{"product_id":"tsxdmz28ar-schneider-electric-28-point-relay-discrete-base","title":"TSXDMZ28AR Schneider Electric 28 Point Relay Discrete Base","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eTSXDMZ28AR\u003c\/strong\u003e is a discrete relay I\/O base module engineered by Schneider Electric for the Modicon TSX Micro automation platform. Designed for industrial process control, this module integrates 28 total channels comprising 16 AC discrete inputs (100–120 V AC) and 12 Normally Open (NO) relay outputs. Equipped with screw terminal blocks and certified to IEC 1131-2 Type 2 standards, the TSXDMZ28AR provides high isolation between field circuits and logic controls. Weighing 0.5 kg (1.1 lb) in a compact housing, it mounts directly onto standard DIN rails in control cabinets.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCombined High-Density I\/O:\u003c\/strong\u003e Integrates 16 AC inputs and 12 relay outputs into a single Modicon TSX Micro slot base.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Relay Output Ratings:\u003c\/strong\u003e Supports switching loads up to 264 V AC and 34 V DC with a 3 A conventional thermal current (Ith).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Electrical Isolation:\u003c\/strong\u003e Provides 1500 V isolation for 1 second with an insulation resistance of ≥ 10 MΩ.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eBrand \u0026amp; Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Line Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eModicon TSX Micro Automation Platform\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eTSXDMZ28AR\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eEAN Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e3389110540444\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Function Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDiscrete Relay I\/O Base Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eTotal I\/O Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e28 Channels (16 Inputs \/ 12 Relay Outputs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eDiscrete Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e100...120 V AC (47...63 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eDiscrete Input Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e11 mA at 50 Hz \/ 13 mA at 60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eInput Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eState 1: ≥ 74 V \/ State 0: \u0026lt; 20 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOutput Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e19...264 V AC \/ 10...34 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOutput Contact Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eNormally Open (NO) Contacts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eThermal Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e3 A conventional free air thermal current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5.6 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1500 V AC for 1 s \/ 500 V AC continuous\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e35 mm DIN Rail Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIEC 1131-2 Type 2; CE, UL, CSA Certified\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating Ambient Thermal Scope\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eStorage Thermal Scope\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-40°C to +85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.5 kg (1.1 lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachinery Control Automation:\u003c\/strong\u003e Interfaces 110V limit switches and control pushbuttons to TSX Micro PLCs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess Actuator Driving:\u003c\/strong\u003e Operates small solenoids, contactors, and indicator lamps via NO relay contacts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHVAC \u0026amp; Facility Monitoring:\u003c\/strong\u003e Controls auxiliary pumps, dampers, and status feedback loops in plant panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWiring \u0026amp; Installation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Snap the TSXDMZ28AR onto the TSX Micro rack or DIN rail until the locking clip engages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Terminal Wiring:\u003c\/strong\u003e Connect 100–120 V AC inputs and relay load wiring directly to the screw terminal block.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e Wire 2-wire proximity switches directly to input terminals observing voltage limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Load Capacity:\u003c\/strong\u003e Relay contacts switch up to 220 VA AC resistive\/inductive and 40 W 24V DC loads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Thermal Endurance:\u003c\/strong\u003e Operates continuously from -25°C to +70°C in demanding panel environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e Weighs only 0.5 kg to streamline backplate load distribution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What input voltage rating does the Schneider TSXDMZ28AR module support?\u003c\/strong\u003e\u003cbr\u003e\nA1: The module features 16 discrete input channels rated for 100...120 V AC at 47...63 Hz.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum continuous current capacity for the relay outputs?\u003c\/strong\u003e\u003cbr\u003e\nA2: The NO relay outputs support a conventional free air thermal current (Ith) of 3 A per channel.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Is the TSXDMZ28AR compatible with 2-wire proximity sensors?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes, the input circuitry is fully compatible with 2-wire AC proximity sensors.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67623771635844,"sku":"TSXDMZ28AR","price":176.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/TSXDMZ28AR.jpg?v=1792586747","url":"https:\/\/www.etowonauto.com\/tr\/products\/tsxdmz28ar-schneider-electric-28-point-relay-discrete-base","provider":"Etowon Auto","version":"1.0","type":"link"}