{"product_id":"raio-01-abb-analog-extension-module-galvanic-isolation-1-5kv","title":"RAIO-01 ABB Analog Extension Module Galvanic Isolation 1.5kV","description":"\u003ch2 style=\"color: #0056b3; font-size: 1.5em;\"\u003eABB RAIO-01 I\/O Extension Module\u003c\/h2\u003e\n\u003cp style=\"font-size: 1.05em; line-height: 1.6;\"\u003eThe \u003cb style=\"color: #0056b3;\"\u003eABB RAIO-01\u003c\/b\u003e is an I\/O extension module designed for RMIO board option slots or external mounting via the AIMA-01 I\/O Adapter. Supporting bipolar (±0[4]-20 mA, ±0[2]-10 V, ±0-2 V) and unipolar (0[4]-20 mA) inputs, it delivers 12-bit output resolution with 0.024% accuracy. Featuring galvanic isolation and 1.5 kV AC chassis test voltage, this module ensures reliable signal integrity. Weighing 0.35 kg (0.77 lbs), it operates from -20°C to 60°C with IP20 protection.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 0.95em;\"\u003e\n\u003cthead style=\"background-color: #f2f4f6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eRAIO-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Extension Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eRMIO Board Option Slot or AIMA-01 I\/O Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInput Types\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBipolar (±0[4]-20 mA, ±0[2]-10 V, ±0-2 V), Unipolar (0[4]-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOutput Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eUnipolar Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e100 Ω (Current), 200 kΩ (Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOutput Resolution\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e12-bit (0.024% Accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eGalvanically Isolated (Inputs, Outputs, Carrier Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMax Isolation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e48 V RMS Continuous, 100 V Peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eChassis Isolation Test\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1.5 kV AC (1 second)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e100 mA (5 V), 120 mA (24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInaccuracy\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e±0.5% Full Scale @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e±100 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-20°C to 60°C (-4°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDimensions (H x D x W)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e16.5 x 11.5 x 0.004 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.35 kg (0.77 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eEstimated Lifetime\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e100,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eNode ID Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1-15 (Rotary Switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eInstallation \u0026amp; Field Application Guide\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eMount the 0.35 kg module in the RMIO board option slot or connect externally via the AIMA-01 I\/O Adapter.\u003c\/li\u003e\n\u003cli\u003eSet the Node ID (1-15) using the rotary switch before power-up.\u003c\/li\u003e\n\u003cli\u003eConfigure DIP switches for input signal mode (bipolar\/unipolar) and level selection.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cable for analog signals. Ground the shield at one end only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eWhy Choose the RAIO-01\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003e12-bit resolution with 0.024% accuracy delivers precise analog signal processing.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation protects the carrier board from field-side voltage transients.\u003c\/li\u003e\n\u003cli\u003eFlexible input configuration supports bipolar and unipolar signal types.\u003c\/li\u003e\n\u003cli\u003eDIP switches and rotary node ID simplify field configuration without software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eField Engineer FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ1:\u003c\/b\u003e What is the maximum isolation voltage of the RAIO-01?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA1:\u003c\/b\u003e The module provides 48 V RMS continuous and 100 V peak isolation. The chassis isolation test voltage is 1.5 kV AC for 1 second.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ2:\u003c\/b\u003e How do I set the input signal mode?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA2:\u003c\/b\u003e Use the DIP switches to select bipolar or unipolar input mode and the desired signal level.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ3:\u003c\/b\u003e What is the node ID range and how is it configured?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA3:\u003c\/b\u003e The node ID range is 1-15, configured via a rotary switch on the module.\u003c\/p\u003e\n\n\u003cp style=\"margin-top: 24px;\"\u003eInquiries: \u003ca style=\"color: #0056b3; text-decoration: none; font-weight: bold;\" href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047935606916,"sku":"RAIO-01","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/RAIO-01.jpg?v=1792829282","url":"https:\/\/www.etowonauto.com\/uz\/products\/raio-01-abb-analog-extension-module-galvanic-isolation-1-5kv","provider":"Etowon Auto","version":"1.0","type":"link"}