{"product_id":"1762-ov32t-allen-bradley-32-point-sinking-output-module","title":"1762-OV32T Allen-Bradley 32 Point Sinking Output Module","description":"\u003ch2\u003eAllen-Bradley 1762-OV32T MicroLogix 1200 Output Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0066cc;\"\u003eAllen-Bradley 1762-OV32T\u003c\/strong\u003e | MicroLogix 1200 solid-state sinking output module with 32 outputs. Converts digital signals from the PLC CPU into output signals for field devices. Designed for DIN rail mounting in IP20 general purpose enclosures. Weight: approximately 200 g (7.05 oz).\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e32 sinking outputs. Solid-state output design. 24VDC sink input power. Operating voltage range 10.2-26.4VDC. Maximum bus current draw 175 mA at 5VDC. Heat dissipation 2.7 kW at 26.4VDC. DIN rail mounting. IP20 general purpose enclosure required. Operates up to 2000 m altitude without derating. 95% maximum relative humidity. 50.8 mm clearance required on each side for ventilation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1762-OV32T\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1200\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOutput Module\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e32 (Sinking)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSolid-State Sink\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e24V DC Sink\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10.2-26.4V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBus Current Draw\u003c\/td\u003e\n\u003ctd\u003e175 mA at 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.7 kW at 26.4V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 (general purpose)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMaximum Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m (6562 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% max\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C (-4°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e90 x 40.4 x 87 mm (3.54 x 1.59 x 3.43 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 200 g (7.05 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e10612598849915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMount on DIN rail inside IP20 general purpose enclosure. Leave 50.8 mm (2 in) clearance on each side for proper ventilation. Connect the terminal to a grounding system to limit electrical noise. Ensure operating temperature remains between -20°C and +60°C. The enclosure protects against dust (pollution degree 2) but not against liquids or ice formation.\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e32 outputs in a compact single-slot module maximize channel density. Solid-state sinking outputs provide fast switching and long service life without mechanical wear. Wide 10.2-26.4VDC operating range accommodates supply variations. Low 175 mA bus current draw preserves backplane power budget. DIN rail mounting simplifies installation and replacement. Operates up to 2000 m altitude without derating.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e How many outputs does this module provide?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e 32 sinking outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the operating voltage range?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e 10.2-26.4V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What enclosure type is required?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e An IP20 general purpose enclosure with pollution degree 2 rating.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67640898224260,"sku":"1762-OV32T","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1762-OV32T.jpg?v=1792937433","url":"https:\/\/www.etowonauto.com\/uz\/products\/1762-ov32t-allen-bradley-32-point-sinking-output-module","provider":"Etowon Auto","version":"1.0","type":"link"}