{"product_id":"abb-ss832-voting-unit-3bsc610068r1-24v-10a-redundant","title":"ABB SS832 Voting Unit 3BSC610068R1 24V 10A Redundant","description":"\u003ch2\u003eABB 3BSC610068R1 SS832 Voting Unit\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5f7a;\"\u003eABB 3BSC610068R1\u003c\/strong\u003e (SS832 Voting Unit) is a redundant power supply control unit designed for critical industrial applications. It accepts two 24 Vdc inputs from redundant power supplies, supervises output voltage, and generates supervision signals. The unit features front-panel green LEDs for visual status indication and a voltage-free OK contact. Weight is 350 g (0.77 lbs).\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f4f7fa; border: 1px solid #b8c9d6;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #b8c9d6; color: #1a2a3a;\"\u003e\n\u003cth style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eSS832\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eArticle Number\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e3BSC610068R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eVoting Unit \/ Redundant Power Supply Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e2 x 24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eRated Input Power\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e2 x 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eRated Output Current\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e10 A (20 A in parallel operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e25 A (Overload)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eOutput Voltage Regulation\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e0.85 V typ. at max current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e18 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eSupervision Relay\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eMaximum Ambient Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eIEC 61131-2, UL 508, EN 50178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eEMC\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eMarine Certification\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eDIRECTIVE\/2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eDIRECTIVE\/2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e32 x 125 x 117 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px; border: 1px solid #8ba3b0;\"\u003e350 g (0.77 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli\u003eRedundant power supply voting and supervision\u003c\/li\u003e\n\u003cli\u003eTwo 24 Vdc inputs with automatic output selection\u003c\/li\u003e\n\u003cli\u003eGreen LED status indicators for each input channel\u003c\/li\u003e\n\u003cli\u003eVoltage-free OK contact for supervision signaling\u003c\/li\u003e\n\u003cli\u003e10 A rated output (20 A parallel operation)\u003c\/li\u003e\n\u003cli\u003e25 A maximum overload capacity\u003c\/li\u003e\n\u003cli\u003eClass I equipment with protective earth connection\u003c\/li\u003e\n\u003cli\u003eSELV and PELV application accepted\u003c\/li\u003e\n\u003cli\u003eOver-current and over-voltage protection\u003c\/li\u003e\n\u003cli\u003eSimple DIN-rail mounting\u003c\/li\u003e\n\u003cli\u003eMarine certified (ABS, BV, DNV-GL, LR)\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMount the unit on standard DIN rail. Connect two 24 Vdc power supply outputs to the voting unit inputs. Connect the output to the load. Ensure protective earth (PE) connection for Class I equipment. Observe minimum mounting spacing of 15 mm (W) and 25 mm (H) for proper airflow.\u003c\/p\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eQ1:\u003c\/strong\u003e What is the maximum output current of the 3BSC610068R1?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eA1:\u003c\/strong\u003e 10 A rated, 20 A in parallel operation, with 25 A overload capacity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eQ2:\u003c\/strong\u003e What certifications does this unit carry?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eA2:\u003c\/strong\u003e Marine certifications (ABS, BV, DNV-GL, LR), IEC 61131-2, UL 508, EN 50178, CE, RoHS, WEEE.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eQ3:\u003c\/strong\u003e What does the green LED indicate?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #1a5f7a;\"\u003eA3:\u003c\/strong\u003e Green LED indicates correct output voltage is being delivered. The OK contact closes simultaneously.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52581202198660,"sku":"3BSC610068R1","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/SS8323BSC610068R1.jpg?v=1785937096","url":"https:\/\/www.etowonauto.com\/tr\/products\/abb-ss832-voting-unit-3bsc610068r1-24v-10a-redundant","provider":"Etowon Auto","version":"1.0","type":"link"}