{"product_id":"rint-5611c-main-circuit-connection-module-abb-drives","title":"RINT-5611C Main Circuit Connection Module ABB Drives","description":"\u003ch2 style=\"color: #1A237E; font-size: 22px; font-weight: bold; margin-bottom: 12px;\"\u003eABB RINT-5611C Main Circuit Interface Board\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px;\"\u003e\n  The \u003cstrong style=\"color: #0D47A1;\"\u003e\u003cspan style=\"color: #0D47A1;\"\u003eABB RINT-5611C\u003c\/span\u003e\u003c\/strong\u003e (Product ID: 68718929) is a vital main circuit interface option board kit engineered specifically for the ABB ACS800 series variable frequency drives (VFDs). Weighing 1.0 kg, this high-performance circuit board acts as the primary hardware link between the high-power inverter switching components and the low-voltage processing control electronics.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eKey Advantages\u003c\/h3\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCritical Signal Routing:\u003c\/strong\u003e Safely processes core analog metrics, timing signals, and feedback loops between the drive’s power sections and the control processor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplete Option Kit:\u003c\/strong\u003e Supplied as a certified factory kit (including required internal fan allocations for specific R6 frame configurations) to minimize asset downtime.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e Engineered to withstand the intensive thermal and electromagnetic interference (EMI) profiles typical of industrial drive cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 13px; color: #333333; margin-bottom: 15px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0; width: 40%;\"\u003eProduct Identifiers\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eProduct ID: 68718929 \/ Model: RINT-5611C (MAIN CIRC.INT. SP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eABB ACS800 Series Inverters (Optimized for ACS800-01\/04 R6 Frame Drives)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eVoltage Application Scope\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e380 V to 500 V Power Drive Interface Environments\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003ePhysical Dimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e365 mm (W) x 90 mm (H) x 290 mm (D\/L)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eWeight Profile\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eNet Component Weight: 1.0 kg \/ Gross Package Weight: 1.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eCustoms Tariff Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e85049090 (Inverter Spare Parts Classification)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eQuick Installation\u003c\/h3\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplete Power Lockout:\u003c\/strong\u003e Isolate the VFD system from upstream feeders. Wait at least 5 to 15 minutes for the DC bus capacitors to discharge safely before servicing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatic Protection:\u003c\/strong\u003e Use a calibrated ESD grounding wrist strap when handling the 1.0 kg bare PCB board to prevent micro-circuit punctures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFan Replacement Note:\u003c\/strong\u003e For specific ACS800 R6 IP21 modules, ensure the companion internal cooling fan provided in the maintenance kit is replaced along with the board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ1: What is the exact function of the RINT-5611C board within the ACS800 system?\u003c\/strong\u003e\u003cbr\u003e\n  A1: The card functions as the main circuit interface. It is responsible for scaling down operational high-voltage parameters and handling intermediate signal driving commands required by the system's power modules.\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ2: Can this board replace alternative RINT series boards like the RINT-6621C?\u003c\/strong\u003e\u003cbr\u003e\n  A2: No. While they belong to the same hardware interface family, distinct model numbers represent different power ratings, layout tolerances, and frame sizes. Always use the exact model specified by your drive manual.\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ3: Should software or parameter backups be performed before changing this board?\u003c\/strong\u003e\u003cbr\u003e\n  A3: Yes. It is highly recommended to upload and back up all drive configuration profiles via the control panel or drive software tool before swapping internal physical board sets.\n\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050870767748,"sku":"RINT-5611C","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/RINT-5611C-2.jpg?v=1783519997","url":"https:\/\/www.etowonauto.com\/tk\/products\/rint-5611c-main-circuit-connection-module-abb-drives","provider":"Etowon Auto","version":"1.0","type":"link"}