{"product_id":"positioner-v18345-1004210001-abb-4-20ma","title":"Positioner V18345-1004210001 ABB | 4-20mA","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eV18345-1004210001\u003c\/strong\u003e is an electro-pneumatic positioner from ABB, designed for precise valve control on linear and rotary actuators. Features 4–20 mA two-wire input, HART FSK communication, ATEX EEx nA II T6 protection, and fail-freeze output. Aluminum IP65\/NEMA 4X housing. Weight: 1.7 kg. Certified for SIL2 safety loops.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eV18345-1004210001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eElectro-Pneumatic Positioner (TZIDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA two-wire, max 25 mA \/ 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Input Current\u003c\/td\u003e\n\u003ctd\u003e3.4 mA (without feedback), start from 3.8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eHART 5.1, FSK module, LKS local connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eATEX EEx nA II T6 (Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput \/ Safe Position\u003c\/td\u003e\n\u003ctd\u003eFail freeze (single or double acting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0–6 bar (0–90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Pressure\u003c\/td\u003e\n\u003ctd\u003e1.4–6 bar (20–90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.03 kg\/h \/ 0.015 scfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Capacity (1.4 bar)\u003c\/td\u003e\n\u003ctd\u003e5.0 kg\/h = 3.9 Nm³\/h = 2.3 scfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Capacity (6 bar)\u003c\/td\u003e\n\u003ctd\u003e13 kg\/h = 10 Nm³\/h = 6.0 scfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Quality\u003c\/td\u003e\n\u003ctd\u003eDIN\/ISO 8573-1 Class 3 (5 µm, 5 mg\/m³, oil 1 mg\/m³)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAluminum, varnished, RAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ NEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Connections\u003c\/td\u003e\n\u003ctd\u003eG 1\/4 or 1\/4-18 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003e2 threads 1\/2-14 NPT or M20x1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003ctd\u003eMax 1.0 mm² (options) \/ 2.5 mm² (analog signal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input\u003c\/td\u003e\n\u003ctd\u003e24 V DC (12–30 V DC), max 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output\u003c\/td\u003e\n\u003ctd\u003e5–11 V DC (NAMUR DIN 19234)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Voltage (20 mA)\u003c\/td\u003e\n\u003ctd\u003e8.7 V DC (non-Ex) \/ 9.7 V DC (intrinsically safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (20 mA)\u003c\/td\u003e\n\u003ctd\u003e435 Ω (non-Ex) \/ 485 Ω (intrinsically safe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAngle of Rotation\u003c\/td\u003e\n\u003ctd\u003e25–120° (rotary, optional 270°); 25–60° (linear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTravel Limit\u003c\/td\u003e\n\u003ctd\u003e0–100%, min range \u0026gt;20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTravel Time Prolongation\u003c\/td\u003e\n\u003ctd\u003e0–200 seconds per direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharacteristic Deviation\u003c\/td\u003e\n\u003ctd\u003e≤0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTolerance Band\u003c\/td\u003e\n\u003ctd\u003e0.3–10% adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDead Band\u003c\/td\u003e\n\u003ctd\u003e0.1–10% adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;4000 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Rate\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Influence\u003c\/td\u003e\n\u003ctd\u003e≤0.5% per 10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Influence\u003c\/td\u003e\n\u003ctd\u003e≤±1% up to 10 g and 80 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeismic Compliance\u003c\/td\u003e\n\u003ctd\u003eDIN\/IEC 68-3-3 Class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (Operational)\u003c\/td\u003e\n\u003ctd\u003e95% annual average, condensation permissible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (Transport\/Storage)\u003c\/td\u003e\n\u003ctd\u003e75% annual average, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eSIL2 safety loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eATEX, FM, CSA, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eMount to linear actuators per DIN\/IEC 534\/NAMUR or rotary actuators per VDI\/VDE 3845. Integral mounting ready. Mechanical position indicator provides visual feedback. Mounting orientation has no effect on performance.\u003c\/p\u003e\n\u003ch3\u003eAir Supply\u003c\/h3\u003e\n\u003cp\u003eUse instrument air free of oil, water, and dust per DIN\/ISO 8573-1 Class 3: max particle 5 µm, density 5 mg\/m³, oil 1 mg\/m³, dew point 10 K below operating temperature. Do not exceed actuator max operating pressure.\u003c\/p\u003e\n\u003ch3\u003eHazardous Area Installation\u003c\/h3\u003e\n\u003cp\u003eATEX EEx nA II T6 (Zone 2) approved. Ambient temperature limits: T4 -40°C to +85°C, T5 -40°C to +65°C, T6 -40°C to +50°C. Also certified for FM\/CSA intrinsically safe and IECEx Ex ib IIC T6 applications.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eFail-Freeze Safety\u003c\/h3\u003e\n\u003cp\u003eOn electrical power failure, the actuator blocks in its last position (fail freeze). Ensures process continuity and safe operation in critical applications. Certified for SIL2 safety loops.\u003c\/p\u003e\n\u003ch3\u003eATEX Zone 2 Protection\u003c\/h3\u003e\n\u003cp\u003eATEX EEx nA II T6 certification enables installation in Zone 2 hazardous areas. Also certified for FM\/CSA intrinsically safe and IECEx Ex ib IIC T6 applications.\u003c\/p\u003e\n\u003ch3\u003ePrecise Valve Control\u003c\/h3\u003e\n\u003cp\u003eResolution \u0026gt;4000 steps with 20 ms sample rate. Characteristic deviation ≤0.5%. Freely configurable characteristic curves with 20 reference points. HART FSK communication for remote diagnostics.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the fail-safe behavior on electrical power failure?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e Fail freeze. The actuator blocks in its last position on loss of electrical power. Air is vented from the actuator or the actuator is blocked.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What explosion protection does this model provide?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e ATEX EEx nA II T6 (Zone 2). Also certified for FM\/CSA intrinsically safe and IECEx Ex ib IIC T6.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What communication protocol does this positioner use?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e HART 5.1 via FSK module over the 20 mA signal line. Also supports LKS local communication interface.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68134635405444,"sku":"V18345-1004210001","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/V18345-1004210001.jpg?v=1795526971","url":"https:\/\/www.etowonauto.com\/uz\/products\/positioner-v18345-1004210001-abb-4-20ma","provider":"Etowon Auto","version":"1.0","type":"link"}