Transformez votre maison avec les dernières solutions multi-électroniques, de l’éclairage intelligent aux appareils commandés par la voix, tous conçus pour rendre la vie plus facile, plus sûre et plus connectée. Optimisez vos opérations avec le système de surveillance Bently Nevada 3500, offrant une surveillance en temps réel des vibrations et de l’état des machines pour prévenir les pannes et maximiser le temps de fonctionnement.
SKU:BMXP3420302CL
BMXP3420302CL Schneider Electric | No Memory Card Included
Manufacturer: Schneider
Product No.: BMXP3420302CL
Product Type: Processor Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 215g
Shipping port: Xiamen
Warranty: 12 months
Partager
- Livraison rapide
- Assistance 24h/24 et 7j/7
- Assurance qualité
Description
Schneider Electric BMXP3420302CL Modicon M340 Processor
Product Overview
The Schneider Electric BMXP3420302CL is a processor module for the Modicon M340 automation platform with CANopen master bus and Transparent Ready concepts. It supports up to 1024 discrete and 256 analog I/O in multi-rack configuration, featuring Ethernet, CANopen, and USB connectivity plus independent axis motion control. This version requires a memory card to work (not supplied). Weight is 0.215 kg.
Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Model | BMXP3420302CL |
| Product Line | Modicon M340 |
| Product Type | Processor Module |
| Condition of Use | Requires Memory Card to Work (Not Supplied) |
| Number of Racks | 4 |
| Number of Slots | 11 |
| Discrete I/O (Multi-Rack) | 1024 I/O |
| Discrete I/O (Single-Rack) | 704 I/O |
| Analog I/O (Multi-Rack) | 256 I/O |
| Analog I/O (Single-Rack) | 66 I/O |
| Application Specific Channels | 36 |
| Motion Control | Independent Axis CANopen |
| Integrated Connections | USB 12 Mbit/s, CANopen Master SUB-D 9 (20 kbit/s to 1 Mbit/s), Ethernet TCP/IP 10/100 |
| Communication Module Capacity | 2 Ethernet, 4 AS-Interface |
| Ethernet Port | 10BASE-T/100BASE-TX |
| CANopen Server Devices | 63 |
| CANopen Bus Type | DS 301 V4.02, DS 303-2, DS 405 (Daisy-Chain or Tap Junction) |
| Internal RAM Total | 4096 kB |
| Data RAM | 256 kB |
| Program RAM | 3584 kB (Constants and Symbols) |
| Application Structure | 1 Cyclic/Periodic Master, 1 Periodic Fast, 64 Event Tasks |
| Execution Time (Boolean) | 0.12 µs |
| Execution Time (Floating Point) | 1.16 µs |
| Instructions per ms | 6.4 Kinst/ms (65% Boolean + 35% fixed), 8.1 Kinst/ms (100% Boolean) |
| Current Consumption | 135 mA @ 24 VDC |
| Protection Rating | IP20 |
| Operating Temperature | 0 to 60 °C |
| Relative Humidity | 10-95% (Non-Condensing) |
| Weight | 0.215 kg |
CANopen and Communication Features
- CANopen Network Management (NMT)
- Process Data Object (PDO) and Service Data Object (SDO)
- Special Functions: SYNC, EMCY, TIME
- CANopen Master Bus at 20 kbit/s to 1 Mbit/s
- Bandwidth Management (Ethernet TCP/IP)
- Data Editor and Rack Viewer (Ethernet TCP/IP)
- Modbus TCP Messaging (Ethernet TCP/IP)
- SNMP Network Administrator (Ethernet TCP/IP)
Certifications
- CE, UL, CSA, RCM, EAC
- Merchant Navy
- IEC 61131-2, IEC 61010-2-201
- UL 61010-2-201, CSA C22.2 No 61010-2-201
- IACS E10
- EN/IEC 61000-6-5 Interface Type 1 and 2
- EN/IEC 61850-3 Location G
- Hazardous Location Class I Division 2
Key Features
- Requires a memory card to operate (not supplied)
- Supports 1024 discrete and 256 analog I/O in multi-rack configuration
- Integrated CANopen master bus for motion control and distributed devices
- Independent axis motion control via CANopen
- Supports 63 CANopen server devices
- Dual connectivity: Ethernet TCP/IP and CANopen SUB-D 9
- 36 application-specific channels for specialized control
- Fast execution: 0.12 µs Boolean instruction time
- CANopen diagnostics LEDs for RUN and ERR status
- Supports 2 Ethernet and 4 AS-Interface communication modules
- Class I Division 2 hazardous location approved
- Marine certified for merchant navy applications
Installation Notes
Install the processor in a Modicon M340 rack with internal power supply. A memory card must be installed for the processor to operate; it is not included with this version. Connect CANopen devices using the SUB-D 9 master bus, observing transmission rate limits: 1 Mbit/s up to 20 m, 125 kbit/s up to 500 m, and 20 kbit/s up to 2500 m. Configure independent axis motion control for CANopen drives. Connect Ethernet devices using the 10BASE-T/100BASE-TX port. The USB port supports local programming at 12 Mbit/s. Monitor CAN RUN and CAN ERR LEDs for bus status. Maintain operating temperature between 0 and 60 °C.
FAQs
Q1: Does the BMXP3420302CL include a memory card?
A1: No. This version requires a memory card to work, but the card is not supplied and must be purchased separately.
Q2: What CANopen capabilities does this processor offer?
A2: CANopen master bus supporting NMT, PDO, SDO, and special functions (SYNC, EMCY, TIME), with up to 63 server devices and independent axis motion control.
Q3: What is the maximum CANopen bus length?
A3: Up to 2500 meters at 20 kbit/s, 500 meters at 125 kbit/s, or 20 meters at 1 Mbit/s.
Spécifications supplémentaires
- Alimenté en courant continu
- Compact
Scalaire (V/f)
Vecteur
Alimenté par courant alternatif
Guide d'achat
- Confirmez le modèle exact, le numéro de pièce et les spécifications avant de commander.
- Assurez-vous de la compatibilité avec votre machine ou vos systèmes de contrôle actuels.
- Contactez-nous via sale@etowonauto.com ou au +8617859788089 pour une assistance technique.
- Examinez les options de livraison, les délais et les exigences d’expédition.
- Suivez les instructions du fabricant et les bonnes pratiques lors de l’installation.
Expédition et retour
Les articles en stock sont généralement expédiés le jour même. Pour les produits actuellement en rupture de stock, les délais d'expédition peuvent varier en fonction de la disponibilité. La livraison internationale est disponible, et les frais de port sont calculés selon la destination, le poids et le transporteur choisi.
Les retours sont acceptés dans un délai de 30 jours après réception, à condition que les articles soient inutilisés et en état d'origine. Les frais de retour sont à la charge du client. Veuillez nous contacter avant de retourner un article afin d'obtenir une autorisation de retour.
Pour plus de détails, veuillez consulter notre Politique d'expédition et de retour.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Livraison rapide
Pièces d'automatisation industrielle d'origine disponibles pour expédition rapide dans le monde entier.
-
Retours Faciles
Support de retour sous 30 jours avec une garantie de 12 mois pour une protection après-vente fiable.
-
Assistance 24h/24 et 7j/7
Support professionnel réactif pour aider à maintenir des opérations stables et efficaces.
-
Authentique & Original
100 % authentique, provenant directement de fabricants fiables d'automatisation industrielle.
Guide technique et d'achat
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...