{"product_id":"330905-05-10-05-12-05-bently-nevada-nsv-proximity-probe","title":"330905-05-10-05-12-05 Bently Nevada NSv Proximity Probe","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada 330905-05-10-05-12-05\u003c\/strong\u003e is an industrial-grade 3300 NSv (Narrow Side View) proximity probe engineered for tight-clearance shaft vibration and position measurements on rotating machinery. Designed for applications where standard 8 mm probes cannot fit, this precision eddy current transducer features an M10x1 metric thread and delivers highly linear displacement measurements across a 0 to 2.5 mm (0 to 100 mils) operating range.\u003c\/p\u003e\n\n\u003cp\u003eBuilt with a 50.0 mm unthreaded section, a 100.0 mm overall case length, and a 0.5-meter oil-resistant FluidLoc cable, this lightweight module weighs approximately \u003cstrong\u003e0.15 kg (0.33 lbs)\u003c\/strong\u003e for minimal structural loading. It carries IP68 submersion protection, 20g peak vibration resistance, and comprehensive hazardous area certifications including ATEX, IECEx, and CSA Class I, Div 2.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNarrow Clearance Design:\u003c\/strong\u003e Tailored for tight mounting spaces, providing precision eddy current measurement where standard 8 mm probes are physically constrained.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFluidLoc Cable Protection:\u003c\/strong\u003e Features an integrated 0.5m oil-resistant FluidLoc cable that prevents oil and process fluids from leaking through the cable interior into control cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP68 Submersion \u0026amp; High Vibration Resistance:\u003c\/strong\u003e Rated for continuous immersion (1m \/ 30min) and engineered to endure extreme 20g peak random vibration from 10 to 2,000 Hz.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Hazardous Area Approvals:\u003c\/strong\u003e Fully certified under ATEX (Ex ia IIC T4), IECEx, and CSA Class I Div 2 for compliant installation in explosive environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eFull Configuration Code\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e330905-05-10-05-12-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eProduct Line\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e3300 NSv Industrial Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eThread Size \u0026amp; Class\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eM10x1 (ISO 965-1 Class 6H Tolerance)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eUnthreaded Case Length (-05)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e50.0 mm ±0.08 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eOverall Case Length (-10)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e100.0 mm (+0.2\/-0.1 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eTotal Cable Length (-05)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.5 meter (1.6 feet) FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eNet Unit Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.15 kg (0.33 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eMeasurement Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0 - 2.5 mm (0 - 100 mils) ±1.5% FSO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDC to 15 kHz (+1\/-3 dB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003ePower Requirements\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-18 to -26 VDC @ 4 to 12 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-40°C to +150°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eEnvironmental Sealing\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIP68 (1m \/ 30 min submersion)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eVibration Resistance\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e20g Peak (10 - 2,000 Hz random)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eAgency Certifications\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eATEX II 2G Ex ia IIC T4, IECEx, CSA Class I Div 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Gap Calibration Guide\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting \u0026amp; Torque:\u003c\/strong\u003e Thread the M10x1 casing into the probe port and tighten to 15 N·m ±10% dry torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Setting:\u003c\/strong\u003e Adjust probe depth until the Proximitor output reaches the pre-set gap voltage of -10V ±0.25V DC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e Secure the FluidLoc cable clear of moving components, preserving a clean bend radius.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What does configuration 330905-05-10-05-12-05 stand for?\u003c\/strong\u003e\u003cbr\u003e\nA1: 3300 NSv M10x1 probe, 50mm unthreaded, 100mm case, 0.5m cable, ClickLoc connector, ATEX\/IECEx\/CSA. (95 chars)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: When should I choose a 3300 NSv probe over an 8 mm probe?\u003c\/strong\u003e\u003cbr\u003e\nA2: Choose NSv probes for narrow side view installations with limited side clearance or small shafts. (95 chars)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What benefit does the FluidLoc cable provide?\u003c\/strong\u003e\u003cbr\u003e\nA3: It prevents oil and process liquids from wicking through the inside of the cable assembly. (87 chars)\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047891730564,"sku":"330905-05-10-05-12-05","price":184.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330905-05-10-05-12-05.jpg?v=1785503038","url":"https:\/\/www.etowonauto.com\/tr\/products\/330905-05-10-05-12-05-bently-nevada-nsv-proximity-probe","provider":"Etowon Auto","version":"1.0","type":"link"}