{"product_id":"ge-369b1844g0019-analog-input-unit-4-20ma-10-10v","title":"GE 369B1844G0019 | Analog Input Unit 4-20mA -10-10V","description":"\u003ch2\u003eGE 369B1844G0019 Digital Output Card\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5f7a;\"\u003eGE 369B1844G0019\u003c\/strong\u003e is a digital output card designed for industrial control systems. It functions as an analog input (AI) unit that converts continuous analog signals from sensors (temperature, pressure, speed, flow, displacement) into digital signals for PLC processing. The module supports standard analog input levels including -10 to +10V, 0 to 10V, 1 to 5V voltage signals and 4 to 20mA current signals. Weight is 0.35 kg.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f4f7fa; border: 1px solid #b8c9d6;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #b8c9d6; color: #1a2a3a;\"\u003e\n\u003cth style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eGE Nexus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e369B1844G0019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eDigital Output Card \/ Analog Input Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eInput Voltage Signal Range\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e-10 to +10V, 0 to 10V, 1 to 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eInput Current Signal Range\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eSignal Processing\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eA\/D Conversion with Optical Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eInterface Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eI\/O Expansion Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eKey Components\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eSignal Processing, Multiplexer, A\/D Converter, Optocoupler Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli\u003eConverts analog sensor signals to digital data for PLC processing\u003c\/li\u003e\n\u003cli\u003eSupports voltage inputs: -10 to +10V, 0 to 10V, 1 to 5V\u003c\/li\u003e\n\u003cli\u003eSupports current inputs: 4 to 20mA\u003c\/li\u003e\n\u003cli\u003eIntegrated signal processing and multiplexing\u003c\/li\u003e\n\u003cli\u003eA\/D converter for high-precision digital conversion\u003c\/li\u003e\n\u003cli\u003eOptocoupler isolation for signal integrity and protection\u003c\/li\u003e\n\u003cli\u003eI\/O expansion interface for system scalability\u003c\/li\u003e\n\u003cli\u003eCompatible with GE XDPS-400e control system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe 369B1844G0019 analog input unit captures continuous analog signals from industrial sensors measuring temperature, pressure, speed, flow, and displacement. These signals are processed through signal conditioning, multiplexed via a multi-channel switch, converted to digital format by the A\/D converter, and isolated through optocouplers before being transmitted to the CPU. The I\/O expansion interface allows connection to additional I\/O units when system point counts exceed the main PLC capacity.\u003c\/p\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstall the module in the designated slot of the XDPS-400e rack. Ensure proper wiring for voltage or current inputs based on sensor output type. For current signals, ensure loop power is supplied externally. Use shielded cables for analog signals to minimize noise interference. Configure input range settings via system software prior to operation.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eQ1:\u003c\/strong\u003e What types of input signals does this module accept?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eA1:\u003c\/strong\u003e Voltage signals: -10 to +10V, 0 to 10V, 1 to 5V. Current signals: 4 to 20mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eQ2:\u003c\/strong\u003e What is the purpose of the I\/O expansion interface?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eA2:\u003c\/strong\u003e It allows connection of additional I\/O expansion units when the system requires more input\/output points than the main PLC provides.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eQ3:\u003c\/strong\u003e What isolation method is used on this module?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eA3:\u003c\/strong\u003e Optocoupler isolation is used to protect the CPU and maintain signal integrity between field devices and the control system.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52730379534468,"sku":"369B1844G0019","price":197.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/369B1844G0019.jpg?v=1788098909","url":"https:\/\/www.etowonauto.com\/uz\/products\/ge-369b1844g0019-analog-input-unit-4-20ma-10-10v","provider":"Etowon Auto","version":"1.0","type":"link"}