{"product_id":"v18345-2010420001-abb-tzidc-positioner-double-acting","title":"V18345-2010420001 ABB TZIDC Positioner Double Acting","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eV18345-2010420001\u003c\/strong\u003e is a TZIDC electro-pneumatic positioner from ABB, designed for precise valve control on linear and rotary actuators. Features 4–20 mA two-wire input, HART 5.1 communication, and double-acting fail-safe output. Aluminum housing with IP65\/NEMA 4X protection. Weight: 1.7 kg.\u003c\/p\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3\u003eControl Characteristics\u003c\/h3\u003e\n\u003cp\u003eSignal 4–20 mA corresponds to actuator position 0–100%. Characteristic curve: linear, equal percentage 1:25\/1:50 or 25:1\/50:1, freely configurable with 20 reference points. Characteristic deviation \u0026lt;0.5%. Dead band 0.1–10% adjustable. Resolution \u0026gt;4000 steps, sample rate 20 ms.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eV18345-2010420001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eTZIDC Electro-Pneumatic Positioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA (two-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eHART 5.1, LKS local connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput \/ Safe Position\u003c\/td\u003e\n\u003ctd\u003eDouble acting, fail safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Pressure\u003c\/td\u003e\n\u003ctd\u003e1.4–6 bar (20–90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.03 kg\/h \/ 0.015 scfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Quality\u003c\/td\u003e\n\u003ctd\u003eDIN\/ISO 8573-1 Class 3 (5 µm, 5 mg\/m³, oil 1 mg\/m³)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAluminum, varnished, RAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ NEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Connections\u003c\/td\u003e\n\u003ctd\u003eG 1\/4 or 1\/4-18 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003eCable: 1\/2-14 NPT; Air pipe: 1\/4-18 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input\u003c\/td\u003e\n\u003ctd\u003e0–5 V DC (logical 0), 11–30 V DC (logical 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output\u003c\/td\u003e\n\u003ctd\u003e5–11 V DC (NAMUR DIN 19234)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharacteristic Deviation\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTolerance Band\u003c\/td\u003e\n\u003ctd\u003e0.3–10% adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDead Band\u003c\/td\u003e\n\u003ctd\u003e0.1–10% adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;4000 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Rate\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Influence\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.5% per 10 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Influence\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;±1% to 10 g and 80 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeismic Compliance\u003c\/td\u003e\n\u003ctd\u003eDIN\/IEC 68-3-3 Class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Directive\u003c\/td\u003e\n\u003ctd\u003e89\/336\/EWG, CE marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eMount to linear actuators per DIN\/IEC 534\/NAMUR or rotary actuators per VDI\/VDE 3845. Mechanical position indicator provides visual feedback. Mounting orientation has no measurable influence on performance.\u003c\/p\u003e\n\u003ch3\u003eAir Supply\u003c\/h3\u003e\n\u003cp\u003eUse instrument air free of oil, water, and dust per DIN\/ISO 8573-1 Class 3: max particle size 5 µm, max density 5 mg\/m³, oil content 1 mg\/m³, pressure dew point 10 K below operating temperature. Do not exceed actuator max operating pressure.\u003c\/p\u003e\n\u003ch3\u003eElectrical Connection\u003c\/h3\u003e\n\u003cp\u003eConnect 4–20 mA two-wire signal. HART communication via 20 mA signal line with optional FSK modem. LKS adapter connects to local communication interface. Cable entry: 1\/2-14 NPT.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003ePrecise Valve Control\u003c\/h3\u003e\n\u003cp\u003eResolution \u0026gt;4000 steps with 20 ms sample rate ensures accurate positioning. Characteristic deviation \u0026lt;0.5% and adjustable dead band (0.1–10%) provide fine control for demanding process applications.\u003c\/p\u003e\n\u003ch3\u003eRobust Environmental Protection\u003c\/h3\u003e\n\u003cp\u003eIP65\/NEMA 4X aluminum housing with electrostatic epoxy varnish resists corrosion and dust. Withstands vibration to 10 g at 80 Hz and meets DIN\/IEC 68-3-3 Class III seismic requirements.\u003c\/p\u003e\n\u003ch3\u003eFlexible Configuration\u003c\/h3\u003e\n\u003cp\u003eLinear, equal percentage, or freely configurable characteristic curves with 20 reference points. HART 5.1 communication enables remote diagnostics and configuration. Double-acting fail-safe output ensures safe valve position on power loss.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the supply pressure range for this positioner?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e 1.4–6 bar (20–90 psi). Do not exceed the maximum operating pressure of the actuator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What communication protocol does the TZIDC support?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e HART 5.1 via 20 mA signal line with optional FSK modem. Also supports LKS local communication adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the fail-safe behavior on electrical power failure?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e The 4 suffix indicates double-acting, fail-safe output. The actuator moves to its safe position on loss of electrical power.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68134049677444,"sku":"V18345-2010420001","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/V18345-2010420001.jpg?v=1795525017","url":"https:\/\/www.etowonauto.com\/tk\/products\/v18345-2010420001-abb-tzidc-positioner-double-acting","provider":"Etowon Auto","version":"1.0","type":"link"}