{"product_id":"siemens-6es7422-5eh10-0ab0-sm-422-do-16-module","title":"Siemens 6ES7422-5EH10-0AB0 | SM 422 DO 16 Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eSiemens 6ES7422-5EH10-0AB0\u003c\/strong\u003e is an SM 422 digital output module for the SIMATIC S7-400 automation system. It provides 16 isolated outputs rated for DC 20-125 V with 1.5 A output current. Weighing approximately 1.02 kg, this module delivers reliable actuator control with integrated diagnostics and electronic short-circuit protection for demanding industrial applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThis module offers 16 outputs arranged in two groups of 8. Output voltage for signal \"1\" is minimum L+ (-1.0 V) with a permitted current range of 10 mA to 1.5 A and peak current up to 3 A for 10 ms. Output delay is maximum 2 ms from \"0\" to \"1\" and maximum 13 ms from \"1\" to \"0\" for resistive loads. Parallel connection of two outputs supports redundant load control and performance enhancement within the same group.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6ES7422-5EH10-0AB0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSM 422 Digital Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC S7-400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e16, isolated in 2 groups of 8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDC 20-125 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Current (Rated)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Current Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e10 mA to 1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePeak Current\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax 3 A for 10 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eResidual Current (Signal 0)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax 0.5 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Delay (0 to 1)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax 2 ms (resistive load)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Delay (1 to 0)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax 13 ms (resistive load)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSwitching Frequency (Resistive)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax 10 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSwitching Frequency (Inductive)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax 0.5 Hz (IEC 947-5-1, DC 13)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShort-Circuit Protection\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eElectronic, threshold typically 4 to 5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eReplacement Fuse\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8 A \/ 250 V, fast-acting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eParallel Outputs\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSupported (same group only)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eApprox. 1.02 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eInstall the SM 422 module in a compatible S7-400 rack slot and secure the front connector. Before replacing the fuse, always unplug the front connector to prevent electric shock hazard. Distribute high-current loads between the two output groups for optimal performance. To reset a disconnected output after a short circuit, first set the output signal to 0, then back to 1. Mechanical power contact may produce voltage pulses lasting up to 0.5 ms at the outputs.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThis module provides 16 isolated outputs in two groups, enabling flexible actuator control with group-level isolation. Electronic short-circuit protection with a 4-5 A threshold safeguards connected equipment. The wide DC 20-125 V output range accommodates diverse actuator types without additional interface components. Integrated diagnostics support proactive maintenance and rapid fault identification. Parallel output capability within the same group enables redundant load control for critical applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the output current rating of the 6ES7422-5EH10-0AB0?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e This module provides 1.5 A rated output current per channel, with a permitted range of 10 mA to 1.5 A and peak current up to 3 A for 10 ms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can two outputs be paralleled for higher current?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Yes, parallel connection of two outputs is supported for redundant load control and performance enhancement, but only within the same output group.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What fuse type does this module require?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e The module uses an 8 A \/ 250 V fast-acting replacement fuse. Always unplug the front connector before replacing the fuse.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67852951879812,"sku":"6ES7422-5EH10-0AB0","price":129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/6ES7422-5EH10-0AB0.jpg?v=1793530530","url":"https:\/\/www.etowonauto.com\/vi\/products\/siemens-6es7422-5eh10-0ab0-sm-422-do-16-module","provider":"Etowon Auto","version":"1.0","type":"link"}