Transformez votre maison avec les dernières solutions multi-électroniques, de l’éclairage intelligent aux appareils commandés par la voix, tous conçus pour rendre la vie plus facile, plus sûre et plus connectée. Optimisez vos opérations avec le système de surveillance Bently Nevada 3500, offrant une surveillance en temps réel des vibrations et de l’état des machines pour prévenir les pannes et maximiser le temps de fonctionnement.
SKU:TSXH5724M
TSXH5724M Schneider Electric Modicon Premium Processor Module
Manufacturer: Schneider
Product No.: TSXH5724M
Product Type: Processor Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 560g
Shipping port: Xiamen
Warranty: 12 months
Partager
- Livraison rapide
- Assistance 24h/24 et 7j/7
- Assurance qualité
Description
Product Overview
The TSXH5724M is a double-format Unity Hot Standby PLC processor module from Schneider Electric's Modicon Premium Automation platform series. Designed for high-availability industrial automation, this processor supports up to 1024 discrete I/O points, 80 analog I/O points, and 24 application-specific channels. Weighing 1.23 lbs (0.56 kg), it features built-in Ethernet TCP/IP (10BASE-T/100BASE-TX), a USB Type-A port, and an RS485 mini-DIN serial connection to deliver reliable high-speed process control across 6, 8, or 12-slot racks.
Core Technical Advantages
- Unity Hot Standby Redundancy: Provides real-time CPU synchronization via a high-speed 192 kB data exchange link to ensure uninterrupted system uptime.
- Flexible Memory Architecture: Features 192 kB internal RAM for program/data (expandable to 768 kB program RAM with a 16,384 kB PCMCIA data card).
- High-Speed Execution: Processes Boolean instructions in 0.039 to 0.057 μs with throughput up to 15.75 Kinst/ms for fast logic execution.
- Integrated Connectivity: Built-in RJ45 Ethernet TCP/IP port, USB port (12 Mbit/s), and non-isolated mini-DIN RS485 serial port simplify field networking.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer & Line | Schneider Electric / Modicon Premium Automation Platform |
| Part Catalog Number | TSXH5724M (GTIN: 3595863921243) |
| Product / Component Type | Unity Hot Standby Redundant Processor Module |
| Software Designation | Unity Pro Programming Environment |
| I/O Processing Capacities | 1024 Discrete I/O; 80 Analog I/O; 24 Application-Specific Channels |
| Process Control Capacity | 10 Process Control Channels (up to 30 simple control loops) |
| Integrated Connections | Ethernet TCP/IP RJ45; USB Type-A (12 Mbit/s); Mini-DIN RS485 (19.2 kbit/s) |
| Memory Configuration | 192 kB RAM (Internal); Expandable with 16,384 kB PCMCIA Memory Card |
| Module Physical Format & Mass | Double Slot Format; Net Mass: 1.23 lbs (0.56 kg) |
| Power & Current Draw | 1880 mA @ 5 V DC internal bus power |
| Certifications & Protection | CE, UL 508, CSA Class I Div 2, IP20, Marine Rated (ABS, DNV, GL, LR) |
Industrial Solutions
- Continuous Process Plants: Deploys in Unity Hot Standby configurations to ensure seamless CPU failover in critical manufacturing.
- Water & Wastewater Treatment: Manages up to 30 process loops and distributed remote I/O bases via Ethernet TCP/IP networks.
- Marine & Offshore Automation: Marine-certified (ABS, DNV, LR, BV) for reliable vessel power management and engine room monitoring.
- High-Density Factory Control: Coordinates up to 1024 discrete I/O channels across 6, 8, or 12-slot Modicon Premium backplanes.
Wiring & Installation
Rack Insertion & Power Protocols
Ensure backplane power is shut off before installing the TSXH5724M into a 6, 8, or 12-slot Modicon Premium rack base. Seat the double-format module firmly into its assigned slots until the top and bottom retaining clips latch completely.
Ethernet & Sync Link Connections
Connect standard shielded RJ45 CAT5e/CAT6 cables to the 10BASE-T/100BASE-TX Ethernet port. When building a Hot Standby system, connect the CPU Sync link cable between primary and standby processors to maintain the 192 kB sync data area.
Serial TER/AUX & USB Port Interface
Use the female mini-DIN RS485 terminal port (19.2 kbit/s) or the USB Type-A port (12 Mbit/s) for programming cables, operator interfaces, or peripheral device commissioning using Unity Pro software.
LED Diagnostics Verification
Upon powering up the 5 V DC supply (1880 mA current draw), verify that the green RUN LED illuminates solid. Check that ERR, I/O, and COL fault LEDs remain dark before switching the system to operational mode.
Engineering Advantages
- Fast Instruction Execution: Executes Boolean commands at 0.039 μs and floating-point math at 0.055 μs for responsive loop execution.
- Comprehensive Marine & Explosive Approvals: Approved for CSA Class I Div 2 hazardous locations and major marine classification standards.
- Diagnostic LED Array: Features 10 status LEDs on the front panel providing instant visual diagnostics for CPU, Ethernet, and port activity.
Technical FAQs
Q1: What software is required to program the TSXH5724M processor?
A1: Configured and programmed using Schneider Electric Unity Pro software.
Q2: What are the memory specs with and without a PCMCIA card?
A2: Without card: 192 kB RAM. With card: 768 kB program, 192 kB data, 16384 kB PCMCIA.
Q3: What is the physical weight and power consumption of TSXH5724M?
A3: Module weighs 1.23 lbs (0.56 kg) and draws 1880 mA at 5 V DC.
Spécifications supplémentaires
- Gris
- Argent
Scalaire (V/f)
Vecteur
Alimenté par courant alternatif
Guide d'achat
- Confirmez le modèle exact, le numéro de pièce et les spécifications avant de commander.
- Assurez-vous de la compatibilité avec votre machine ou vos systèmes de contrôle actuels.
- Contactez-nous via sale@etowonauto.com ou au +8617859788089 pour une assistance technique.
- Examinez les options de livraison, les délais et les exigences d’expédition.
- Suivez les instructions du fabricant et les bonnes pratiques lors de l’installation.
Expédition et retour
Les articles en stock sont généralement expédiés le jour même. Pour les produits actuellement en rupture de stock, les délais d'expédition peuvent varier en fonction de la disponibilité. La livraison internationale est disponible, et les frais de port sont calculés selon la destination, le poids et le transporteur choisi.
Les retours sont acceptés dans un délai de 30 jours après réception, à condition que les articles soient inutilisés et en état d'origine. Les frais de retour sont à la charge du client. Veuillez nous contacter avant de retourner un article afin d'obtenir une autorisation de retour.
Pour plus de détails, veuillez consulter notre Politique d'expédition et de retour.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Livraison rapide
Pièces d'automatisation industrielle d'origine disponibles pour expédition rapide dans le monde entier.
-
Retours Faciles
Support de retour sous 30 jours avec une garantie de 12 mois pour une protection après-vente fiable.
-
Assistance 24h/24 et 7j/7
Support professionnel réactif pour aider à maintenir des opérations stables et efficaces.
-
Authentique & Original
100 % authentique, provenant directement de fabricants fiables d'automatisation industrielle.
Guide technique et d'achat
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...
-
Why Do Bently Nevada TSI Sensors Need Single-Point Grounding?
Poor grounding in Bently Nevada TSI systems creates millivolt-level noise that masks real vibration signals and trigg...