 Mbps ControlNet frame provides a predictable schedule so that I/O states updates are delivered reliably cycle after cycle.
Q2: How does the 1756-CN2 module balance scheduled versus unscheduled traffic?
A2: The module manages a total budget of 131 connections. It reserves 100 solid paths for scheduled Logix controller updates (like safety lines or remote I/O loops), leaving the remaining buffer slots available for unscheduled actions like loading programs, checking web pages, or pulling non-critical hardware diagnostics.
Q3: Does the low 0.26 kg weight profile mean the hardware is prone to damage in heavy manufacturing settings?
A3: No. The efficient 0.26 kg structural weight is the result of a compact, single-slot integration strategy. The internal electronics are fully engineered to withstand up to 30G of operational shock forces and 2.0G of industrial vibration without losing backplane connectivity.
Specifiche aggiuntive
Scalare (V/f)
Vettore
Alimentato a corrente alternata
Guida all'acquisto
- Conferma il modello esatto, il numero di parte e le specifiche prima di ordinare.
- Verifica la compatibilità con la tua macchina o i sistemi di controllo attuali.
- Contatta sale@etowonauto.com o +8617859788089 per assistenza tecnica.
- Esamina le opzioni di consegna, i tempi di attesa e i requisiti di spedizione.
- Segui le istruzioni del produttore e le migliori pratiche durante l’installazione.
Spedizione e Resi
Gli articoli disponibili in magazzino vengono solitamente spediti lo stesso giorno lavorativo. Per i prodotti non attualmente disponibili, i tempi di spedizione possono variare in base alla disponibilità. La spedizione internazionale è disponibile e i costi di spedizione sono calcolati in base alla destinazione, al peso e al corriere scelto.
Le restituzioni sono accettate entro 30 giorni dal ricevimento, a condizione che gli articoli siano inutilizzati e nelle condizioni originali. Le spese di spedizione per la restituzione sono a carico del cliente. Si prega di contattarci prima di restituire qualsiasi articolo per ricevere l'autorizzazione al reso.
Per maggiori dettagli, si prega di consultare la nostra Politica di Spedizione e Reso.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Spedizione Veloce
Ricambi originali per automazione industriale disponibili per spedizione rapida in tutto il mondo.
-
Resi Facili
Supporto per resi entro 30 giorni con garanzia di 12 mesi per una protezione post-vendita affidabile.
-
Supporto 24/7
Supporto professionale reattivo per aiutare a mantenere operazioni stabili ed efficienti.
-
Autentico e Originale
100% autentico, proveniente direttamente da produttori affidabili di automazione industriale.
Guida tecnica e all'acquisto
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...