{"product_id":"1734-fpd-allen-bradley-point-i-o-250v-continuous-isolation-unit","title":"1734-FPD Allen-Bradley POINT I\/O 250V Continuous Isolation Unit","description":"\u003ch2 style=\"color: #003366; font-weight: bold; margin-bottom: 12px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333;\"\u003eThe \u003cstrong style=\"color: #003366;\"\u003eAllen-Bradley 1734-FPD\u003c\/strong\u003e is a specialized field-side voltage distribution module designed for the POINT I\/O 1734 system platform. Engineered to partition field power distribution within a backplane assembly, this module allows control systems to cleanly isolate and pass different field power bus voltages across I\/O segments. Supporting flexible input ratings of 12\/24V DC (10–28.8V DC working range) and 120\/240V AC, it delivers up to a 10A field power supply current without consuming power or causing thermal dissipation. Built into an open-style compact housing with a net weight of \u003cstrong style=\"color: #003366;\"\u003e0.12 kg (0.26 lbs)\u003c\/strong\u003e, the 1734-FPD integrates seamlessly into EtherNet\/IP, ControlNet, and DeviceNet architectures via standard POINT I\/O adapters.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eKey Advantages\u003c\/h2\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; padding-left: 20px; margin-bottom: 15px;\"\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eField Power Bus Isolation:\u003c\/strong\u003e Safely partitions distinct field power voltage domains across a single POINT I\/O rail backplane.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eDual AC\/DC Input Capability:\u003c\/strong\u003e Compatible with 12\/24V DC and 120\/240V AC voltage sources for maximum installation flexibility.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eZero Power Dissipation:\u003c\/strong\u003e Efficient passive pass-through design generates no internal power consumption or operational heat build-up.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eRobust Isolation Rating:\u003c\/strong\u003e Provides 250V continuous isolation voltage tested at 2600V DC for 60 seconds to safeguard sensitive backplane electronics.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eFlexible Mounting \u0026amp; Compact Footprint:\u003c\/strong\u003e Supports horizontal or vertical DIN rail mounting in tight control cabinets with a net weight of 0.12 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #003366; font-size: 14px; color: #333333;\"\u003e\n    \u003ctbody\u003e\n        \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; width: 35%;\"\u003eManufacturer \/ Brand\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eProduct Series\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003ePOINT I\/O (1734 Series)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold;\"\u003eCatalog \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e1734-FPD\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eModule Type\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eField Power Distributor Module\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold;\"\u003ePower Supply Input\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e12\/24V DC or 120\/240V AC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eDC Operating Voltage Range\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e10.0V DC to 28.8V DC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold;\"\u003eField Power Bus Current\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e10 Amperes Max\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eContinuous Isolation Voltage\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e250V Continuous (Tested @ 2600V DC for 60s)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold;\"\u003ePower \/ Thermal Dissipation\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e0 W (None)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eEstimated Net Weight\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e\u003cstrong style=\"color: #003366;\"\u003e0.12 kg (0.26 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e76.2 mm x 25.4 mm x 133.4 mm (3.0 x 1.0 x 5.25 in)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eWire Size \u0026amp; Terminal Torque\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e0.25–2.5 mm² (22–14 AWG); 0.6 Nm (7 lb-in)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eEnclosure \u0026amp; Mounting\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eOpen-style; Horizontal or Vertical DIN Rail\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ1: What is the primary role of the Allen-Bradley 1734-FPD module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA1: It acts as a field power distributor to isolate or break field voltage domains on a POINT I\/O bus.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ2: What input voltages and currents does the 1734-FPD support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA2: Supports 12\/24V DC or 120\/240V AC inputs with up to 10A field power supply current.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ3: How much does the Allen-Bradley 1734-FPD module weigh?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA3: The net weight of the module is 0.12 kg (0.26 lbs).\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52779604508804,"sku":"1734-FPD","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1734-FPD_3.jpg?v=1789218666","url":"https:\/\/www.etowonauto.com\/tr\/products\/1734-fpd-allen-bradley-point-i-o-250v-continuous-isolation-unit","provider":"Etowon Auto","version":"1.0","type":"link"}