MTL Instruments | MTL5018 Dual Channel Controller

En stock (25 unités), prêt à être expédié
  • Manufacturer: MTL

  • Product No.: MTL5018

  • Product Type: Detector Interface

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 110g

  • Shipping port: Xiamen

  • Warranty: 12 months

Politique de retour sous 30 jours · Garantie de 12 mois
  • Livraison rapide
  • Assistance 24h/24 et 7j/7
  • Assurance qualité

Description

MTL5018 Dual Channel Relay Interface

The MTL5018 from MTL Instruments provides dual-channel control of safe-area loads from hazardous area switches and proximity detectors. This advanced interface features two independent relay outputs with comprehensive safety features including line fault detection and phase reversal control for each channel.

Key Technical Specifications

  • Brand: MTL Instruments
  • Model: MTL5018
  • Product Type: Dual Channel Relay Interface
  • Channels: Two independent channels
  • Outputs: Two changeover relays
  • Response Time: 10ms maximum
  • Input Standard: NAMUR/DIN 19234

Hazardous Area Certification

  • Switch Location: Zone 0, IIC, T6 hazardous area
  • Detector Location: Zone 0, IIC, T4-T6 with certification
  • Division Rating: Division 1, Group A hazardous location
  • The MTL5018 maintains intrinsic safety for both channels

Input Specifications

  • Sensor Voltage: 7 to 9V from 1kΩ ±10% source per channel
  • Normal Phase: Output energizes if Iin >2.1mA or Rin <2kΩ
  • Reverse Phase: Output de-energizes under same conditions
  • Hysteresis: 200µA typical per channel for stable switching
  • Phase Reversal: Independent for each channel, user-selectable

Relay Output Characteristics

  • Relay Type: Two single-pole changeover contacts
  • Contact Rating AC: 250V AC, 2A, cosø >0.7
  • Contact Rating DC: 40V DC, 2A, resistive load
  • Response Time: 10ms maximum per channel
  • Note: Reactive loads require adequate suppression

Line Fault Detection (LFD)

  • LFD Mode: User-selectable via top switches for each channel
  • Open-circuit Alarm: On if Iin <100µA, Off if Iin >250µA
  • Short-circuit Alarm: On if Rin <100Ω, Off if Rin >360Ω
  • Fault Response: Detected line fault de-energizes the relay
  • Contact Input: Requires 500Ω-1kΩ series and 20kΩ-25kΩ parallel resistors

Terminal Configuration

  • Channel 1 Input: Terminal 1 (Input –ve), Terminal 2 (Input +ve)
  • Channel 2 Input: Terminal 4 (Input –ve), Terminal 5 (Input +ve)
  • Earth Leakage: Terminal 3 (Ch 1), Terminal 6 (Ch 2) for detection
  • Channel 1 Output: Terminal 10 (NC), 11 (Common), 12 (NO)
  • Channel 2 Output: Terminal 7 (NC), 8 (Common), 9 (NO)
  • Power Supply: Terminal 13 (Supply –ve), Terminal 14 (Supply +ve)

Power Requirements

  • Current Consumption: 60mA at 24V maximum
  • Power Dissipation: 1.4W at 24V maximum
  • Maximum Dissipation: 1.5W at 35V
  • Isolation: 250V AC or DC between all circuits

Safety Parameters

  • Safety Voltage: 10.5V maximum per channel
  • Internal Resistance: 800Ω per channel
  • Safety Current: 14mA maximum per channel
  • Maximum Voltage: Um = 250V rms or DC

Frequently Asked Questions

  • How many loads can the MTL5018 control?
    It can control two independent safe-area loads from two hazardous area inputs.
  • Are the channels independently configurable?
    Yes, each channel has independent phase reversal and line fault detection.
  • How does line fault detection work?
    It detects open circuits (<100µA) and short circuits (<100Ω) with individual channel indication.
  • What is the relay response time?
    The relays respond within 10ms maximum for each channel.

For pricing and technical support, please contact sale@etowonauto.com

🏷️ Tags: Detector Interface

Scalaire (V/f)

Vecteur

Alimenté par courant alternatif

  • Confirmez le modèle exact, le numéro de pièce et les spécifications avant de commander.
  • Assurez-vous de la compatibilité avec votre machine ou vos systèmes de contrôle actuels.
  • Contactez-nous via sale@etowonauto.com ou au +8617859788089 pour une assistance technique.
  • Examinez les options de livraison, les délais et les exigences d’expédition.
  • Suivez les instructions du fabricant et les bonnes pratiques lors de l’installation.

Les articles en stock sont généralement expédiés le jour même. Pour les produits actuellement en rupture de stock, les délais d'expédition peuvent varier en fonction de la disponibilité. La livraison internationale est disponible, et les frais de port sont calculés selon la destination, le poids et le transporteur choisi.

Les retours sont acceptés dans un délai de 30 jours après réception, à condition que les articles soient inutilisés et en état d'origine. Les frais de retour sont à la charge du client. Veuillez nous contacter avant de retourner un article afin d'obtenir une autorisation de retour.

Pour plus de détails, veuillez consulter notre Politique d'expédition et de retour.

Afficher tous les détails

ASSURER UNE PERFORMANCE FIABLE DES MACHINES

Transformez votre maison avec les dernières solutions multi-électroniques, de l’éclairage intelligent aux appareils commandés par la voix, tous conçus pour rendre la vie plus facile, plus sûre et plus connectée. Optimisez vos opérations avec le système de surveillance Bently Nevada 3500, offrant une surveillance en temps réel des vibrations et de l’état des machines pour prévenir les pannes et maximiser le temps de fonctionnement.