{"product_id":"schneider-bmecxm0100-x80-canopen-module-63-servers","title":"Schneider BMECXM0100 | X80 CANopen Module | 63 Servers","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eSchneider BMECXM0100\u003c\/strong\u003e is a CANopen communication module for the Modicon X80 platform. It connects M580 PLCs to open industrial fieldbus networks via a DB9 physical interface. Weighing 180 g, this standard-format module supports up to 63 server devices and delivers transmission rates from 20 kbit\/s to 1 Mbit\/s. It suits distributed control architectures requiring reliable fieldbus communication.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThis module uses CSMA\/CA CANopen access methods with NRZ transmission mode over CANopen twisted shielded pairs cable. Transmission distance varies by rate: 2500 m at 20 kbit\/s, 1000 m at 50 kbit\/s, 500 m at 125 kbit\/s, 250 m at 250 kbit\/s, 100 m at 500 kbit\/s, and 20 m at 1 Mbit\/s. Communication service complies with CiA DSP 301 V4.02. The module draws 100 mA from 24V DC internal supply.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange of Product\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModicon X80\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBMECXM0100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCANopen communication module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Compatibility\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eM580 PLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhysical Interface\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDB9 connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMethod of Access\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCSMA\/CA CANopen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMode of Transmission\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNRZ\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTransmission Medium\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCANopen twisted shielded pairs cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTransmission Rate\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e20 kbit\/s (2500 m) to 1 Mbit\/s (20 m)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNumber of Server Devices\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e63\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommunication Service\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCiA DSP 301 V4.02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRated Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC internal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCurrent Consumption\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e100 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModule Format\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStandard\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0…60 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-45…85 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e10…95 % without condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Altitude\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e≤ 2000 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e180 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDirectives\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2014\/35\/EU, 2014\/30\/EU\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eMount the module in a standard Modicon X80 rack slot compatible with M580 PLC systems. Connect the DB9 interface to the CANopen twisted shielded pairs cable. Select the transmission rate based on bus length requirements, from 2500 m at 20 kbit\/s to 20 m at 1 Mbit\/s. Use repeaters for distances exceeding standard limits at higher rates. Maintain operating altitude below 2000 m and humidity between 10% and 95% without condensation.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThis module connects M580 PLCs to CANopen networks supporting up to 63 server devices, enabling large distributed I\/O architectures. The DB9 interface simplifies field wiring with standard CANopen cabling. Flexible transmission rates from 20 kbit\/s to 1 Mbit\/s suit varied network topologies and distances. Compliance with CiA DSP 301 V4.02 ensures interoperability with third-party CANopen devices. The 180 g compact format preserves rack space in dense installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many server devices does the BMECXM0100 support?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e This CANopen module supports up to 63 server devices on a single network segment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What transmission rates and distances does the module offer?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e It supports 20 kbit\/s at 2500 m with repeater, 50 kbit\/s at 1000 m, 125 kbit\/s at 500 m, 250 kbit\/s at 250 m, 500 kbit\/s at 100 m without repeater, and 1 Mbit\/s at 20 m without repeater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Which PLC systems is this module compatible with?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e The BMECXM0100 is compatible with M580 PLC systems in the Modicon X80 range.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67750700187780,"sku":"BMECXM0100","price":167.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/BMECXM0100-1.jpg?v=1793281726","url":"https:\/\/www.etowonauto.com\/tk\/products\/schneider-bmecxm0100-x80-canopen-module-63-servers","provider":"Etowon Auto","version":"1.0","type":"link"}