{"product_id":"honeywell-fc-tsro-0824-sil3-safety-fta","title":"Honeywell FC-TSRO-0824 SIL3 Safety FTA","description":"\u003ch2\u003eSIL3 Safe Dry Digital Output FTA with 8 Relay Channels\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TSRO-0824\u003c\/strong\u003e and \u003cstrong\u003eFS-TSRO-0824\u003c\/strong\u003e provide eight potential-free relay outputs for SIL3 safety applications.\u003c\/p\u003e\n\u003ch2\u003eSafety Architecture\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for \u003cspan style=\"color: #b22222;\"\u003eSIL3 applications per IEC 61508\u003c\/span\u003e without requiring fault exclusions\u003c\/li\u003e\n\u003cli\u003eEight independent output channels with three relays per channel for high integrity\u003c\/li\u003e\n\u003cli\u003eEach channel includes fused normally open field contact and status indication LED\u003c\/li\u003e\n\u003cli\u003eCapable of switching 115\/230 V AC loads, providing AC output capability for Safety Manager\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eChannel Configuration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThree relays per output channel for redundant safety switching\u003c\/li\u003e\n\u003cli\u003eFused NO field contact rated at 5 A with slow-acting fuse\u003c\/li\u003e\n\u003cli\u003eLED indicator shows energized relay state for each channel\u003c\/li\u003e\n\u003cli\u003eScrew terminal interface for external field wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModels:\u003c\/strong\u003e \u003cstrong\u003eFC-TSRO-0824\u003c\/strong\u003e, \u003cstrong\u003eFS-TSRO-0824\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e \u003cspan style=\"color: #b22222;\"\u003eCE, UL, TUV, CSA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety class:\u003c\/strong\u003e Up to and including SIL3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage:\u003c\/strong\u003e 24 V DC nominal, 36 V DC max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay pick-up voltage:\u003c\/strong\u003e 19.2 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput current:\u003c\/strong\u003e 40 mA typical at 24 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOutput Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of channels:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax output current:\u003c\/strong\u003e 5 A (fused)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMin output current:\u003c\/strong\u003e 1 mA at 5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax output voltage:\u003c\/strong\u003e 250 V AC \/ 250 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax switched load:\u003c\/strong\u003e 1250 VA \/ 150 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelay Contact Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e250 V AC:\u003c\/strong\u003e 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 V DC:\u003c\/strong\u003e 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e48 V DC:\u003c\/strong\u003e 1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e110 V DC:\u003c\/strong\u003e 500 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax switching frequency:\u003c\/strong\u003e 20 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact material:\u003c\/strong\u003e Gold flash over silver alloy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFuse Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse rating:\u003c\/strong\u003e 5 A, 5x20 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage rating AC:\u003c\/strong\u003e 250 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage rating DC:\u003c\/strong\u003e 150 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schurter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer PN:\u003c\/strong\u003e 0001.2511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIsolation Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil to contact:\u003c\/strong\u003e 4000 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact to contact:\u003c\/strong\u003e 1200 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Dimensions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule dimensions:\u003c\/strong\u003e 300 × 70 × 60 mm (11.81 × 2.76 × 2.36 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN rail compatibility:\u003c\/strong\u003e TS32 \/ TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired rail length:\u003c\/strong\u003e 301 mm (11.85 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWiring Termination\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew terminals:\u003c\/strong\u003e Max wire diameter 2.5 mm² (AWG 14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip length:\u003c\/strong\u003e 7 mm (0.28 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening torque:\u003c\/strong\u003e 0.5 Nm (0.37 ft.-lb.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature:\u003c\/strong\u003e -5°C to +60°C (23°F to 140°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation \u0026amp; Packaging\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDIN rail mount with TS32\/TS35 compatibility\u003c\/li\u003e\n\u003cli\u003eIncludes module with screw terminals\u003c\/li\u003e\n\u003cli\u003eReady for field wiring termination\u003c\/li\u003e\n\u003cli\u003eShipping: FedEx, UPS, DHL worldwide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between FC-TSRO-0824 and FS-TSRO-0824?\u003c\/strong\u003e \u003cbr\u003eA: Both models provide identical SIL3 functionality. \u003cstrong\u003eFC-TSRO-0824\u003c\/strong\u003e includes conformal coating for harsh environments, while \u003cstrong\u003eFS-TSRO-0824\u003c\/strong\u003e is the standard version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can this module switch 230 V AC loads directly?\u003c\/strong\u003e \u003cbr\u003eA: Yes. The \u003cstrong\u003eTSRO-0824\u003c\/strong\u003e supports 250 V AC switching at up to 5 A, making it ideal for direct 115\/230 V AC load control in SIL3 applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Why does each channel use three relays?\u003c\/strong\u003e \u003cbr\u003eA: The three-relay configuration provides redundant safety paths and enables SIL3 compliance without fault exclusions. This architecture ensures safe de-energizing even if one relay fails.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51573245706372,"sku":"FC-TSRO-0824","price":611.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/FC-TSRO-0824_2.jpg?v=1772358336","url":"https:\/\/www.etowonauto.com\/vi\/products\/honeywell-fc-tsro-0824-sil3-safety-fta","provider":"Etowon Auto","version":"1.0","type":"link"}