{"product_id":"3500-22m-01-01-00-bently-nevada-tdi-module-3500-22m","title":"3500\/22M-01-01-00 Bently Nevada TDI Module 3500\/22M","description":"\u003ch2\u003eBently Nevada 3500\/22M-01-01-00 TDI Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0066cc;\"\u003eBently Nevada 3500\/22M-01-01-00\u003c\/strong\u003e 3500\/22M Transient Data Interface (TDI) Module with 10Base-T\/100Base-TX Ethernet I\/O. Provides high-speed data communication between 3500 Machinery Protection System and host software. Supports BN Host Protocol and BN TDI Protocol for configuration, data acquisition, and System 1 integration. Total weight: 1.11 kg.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e10Base-T\/100Base-TX Ethernet I\/O (autosensing). BN Host Protocol and BN TDI Protocol support. Front panel USB-B port (115.2 kbaud). OK relay with arc suppressors (5A @ 24Vdc\/120Vac). Trip Multiply, Alarm Inhibit, and Rack Reset system contacts. 10.5W power consumption. Operating temperature -30°C to +65°C. 38 years battery life @ 50°C (powered).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3500\/22M-01-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3500\/22M TDI Module and I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDI Type (Option A)\u003c\/td\u003e\n\u003ctd\u003e01 = Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Type (Option B)\u003c\/td\u003e\n\u003ctd\u003e01 = 10Base-T\/100Base-TX Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval (Option C)\u003c\/td\u003e\n\u003ctd\u003e00 = None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Panel Communication\u003c\/td\u003e\n\u003ctd\u003eUSB-B (115.2 kbaud max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet I\/O\u003c\/td\u003e\n\u003ctd\u003e10Base-T\/100Base-TX, RJ-45, 100m max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols Supported\u003c\/td\u003e\n\u003ctd\u003eBN Host Protocol, BN TDI Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK Relay Rating\u003c\/td\u003e\n\u003ctd\u003e5A @ 24Vdc\/120Vac, 120W\/600VA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArc Protection\u003c\/td\u003e\n\u003ctd\u003eArc suppressors provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDI Module Dimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 x 24.4 x 241.8 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDI Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Weight\u003c\/td\u003e\n\u003ctd\u003e1.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space (TDI)\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space (I\/O)\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life (Powered)\u003c\/td\u003e\n\u003ctd\u003e38 years @ 50°C (122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life (Unpowered)\u003c\/td\u003e\n\u003ctd\u003e12 years @ 50°C (122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Code Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:01\u003c\/strong\u003e – Standard TDI for standard monitoring applications.\u003cbr\u003e\u003cstrong\u003eB:01\u003c\/strong\u003e – 10Base-T\/100Base-TX Ethernet I\/O module.\u003cbr\u003e\u003cstrong\u003eC:00\u003c\/strong\u003e – No agency approval.\u003c\/p\u003e\n\u003ch3\u003eSystem Contacts\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Multiply\u003c\/td\u003e\n\u003ctd\u003eDry contact to Common, \u0026lt;1mA, places rack in Trip Multiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Inhibit\u003c\/td\u003e\n\u003ctd\u003eDry contact to Common, \u0026lt;1mA, inhibits all alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Reset\u003c\/td\u003e\n\u003ctd\u003eDry contact to Common, \u0026lt;1mA, clears latched alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstall TDI module in full-height front slot (Slot 1, next to power supplies). Install I\/O module in corresponding full-height rear slot. Connect Ethernet via RJ-45 (100m max). Use USB-B cable (5m max) for local configuration. Configure OK relay contact (OPEN\/CLOSED) for NOT OK annunciation. When upgrading from RIM, remove RIM and RIM I\/O before installing TDI I\/O and TDI.\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eProvides high-speed data extraction for condition monitoring and diagnostics. Dual protocol support (BN Host and BN TDI) ensures compatibility with 3500 Configuration Software and System 1. Ethernet connectivity enables remote monitoring and configuration. System contacts (Trip Multiply, Alarm Inhibit, Rack Reset) provide external control. Long battery life preserves configuration during power loss.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What protocols does the 3500\/22M support?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e BN Host Protocol (Configuration, Data Acquisition, Display Software) and BN TDI Protocol (System 1 Condition Monitoring).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the maximum Ethernet cable length?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e 100 metres (328 feet) for 10Base-T\/100Base-TX.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the function of the OK relay?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e Indicates normal rack operation or fault detection. User-selectable OPEN or CLOSED contact for NOT OK condition. Normally Energized operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050451501188,"sku":"3500\/22M-01-01-00","price":295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500-22-2_09f94ba6-e4be-4371-82d1-eeef1d703c96.jpg?v=1787495451","url":"https:\/\/www.etowonauto.com\/uz\/products\/3500-22m-01-01-00-bently-nevada-tdi-module-3500-22m","provider":"Etowon Auto","version":"1.0","type":"link"}