{"product_id":"ic693bem333-ge-fanuc-1mhz-dual-port-remote-fip-module","title":"IC693BEM333 GE Fanuc 1MHz Dual-Port Remote FIP Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc IC693BEM333\u003c\/strong\u003e is a specialized Remote FIP (Factory Instrumentation Protocol) Bus Expansion Interface Module designed for the GE Series 90-30 Programmable Logic Controller (PLC) architecture. Operating as a high-speed fieldbus communication gateway, this module provides seamless deterministic data exchange across industrial networks at a transmission speed of 1 MHz.\u003c\/p\u003e\n\n\u003cp\u003eEquipped with dual 9-pin D-type serial ports, the IC693BEM333 supports redundant or multi-drop FIP network topologies across maximum segment lengths of up to 100 meters per port. Weighing approximately \u003cstrong\u003e0.27 kg (0.60 lbs)\u003c\/strong\u003e, this IP20-rated module operates directly off the Series 90-30 backplane power supply, features 4 real-time diagnostic LEDs (CD1, TEN1, CD2, TEN2), and installs into any available I\/O slot in a Series 90-30 chassis (excluding Slot 1, which is dedicated to the CPU).\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Port FIP Communication:\u003c\/strong\u003e Features 2 x 9-pin D-type connectors supporting 1 MHz high-speed deterministic Factory Instrumentation Protocol (FIP) networking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostics:\u003c\/strong\u003e Built-in front panel LED array (CD1, TEN1, CD2, TEN2) provides immediate visual feedback for carrier detect and transmit enable status across both channels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Chassis Installation:\u003c\/strong\u003e Mounts into any open slot of a standard Series 90-30 baseplate (Slots 2 through 10) for direct backplane power and bus communication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Thermal Resilience:\u003c\/strong\u003e Engineered to operate reliably in control panel enclosures from 0°C to +60°C (32°F to 140°F) under standard IP20 environmental protections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGE Fanuc Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eFull Catalog Part Number\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIC693BEM333\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eModule Function\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eBus Expansion Module (Remote FIP Interface)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSeries 90-30 PLCs (Not supported on PACSystems RX3i)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFactory Instrumentation Protocol (FIP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eTransmission Rate\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1 MHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eSerial Port Interfaces\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2 x 9-Pin Sub-D Female Connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eMaximum Cable Distance\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e100 meters (328 feet) per port segment\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eNet Module Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.27 kg (0.60 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eChassis Slot Location\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eAny baseplate slot except Slot 1 (reserved for CPU)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003ePower Source\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eInternal power supplied via Series 90-30 backplane bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eDiagnostic Status Indicators\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4 LEDs (CD1, TEN1, CD2, TEN2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eIngress Protection Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIP20 (requires indoor control enclosure)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0°C to +60°C (32°F to 140°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Gap Calibration Guide\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChassis Slot Mounting:\u003c\/strong\u003e Align the module with the card guides in any Series 90-30 chassis slot (except Slot 1) and press firmly until seated on the backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePort Wiring \u0026amp; Distance Limits:\u003c\/strong\u003e Connect 9-pin Sub-D FIP network cables to Ports 1 and 2, keeping each cable segment under the 100-meter maximum length rule.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Protection:\u003c\/strong\u003e Install the chassis in an IP54 or NEMA-rated enclosure to shield the IP20-rated module from moisture, airborne dust, and conductive oil mist.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What does model designation IC693BEM333 represent?\u003c\/strong\u003e\u003cbr\u003e\nA1: GE Series 90-30 Bus Expansion Module (BEM) equipped with a 1MHz dual-port Remote FIP interface. (93 chars)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can the IC693BEM333 module be used in a PACSystems RX3i rack?\u003c\/strong\u003e\u003cbr\u003e\nA2: No, it is specifically designed for Series 90-30 baseplates and is not compatible with RX3i systems. (96 chars)\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Which slot should I install the IC693BEM333 into?\u003c\/strong\u003e\u003cbr\u003e\nA3: It can be placed in any open Series 90-30 baseplate slot except Slot 1, which is reserved for the CPU. (97 chars)\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050826432644,"sku":"IC693BEM333","price":118.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693BEM333.jpg?v=1785562286","url":"https:\/\/www.etowonauto.com\/tk\/products\/ic693bem333-ge-fanuc-1mhz-dual-port-remote-fip-module","provider":"Etowon Auto","version":"1.0","type":"link"}