{"product_id":"schneider-bmenop0300c-m580-iec-61850-module-atex-zone-2","title":"Schneider BMENOP0300C M580 IEC 61850 Module ATEX Zone 2","description":"\u003ch2 style=\"color: #1a1a1a;\"\u003eSchneider Electric BMENOP0300C Modicon M580 Communication Module\u003c\/h2\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cstrong style=\"color: #0066b3;\"\u003eSchneider Electric BMENOP0300C\u003c\/strong\u003e is a Modicon M580 communication module with IEC 61850 support. Features 3 x Ethernet 10\/100BASE-TX ports, MMS messaging client\/server, GOOSE, and Modbus TCP messaging. Conformal coated with ATEX Zone 2\/22 certification.\u003c\/p\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eModicon M580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eM580 PAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e3 x Ethernet 10\/100BASE-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1250 mA at 3.3V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0.24 kg (0.53 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003eCommunication Services\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 20px;\"\u003e\n\u003cli\u003eMMS messaging client IEC 61850\u003c\/li\u003e\n\u003cli\u003eMMS messaging server IEC 61850\u003c\/li\u003e\n\u003cli\u003eGOOSE IEC 61850\u003c\/li\u003e\n\u003cli\u003eModbus TCP messaging\u003c\/li\u003e\n\u003cli\u003eRSTP support\u003c\/li\u003e\n\u003cli\u003eIP forwarding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003eCertifications\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 20px;\"\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eMerchant Navy\u003c\/li\u003e\n\u003cli\u003eATEX Zone 2\/22\u003c\/li\u003e\n\u003cli\u003eIECEx Zone 2\/22\u003c\/li\u003e\n\u003cli\u003eHazardous Location Class I Division 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003eEnvironmental Resistance\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eGas Resistance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eClass Gx ISA S71.04 \/ Class 3C4 IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eDust Resistance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eClass 3S4 IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSalt Resistance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eLevel 2 IEC 68252\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMold\/Fungal Resistance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eClass 3B2 IEC 60721-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0°C to +60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eUp to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003eStandards\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 20px;\"\u003e\n\u003cli\u003eEN\/IEC 61131-2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201\u003c\/li\u003e\n\u003cli\u003eIACS E10\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 61000-6-5 interface type 1 and type 2\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 61850-3 location G\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60079-0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What IEC 61850 services does this module support?\u003c\/strong\u003e\u003cbr\u003eA1: MMS messaging client\/server and GOOSE.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What hazardous area certifications does it have?\u003c\/strong\u003e\u003cbr\u003eA2: ATEX Zone 2\/22, IECEx Zone 2\/22, and Class I Division 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the current consumption?\u003c\/strong\u003e\u003cbr\u003eA3: 1250 mA at 3.3V DC.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67761152983172,"sku":"BMENOP0300C","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/BMEP584040_fbb31b39-ed0a-47db-a8ec-3bd9b9b04faa.jpg?v=1793198783","url":"https:\/\/www.etowonauto.com\/tr\/products\/schneider-bmenop0300c-m580-iec-61850-module-atex-zone-2","provider":"Etowon Auto","version":"1.0","type":"link"}